I FOUND THE ROCK FALL WHILE I WAS MAKING MY WEEKLY EXAMINATIONS IN THE RETURN AIRCOURSE. I DON'T KNOW WHEN IT FELL. IT WAS WITHIN A 7 DAY PERIOD. THE FALL WAS A CONTINUING OF ANOTHER ROCK FALL . IT WAS BOLTED WITH 4' CONVENTIONAL BOLTS. IT FELL ABOUT 10' THICK, FOR 120' LONG.
Mackie J Coal Company IncMining Incidents in 2000
All MSHA-reportable accidents at Mackie J Coal Company Inc operations in 2000. Fatalities appear first.
- Fatalities in 2000
- 0
- Total incidents
- 5
- Year
- 2000
Top incident classifications
- 01FALL OF ROOF OR BACK4 incidents
- 02SLIP OR FALL OF PERSON1 incident
All incidents in 2000
Accident type, without injuries
Accident type, without injuries
ROCK FELL IN THE FIRST RIGHT BLEEDER FROM OUTSIDE. THE ROCKFELL BETWEEN THE BLOCKS OF COAL 2 BREAKS ABOVE SPAD 20. IT WAS ABOUT 30"" THICK AND 20' WIDE. IT DIDN'T BLOCK THE HAULWAY I TRAVEL. IT WAS BETWEEN THE 2 TRAVELWAYS UP THE BLEEDER.
Accident type, without injuries
ROCK FALL ABOUT 6 FT THICK AND ABOUT 45 FT LONG. FELL BETWEEN SPAD 890-891 IN THE RETURN ON AN OLD SECTION. IT WAS CRIBBED OFF ON EACH SIDE. IT WAS BOLTED WITH 5 FT BOLTS.
Accident type, without injuries
MINE ROOF FELL FROM #7 HEADING TO #6 INTERSECTION AND CAUGHT MINER BETWEEN 5 AND 6.
Over-exertion (Not Elsewhere Classified)
STEP ON SLAP OF CONCRETE AND TWISTED ANKLE.