While cleaning the clean air side of Silo 51 air slide, an employee found the slide choked and not flowing. EE used a short air lance to clear cement and restore flow. Cement blew back into EE's face, entering EE's right eye under EE's safety glasses. EE was sent to an eye doctor; no damage was found and antibiotic eye drops were prescribed. No lost time resulted. Returned to job.
Search the record
Every injury and fatality MSHA has on file. Filter by state, year, sector, classification, experience, or any keyword from the investigator's narrative.
- Total incidents
- 273,095
- Of which fatal
- 1,202
- Years on record
- 2000–2026
- Classifications
- 20
Alert me on this search
Email me when a new incident matches these filters. One confirmation email; unsubscribe anytime.
11 matching records
Showing all 11At the completion of a job on the Bypass Dust Collector the Production Coordinator was ensuring all valves for the system were secure. As they walked to the discharge valve on the bypass compartment (which was closed) a blast of dust came out from the Benetech inspection door. The material hit the employee in the face and head causing an injury to the left eye.
The employee was removing a sample from the pellet press machine when the sample cap contacted the control arm during extraction and was ejected from the machine striking the employee.
Employee was using air lance to dree frozen rock from a chute for several hours. Injured left shoulder due to repetitive work.
Miner was installing bolt on frame of conveyor holding head of bolt with right hand. As miner ran nut to tighten with an impact driver, the washer on the head of the bolt pinched miner's right thumb tip against the conveyor frame causing laceration requiring stitches to close.
The employee was using a cutting torch to remove corroded bolts from the synthetic gypsum system. After cutting 3 bolts the employee reoriented self to cut the 4th. This changed the direction that fumes would exhaust from the cutting. The employee felt dizzy and short of breath from the exposure and was issued prescription medication and restricted duty.
Employee was welding and got photokeratitis in both eyes when they lifted their welding hood. Employee received medical treatment beyond first aid.
While installing an electric motor on equipment I.D. 351-BE-10, the employee was standing on the outer casing of the bucket elevator to set the motor in place. The employees were using a metal beam to hoist the motor in place. The beam slipped and dislodged from its resting location and onto the floor decking. The employee fell onto the beam an injured chest.
While installing an electric motor on equipment I.D. 351-BE-10, the employee was standing on the outer casing of the bucket elevator to set the motor in place. The employees were using a metal beam to hoist the motor in place. The beam slipped and dislodged from its resting location and onto the floor decking. When the beam fell, it struck the employee in the upper torso.
While installing an electric motor on equipment I.D. 351-BE-10, the employee was standing on the outer casing of the bucket elevator to set the motor in place. The employees were using a metal beam to hoist the motor in place. The beam slipped and dislodged from its resting location and onto the floor decking. The beam struck the employees lower leg area causing the injury.
The employee was using an air lance while on a scissor lift. The scissor lift tipped over while the employee was in the basket. The impact caused the employee to suffer from broken bones in arm and pelvis.