Mining Incidents

Terry Eagle Coal Company operator

Controlled by M A Hanna Company
MSHA operator ID: P17164
Fatalities
1
Total incidents
70
Mines on record
7
Years on record
1985–1988

Top causes

Incident timeline

1988
10
1987
24 (1f)
1986
30
1985
6

Mines on record

Fatalities under this operator

1 recorded
June 17, 1987 WV · Coal roof bolter, rock bolter, pinner, mobile roof support operator (mrs) Fatality · ELECTRICAL
Terry Eagle Coal Company · Contact with electrical current

THE TRAILING CA6LE ON #2 BOLTER WAS DEFECTIVE IN THAT THE GROUND WIRE WAS INTO, A SPLICE IN THE CABLE. FOR SOME UNDETERMINED REASON THE CIRCUIT BREAKER DID NOT TRIP. WHEN THE VICTIM ATTEMPTED TO START THE M5CHINE, HE WAS ELECTROCUTED. THIS OCCURRED IN #2 ENTRY, ONE CROSS CUT OUTBY THE FACE.

Watch this operator

Email me when a new MSHA incident is filed at any Terry Eagle Coal Company mine.