B2-2 return area had a roof fall approx 350' long x 20' wide, unknown height. #2 entry from SS# 1688 to 100' inby SS# 1640. Roof Fall impeded travel in the return entries. Fall was reported at 8:35pm. Area was bolted with 6' fully grouted bolts. Area was laminated rock layers.
Wilson Creek Energy, LLCMining Incidents in 2019
All MSHA-reportable accidents at Wilson Creek Energy, LLC operations in 2019. Fatalities appear first.
- Fatalities in 2019
- 0
- Total incidents
- 3
- Year
- 2019
Top incident classifications
- 01FALL OF ROOF OR BACK2 incidents
- 02OTHER1 incident
All incidents in 2019
Accident type, without injuries
Absorption of radiations, caustics, toxic and noxious substances
Employee was riding on mantrip going to the section. Was bitten by a spider on the left forearm. Was given antibiotics on 12-27-19 for infection.
Struck by flying object
Fletcher Roof Bolter ATRS knocked down a rock from the roof. When the rock fell to the bottom it landed on another rock and broke apart. One of the smaller pieces flew up and struck the bolter helper in the chin. Employee was standing approx. 12' behind the last row of bolts. Employee received a cut on the lower lip/chin area which received 4 stitches.