IN #4 ENTRY IN 1 EAST AT 2ND X-CUT FALL WAS APPROX 30 FT LONG 18 FT WIDE 4 FT HIGH AT SPAD 429A NO SIGNIGICANT INTERUPTION OF VENTILATION WAS ENCOUNTERED
No 21 Coal
Registro de la MSHA sobre No 21 (ID de mina 1511725). Muertes, incidentes no mortales agrupados por año, operador y controlador actuales, y contexto de la mina.
Seguir esta mina
Avísenme cuando se presente un nuevo incidente de la MSHA en No 21.
- Muertes
- 0
- Incidentes totales
- 18
- Años en registro
- 1983–1985
- Último incidente
- Sep 1985
Incidentes reportables
18 en archivo1985 · 6 incidentes
IN 6 ENTRY IN NORTH MAINS AT 50 TH XCUT FALL WAS APPROX. 30FT LONG X 16 WIDE 3 6 HIGH AT SPAD 10499. NO SIGNIFICANT INTERUPTION OF VENTILATION WAS ENCOUNTERED.
INJURED AND CO-WORKER HAD PULLED THE ROOF DRILL INTO CROSSCUT TO INSTALL A CURTAIN BOARD. THE ROOF DRILL WAS PROTRUDING INTO THE HAULWAY WHEN A SHUTTLE CAR STRUCK THE DRILL, KNOCKING INJURED O FF OF SEAT.
#7 ENTRY IN 2 WEST AT 12TH X-CUT FALL WAS APPROX 75\ LONG 10\ HIGH OR MORE COULDN\T TELL. AT SPAD 10689 NO SIGNIFICANT INTERUPTION OF VENTILATION WAS ENCOUNTERED.
THE CONTINUOUS MINER HAD PULLED CABLE UP TO THE RIGHT SIDE TO CUT A CUT OF COAL.THE CABLE BECAME TANGLED IN TIMBERS.AS INJURED BENT OVER TO PUT TIMBER ON RIB,HE STATED HE FELT A PAIN IN HIS BA BACK.(HE DID NOT BEGIN LOSING TIME UNTIL 3-12-85).
IN 5 ENTRY IN NORTH MAINS AT 47 X CUT FALL WAS APPROX. 40 LONG 14 WIDE 4 HIGH AT SPAD 10494 NO SIGNIFCANT INTERUPTION OF VENTILATION WAS ENCOUNTERED.
1984 · 6 incidentes
INJURED WAS CLEANING BELT. AS HE TURNED TO PUT A SHOVEL OF GOB ON TAILPIECE, HIS FEET SLIPPED CAUSING HIM TO FALL BACK, STRIKING HIS BACK AGINST MINE FLOOR.
ROOF FALL IN #5 ENTRY IN NORTH MAINS. FALL WAS APPROX. 50\ LONG X 18\ WIDE X 4\ HIGH. 150\ OUTBY SPAD 10522 NO SIGNIFICANT INTERUPTION OF VENTIILATION WAS ENCOUNTERED.
IN #5 ENTRY IN 2 WEST FALL WAS APPROX 90X18X6 INBY SPAD 10687 NO SIGNIFIANT INTERUPTION OF VENT WAS ENCOUNTERED
INJURED WAS ATTEMPTNG TO PULL MINER CABLE OUT OF ROADWAY WHEN HE FELT A PAIN IN HIS BACK.
IN #2 ENTRY IN 2LT S.W. MAIN FALL WAS APPROX. 25 LONG 18 WIDE 3 1/2 THICK INBY SPAD 11782 NO SIGNIFICANT INTERUPTION OF VENTILATION WAS ENCOUNTERED.
ROOF FALL ON 65 FT INBY SPAD 10854 IN NO 5 ENTRY NO 49 X-CUT OF 2 WEST HEADINGS.FAL APPX 80\LONG X 18\WIDE X 5\HIGH.NO INTERRUPTION OF VENTILATION ENCOUNTERED.
1983 · 6 incidentes
IN NORTH EAST MAINS NO 3 HDG AT 51 XCUT AT STATION NO 10510 FALL WAS APPROX 24INX20FTX25FT
FALL OCCURRED AT FACE OF #7 ROOM AT INTERSECTION SW MAINS FALL WAS 18X18X6 HAD BEEN STOPED WE WERE NEAR OUTCROP NO SIGNIFICANT INTERUPTION OF VENT WAS ENCOUNTERED
IN SW MAINS HEADINGS APPROX 80\ LONG AND 20\ WIDE UP #7 HEADING WITH SPAD #11514 BEING CENTER ACROSS #7 HEADING APPROX. 20\ FROM SPAD 11515 TO 20\ FROM 11513
IN SW MAINS HEADING IN #1 HEADING 50FT INBY SPAD 11532 FALL WAS APPROX 42FTX40FT NO INTERRUPTION OF VENTILATION WAS ENCOUNTERED THE HEADINGS HAD BEEN STOPPED
IN SW MAINS HEADING IN 7 HEADING AT SPAD 11529 FALL WAS APPROX 3FTX20FTX90FT
IN SW MAINS HEAPING IN 8 HEADING AT SPAD 11530 FALL WAS APPROX 5FTX20FTX60FT