1ST WEST PANEL OFF OF 1ST SOUTH MAIN RETURN ROOMS 20'WIDE, 10'HIGH, 160'LONG.
Warrior Coal, LLCMining Incidents in 2001
All MSHA-reportable accidents at Warrior Coal, LLC operations in 2001. Fatalities appear first.
- Fatalities in 2001
- 1
- Total incidents
- 32
- Year
- 2001
Top incident classifications
- 01FALL OF ROOF OR BACK12 incidents
- 02HANDLING OF MATERIALS9 incidents
- 03POWERED HAULAGE3 incidents
- 04SLIP OR FALL OF PERSON3 incidents
- 05MACHINERY3 incidents
All incidents in 2001
2 A RETURN X CUT 18-22 #1 ENTRY 320' LONG 19' WIDE 7' HIGH. FOUND ON REG EXAM.
FALL IN #14 SEAM 2B 3RD NORTH MAIN X-CUT #16-#19, #1 ENTRY RETURN 300' LONG 18' WIDE 10' HIGH.
FALL AT #27 X-CUT FROM PORTAL SUPPLY RD INTERSECTION 18' BY 18' BY 7'.
95' LONB 19' WIDE 8' HIGH 3RD MAIN NORTH #7 ENTRY 35 AND 36 X CUT.
10' HIGH, 20' WIDE, 30' LONG. FACE OF #4 ENTRY, #2 UNIT.
ROCK FALL #4 ENTRY ON THE SECOND MAIN NORTH, #2 UNIT #11 SEAMOF COAL XCUT 20 SPAD #14+40. 10' H X 6' L X 25' W.
EE WAS LAST HEARD WITH A HAMMER MAKING REPAIRS TO THE CURTAIN IN THE FACE OF THE #4 ENTRY. AN ELMCO DIESEL SCOOP WAS BEING USED TO CLEAN UP AND HAUL COAL FROM A PREVIOUS ROOM SET UP TO THE ACT IVE MMU 0-001 UNIT AND DUMP IN THE ROTARY COAL FEEDER. THE COAL FEEDER WAS SHUT DOWN AND WHILE REPAIRS WERE BEING MADE THE SCOOP OPERATOR WAS INSTRUCTED TO CHANGE HIS HAULAGE ROUTE AND DUMP T
SHE SAID SHOVELING ON BELT LINE AREA MADE HER BACK HURT.
EE WAS GETTING OFF OF THE D-5 DOZER, WHEN HE SLIPPED ON THE TRACK, HOLDING ON TO THE HAND RAIL, PULLING HIS SHOULDER OUT OF PLACE.
WHILE PUTTING SEALANT ON BRATTICE, VICTIM GOT PLASTER IN EYE.
VICTIM SAID HE STRAINED BACK WHILE HANGING ELECTRICAL CABLE.
VICTIM WAS HAND DUSTING FACE AREA WHEN ROCK FELL ON HIM, KNOCKING HIM TO GROUND AND FRACTURING FINGERS.
MOVED MINER CABLE & STRAINED LOWER BACK REPORTED 8-24-01 2:00 PM.
VICTIM WAS RIDING ON MANTRIP WHEN A PIECE OF GOBROCK FELL & STRUCK HIM ON FACE.
GOT SLIVER OF STEEL IN HAND, REMOVED BY PHYSICIAN 1 WK LATER.
EMPLOYEE WAS PUTTING UP PINS, STARTED PICKING UP BOARDS AND STRAINED LOWER BACK.
MOVING POWER ON THE UNIT, PULLING THE POWER CABLE, WHEN HE FELT A SHARP PAIN IN HIS LOWER BACK AND LEGS.
WHILE DRIVING TO WORK EE RAN OFF RD ON CO. PROPERTY. HE SAID HE INJURED NECK AS PER CMIS. SUBMITTED RESULT OF AUDIT - TERMINATE CITATION 7648085.
EE SAID HE TRIPPED ON S0ME STEPS LEADING INTO BATHHOUSE BECAME REPORTABLE 8/27/01
EE WAS SHOVELING COAL FROM MINE FLOOR, CALLED AND REPORTED THE FOLLOWING DAY OF PAIN IN ARM AND SHOULDER.
EMPLOYEE WAS INSTALLING ROOF BOLTS AND SAID HE STRAINED SHOULDER.
CUTTING COAL, BIT CAME OFF OF THE HEAD, HITTING EE IN HIS RIGHT ARM.
HELPING PIN OPERATOR IN #4 ENTRY ON #2 UNIT AND ROCK FELL HITTING HIS LEFT WRIST AND ELBOW, KNOCKING HIM DOWN, HURTING HIS RIGHT KNEE ALSO.
EE WAS CROSSING UNIT BELT TO PUT UP POWER FOR THE UNIT AND AFTER CROSSING BELT EE HIT HIS LEFT THIGH ON A BELT FRAME LOOP.
EE WAS WORKING ON SCOOP, AND A PIECE OF ROCK FELL OUT, STRIKING ON HIS SHOULDER.
FRACTURE & LACERATION OF MIDDLE FINGER LEFT HANDTOOL BOX LID FELL ON FINGER.
ALLEGED ACCIDENT OCCURRED WHEN VICTIM SAID HE HIT HOLE OR BUMP IN RD. FINISHED SHIFT.