ROOF RODE THRU BREAKER TIMBERS ON PILLAR LINE APPROX 80'. ROCK CAUGHT ABOUT 6' OF BACK OF PINNER
No 1 Mine Coal
Seguir esta mina
Avísenme cuando se presente un nuevo incidente de la MSHA en No 1 Mine.
- Muertes
- 0
- Incidentes totales
- 23
- Años en registro
- 1992–1996
- Último incidente
- Jan 1996
Incidentes reportables
23 en archivo1996 · 2 incidentes
ROOF FALL IN ABANDONED ARE A MINE. DID NOT BLOCK ANY TRAVELWAY OR AIRWAY. FALL WA IN AN OLD PANEL MADE WEEKLY BY MYSELF.
1995 · 7 incidentes
ROCK APPROX. 42" THICK /6' WIDE /20' LONG FELL BETWEEN TWO HILL SEAMS. NO DAMAGE, THIS ENTRY HAD BEEN DROPPED.
A PREVIOUSLY REPORTED ROOF FALL WHICH HAD BEEN DANGERED OFF CONTINUED THRU INTERSECTION AND ACROSS BREAK. NO BLOCKAGE OF AIRWAY OR TRAVELING SINCE THIS AREA WAS ALREADY DANGERED OFF.
PIECE OF SANDSTONE APPROX 4 FT THICK, 8 FT WIDE, 20 FT LONG, FELL FROM MOUNTAIN SEAM, NO DAMAGE OR IMPAIRMENT.
ROOF FALL AT 41/2FT BOLTS INSTALLEDWERE 4FT CONVENTIONAL THIS AREA IS TRANSITIONAL IN THAT SLATE TOP IS RUNNING OUT & SANDSTONE TOP IS BECOMING IMMEDIATE ROOF AS OF 4:00PM 06-07-95 THIS AREA W ILL NO LONGER BE MINED MOVING SECTION
ROOF FALL IN INTERSECTION IN FRONT OF #3 SEAL. FALL WAS APPROX. 60' LONG, 10' WIDE, 3'-4' HIGH ON INTAKE SIDE. VENTILATION WAS NOT AFFECTED. NO EQUIPMENT WAS INVOLVED.
NO ONE INJURED IN ROOF FALL. FALL IN BLEEDER LINE FOUND WHILE I.NAME WAS GATHERING UP EXCESS BRATTICE BLOCK LEFT ON. 10,428 CFM AIR GOING ACROSS TOP OF FALL.
ROOF FALL 8 BREAKS LEFT OF SPAD #8003 FALL WAS APPROX 60FT LONG 20FT HIGH 6 TO 8FT HIGH LOCATED IN RETURN VENTILATION WAS NOT AFFECTED NO EQUIPMENT INVOLVED
1994 · 6 incidentes
PULLING MINER CABLE, AND PULLED LOWER BACK AREA.
LIFTING BELT TO HELP PUT IN BOTTOM ROLLER AND PULLED BACK MUSCLE.
EE WAS GOING BACK TO OPERATE SHUTTLE CAR AFTER HIS DINNER BREAK, FELT SOMETHING POP IN HIS KNEE WHILE WALKING.
ROOF FALL ABOVE ANCHORAGE OF BOLTS ONE BREAK INBY SPAD NO. 51. 20' WIDE, 20' LONG, 6' THICK. LOCATED ON INTAKE. DID NOT BLOCK ARM. HAVE TO CLEAN UP ALTERNATE ROUTE FOR A TRAVELABLE ESCAPEWAY. FALL FOUND ABOUT 3 A.M.
REPORT RECEIVED ON OCCUPATIONAL DISEASE OF COAL WORKERS' PNEUMOCONIOSIS.
ROCK FALL 1 BREAK INBY SPAD NO. 32 IN RETURN. DID NOT CLEAN UP FALL. TIMBERED AND CRIBBED AND DANGERED OFF. FOUND DURING PRESHIFT 4-11-94 DAY SHIFT.
1993 · 7 incidentes
HIT HOLE IN ROADWAY STRUCK HEAD ON CANOPY CUTTING FOREHEAD.
ROCK FALL IN OLD NO. 8 HEADING OUTBY WORKING SECTION 40 FT LONG 12 FT WIDE 4 1/2 TO 5 FT THICK FELL ON INTAKE SIDE DID NOT AFFECT AIRFLOW DONT INTENDE TO CLEAN UP.
PULLING ROCK OFF OF BELT SLIPPED AND FELL ON HIP EMPLOYEE WORKED UNTIL THE 15TH OF NOV. THEN DECIDED TO GOT TO DOCTOR.
DRAW ROCK FELL FROM TOP STRIKING EMPLOYEE ON LEFT SHOULDER KNOCKING HIM TO FLOOR AND LANDING ON HIS RIGHT HIP.
ROOF FALL AT CROSSCUT 51 ENTRY NO 6 AND NO 7 IN RETURN APPROX. 5 FT THICK 20 FT WIDE 55 FT LONG DID NOT BLOCK RETURN. NO PLANS TO CLEAN UP AT THIS TIME.
RAN SHUTTLE CAR OVER LUMP OF COAL AND BOUNCED HEAD AGAINST CANOPY INJURING NECK.
REPORTED CASE OF BLACK LUNG.
1992 · 1 incidente
EE WAS HELPING MOVE MINER CABLE PULL ROPE WAS HOOKED TO A PIECE OF PINNEN STEEL THE PIECE OF PINNEN STEEL GOT UNDER PRESSURE AND CAME LOOSE STRIKING EE IN LEFT LEG.