2 de octubre de 2009
MN · Metal/No metálico
Operador de bulldozer, Operador universal, Operador de equipo pesado, Ingeniero operador
ELÉCTRICO
Mark Sand & Gravel Co. · Contacto con corriente eléctrica
Light rain was falling, standing water, wet equipment, electrical wiring was color coded incorrectly and wired wrong in the junction box, the ground lead was wired into the buss bar and caused the equipment frame to become energized. Employee set up a metal ladder to inspect equipment and received electrical shock.