THIS IS A CONTINUATION OF A FALL THAT FELL ON 11-25-98 THAT WAS CLEARED AND BOLTED UP TO THE POINT WHERE THE FALL STARTED ON 12-5-98.
Target No 1 Mine Coal
Seguir esta mina
Avísenme cuando se presente un nuevo incidente de la MSHA en Target No 1 Mine.
- Muertes
- 0
- Incidentes totales
- 139
- Años en registro
- 1983–1998
- Último incidente
- Dec 1998
Incidentes reportables
139 en archivo1998 · 11 incidentes
ROOF FALL IN INTERSECTION OF #4 HEADING #2 BLOCK OF 6 LEFT HEADING. APPROX 18'WIDE,25'LONG,12'HIGH. HEADING 2N TO FALL HAS BEEN REBOLTED WITH 6' RESIN BOLTS.
ROOF FALL 24' LONG, ONE FULL CUT FRO BOLTS TO BOLTS, 15' WIDE, 6' HIGH. THE FALL OCCURRED AFTER THE MINER CAME OUT OF THE CUT & BEFORE THE BOLTERS WENT IN. THE FALL WAS IN THE 5 LEFT 2ND LEFT SECTION NO. 3 XCUT BETWEEN 2 EAST & 3 ENT.
BENT OVR TO LIFT A CONVEYOR MOTOR HERNIATED DISC IN LOWER BACK
FALL OF ROOF STARTED APPROX 30' INBY 15 CROSSCUT IN 6 ENTRY 5 LEFT SECTION LMMU 002-0. FALL CONTINUED TO APPROX 20' INBY 16 CROSSCUT IN 6 ENTRY. FALL MEASURES APPROX 90'L, 17'W, 7'H. ORIGINAL SUPPORTS WERE 4' & 6' RESIN BOLTS. WATER IS STILL COMING OUT OF ROOF.
FALL OF ROOF WAS DISCOVERED ON PRE-SHIFT. FALL IS IN #7 ENTRY 14 BLOCK SECTION MMU 002-0. NO EQUIPMENT OR PEOPLE INJURED. FALL HAS BEEN DANGERED OFF. FALL MEASURES 14 X 15 X 6' HIGH LOTS OF WA TER COMMING THROUGH THE ROOF.
FALL OF ROOF WAS DISCOVERED ON SECTION PRE SHIFTEXAMINATION. THE FALL IS IN 7 ENTRY 13 X CUT OF 5 LEFT SECTION MMU 002-0. NO EQUIPMENT OR PEOPLEINJURED. AIR FLOW MAY HAVE A SLIGHT DECREASE. FA LL HAS BEEN DANGERED OFF AND MSHA NOTIFIED. FALLMEASURES APPROX 16' X 16' X 7' HIGH. PREVIOUS SUPPORT WAS 4' AND 6' RESIN BOLTS.
RUNNING SHUTTLE CAR OUT OF FACE. RIGHT LEG WAS OUT OF CAB BETWEEN SHUTTLE CAR AND RIB, 5 CROSSCUT IN 6 13 BLK 5 LEFT SECTION BROKEN BONES IN ANKLE.
FALL OF ROOF MEASURING 40' X 16' X 6' HIGH IN THE N. 2 X-CUT NO. 6 ENTRY OF 5 LEFT SECTION. FALL WAS DISCOVERED AFTER PRE-SHIFT EXAM BY MINE EXAMINER -------. AREA WAS DANGERED OFF & POSTED. E XAMINER HARD FALL OCCUR.
FALL OF ROOF AT #7 BLOCK INTERSECTION OF 4 LEFT 7 BUTT BLEEDER ENTRY FOUND DURING WEEKLY EXAM.
FALL OCCURRED #6 ENTRY, 4 BLOCK SHAFT SECTION. MEASURED APPROX. 16' WIDE, 40' LONG, 6' HIGH. FALL WAS FOUND ON PRESHIFT EXAM BY FIREBOSS. POSSIBLE CABES ARE PITTSBURGH GOB & SLIP. NO INJURES O R EQUIPMENT DAMAGE.
1997 · 10 incidentes
FALL OF ROOM IN #3 ENRTY, #33 X-CUT, WEST MAINS SECTION. FALL MEASURED APPROX. 18' X 18' X 6' HIGH. FALL WAS IN INTERSECTION. NO INJURIES OR EQUIPMENT DAMAGE.
ROOF BROKE OFF ABOVE BOLTS.
ROOF BROKE OFF ABOVE ROOF BOLTS.
ROOF FALL APPOX 30'LX20'WX5'H IN #3 ENTRY, #13 CROSS CUT PARALLEL TO #3 BELT (WEST MAINS)> THE FALL WAS DISCOVERD DURING PRE-SHIFT EXAMINATION.
ROOF FALL AREA ON 3 MAIN HAULAGE 27 RM.
AREA FROM #4 HEADING, LAST OPEN XCUT TO #5 HEADING ON 4-LEFT SECTION CAVED IN.
FALL MEASURED APPROX. 18' WIDE BY 30' LONG BY 10' HIGH AT 13 BLOCK, 6 ENTRY OF THE 4 LEFT 6 BUTT WEST PANEL.
ROOF FALL ON #3 MAIN HAULAGE AT #12 ROOM MAINS WEST PARALLEL TO #3 BELT. APPROX 20' LONG, 18' WIDE, 8-10' HIGH. THERE WERE NO INJURIES, HAD SOME LOSS OF VENTILATION DUE TO WHERE THE FALL OCCUR RED BUT AMPLE AMOUNT OF AIR STILL FLOWING 0ON SECTION
#6 ENTRY ROOM #23 INTERSECTION ONE FT ABOVE 4 FTBOLT ANCHORAGE. DISCOVERED 11-12PM PRE-SHIFT DANGERED OFF & POSTED ENTRY TOO FALL AREA
AREA FROM #2 HEADING AT 14 CROSSCUT ON 4 LEFT 5 BUTT WEST PANEL TO #8 HEADING AT 14 CROSSCUT ON 4 LEFT 4 BUFF WEST PANEL CAVED IN.
1996 · 5 incidentes
ROOF FALL WAS DISCOVERED ON WEEKLY EXAMINATION OF RETURNS AT #2 ENTRY #13 X-CUT LT RETURN OF M WEST SECTION.THE FALL MEASURES APPROX 18' WIDE BY 55' LONG.THERE WERE NO INJURIES AND VENTILATION OF THE MINE WAS NOT INTERRUPTED THE FALL IS APPOX 6' HIGH.
ROOF FALL ON 2 BELT 24" HIGH 15'X15' THERE WERE NO INJURES AND VENTILATION WAS NOT EFFECTED.
ROOF FALL ON #2 BELT 24" HIGH. 15'X15'. THERE WERE NO INJURIES AND VENTILATION WAS NOT EFFECTED.
THERE WAS A ROOF FALL ON 5 HAULAGE 2RM PARALLEL TO 2 BELT APPROX. 35'L X 17'W X 7'H. THERE WERE NO INJURIES AND VENILATION OF THE MINE WAS NOT EFFECTED.
THERE WAS A ROOF FALL ON 5 HAULAGE 2 RM PARALLED TO 2 BELT APPROX. 35' LONG 17' WIDE & 7' HIGH. THERE WAS NO INJURIES AND VENTILATION OF THE MINE WAS NOT AFFECTED.
1995 · 1 incidente
AN AREA 17' X 75' DETERIORATED ABOVE THE ANCORAGE OF THE PREVIOUSLY BOLTED MINE ROOF #3 ENTRY 25-76 CROSS CUTS ALONG #1 BELT ALLOWING TOP TO FALL.
1994 · 5 incidentes
DETERIORATING ROOF CONDITION ABOVE ANCHORAGE POINT UNDERLYING STRATA NOT ADEQUATE TO SUPPORT IMMEDIATE ROOF
HE TURNED IN THE 21 SC SEAT TO CHECK THE FEEDER AND FELT PAIN IN LOWER BACK RIGHT SIDE.
HE HAD A NORMAL WORKDAY HE DID NOT NOTICE ANYTHING UNSUAL UNTIL SHOWERING AT THE BATHHOUSE. HE FELT A LUMP IN THE GROIN AREA.
HE WAS LIFTING ROCKDUST BAG, WHEN HE FELT PAIN IN HIS LEFT SIDE.
WHILE SHOVELING BELT ON HIS KNEES HE FELT PAIN IN HIS LEFT KNEE HE SAID HE HAD PAIN OFF & ON IN FOLLOWING DAYS &WANTED TO GET MEDICAL ATTENTION 02-25-44
1993 · 4 incidentes
WHILE INJURED WAS SETTING POSTS HE LIFTED POST & EXPERIENCED PAIN IN LOWER BACK
ON A BELT MOVE, HE WAS LOADING BELT STRUCTURE AND FELT PAIN IN LOWER BACK, LEFT SIDE.
THREE FALLS OF ROOF OCCURRED IN THE #8 ENTRY BETWEEN #4 CROSSCUT & #8 CROSSCUT ALONG 3BELT THE FALLS MEASURE APPROX #1 6FTHIGHX18FTWIDEX50FTLONG #2 6FTHIGHX18FTWIDEX64FTLONG & #36FTHIGHX18FTWI DEX50FTLONG
WHILE HANGING 4160 HIGH VOLTAGE CABLE INJURED FELT PAIN IN LOWER BACK.
1992 · 6 incidentes
WHILE PULLING CABLE OFF OF THE BOLTER THE INJURED FELT PAIN IN LOWER BACK
A FALL OF ROOF OCURED IN THE 3 LEFT AREA #6 ENTRY #29 CROSSCUT BLEEDER APPROACH. THE FALL FROM 8' TO 18' WIDE AND FROM 2.5' TO 4' HIGH.
AFTER MINING THE FINAL PUSH AND WHILE BACKING OUT THE MIENR BROKE DOWN. THIS CAUSED IT TO BE COVERED UP IN A ROOF FALL. THE CONTINUOUS MINER WAS COVERED FOR APPROX 6' OPPOSITE THE OPERATOR SI DE TO 10' ONT HE OPERATOR'S SIDE BY 10' OF MATERIAL. TEH FALL OCCURED 4 LEFT 2 ENTRY 17 X-CUT.
10613L OF ROOF OCCURRED IN THE 4LEFT SECTION IN #3 ENTRY #20 CROSSCUT THE FALL IS APPROX 68' LONG X18' WIDE X10' HIGH AT ITS HIGHEST POINT.
96660FALL 4 LEFT SECTION #5 ENTRY #16 X-CUT #6 BELT APPROX 4' HIGH 18' WIDE 68' LONG.
10613L OF ROOF OCCURED INT HE 4 LEFT SECTION #1 ENTRY #19 CROSSCUT INTERSECTION. THE FALL IS APPROXIMATELY 22' WIDE X 25' LOGN X 5' HIGH. THE FALL WAS INVESTIGATED BY EMPLOYEE.
1991 · 6 incidentes
SHOVELING UNDER BELT PAIN IN LOWER BACK
A FALL OFF ROOF OCCURRED IN THE 3 LEFT SECTION #4 ENTRY #3 INTERSECTION ALONG #4 BELT. THE FALL IS APPROXIMATELY 50' LONG X20' WIDE X4' HIGH.
FALL OF ROOF OCCURED IN #4 ENTRY #26 CROSSCUT #1 BELT INTERSECTION. FALL IS APPROX 16' LONG X 15' WIDE X4' HIGH.
LIFTING OWENS CONV. DRIVE SHAFT FROM WORK BENCH TO FORKLIFT. FELT PAIN IN LOWER BACK.
LIFTING TOOL BOX FROM RAMCAR TO FLOOR. FELT PAIN IN LOWER BACK.
PIECE OF ROCK FELL STRIKING INJURED ON BACK OF LEFT CALF CAUSING CONTUSION OF CALF
1990 · 17 incidentes
A FALL OF ROOF OCCURRED IN THE 4 LEFT SECTION #4 ENTRY INBY #3 CROSSCUT.THE FALL OCCURRED FROM THE LAST OPEN CROSSCUT TO WITHIN 20' OF THE FACE.THE FALL IS APPROXIMATELY 4' HIGH X18' WIDE X35' LONG.
A FALL OF ROOF OCCURRED ALONG #1 BELT #26 X-CUT#5 ENTRY. THE FALL IS APPROX. 4' TO 5' HIGH X 18' WIDE X 40' LONG.
A FALL OF ROOF OCCURRED IN THE 3 LEFT SECTION IN #4 ENTRY #1 TO #2 CROSSCUT ALONG #4 BELT. THE FALL IS APPROXIMATELY 5' HIGH X 18' WIDE X 50' LONG.
A FALL OF ROOF OCCURRED ALONG #1 BELT #28 CROSSCUT #6 -#7 ENTRY. THE FALL IS APPROX. 50' LONG X 18' WIDE X 5' HIGH.
FALL OF ROOF OCCURRED IN 4 LEFT SECTION IN #4 ENTRY #7 CROSSCUT. FROM FACE OUTBY 63' FALL IS APPROX 63' LONG X 18' WIDE X 4' HIGH.
A FALL OF ROOF OCCURED IN THE 4 LEFT SECTION ALONG #7 BELT IN #2 ENTRY #4 CROSS CUT INBY TO FACE. THE FALL IS APPROXIMATELY 180' LONG X 18' WIDE X 4' TO 5' HIGH.
INJURED REMOVED FULL OIL CAN 5 GAL OFF OF GOLF CART WEIGHT OF CAN JERKED ARM DOWN WHILE TURNING FELT PAIN I LOWER BACK.
A FALL OF ROOF OCCURRED IN THE 4 LEFT SECTION ALONG #7 BELT 0 ENTRY #5 CROSSCUT. THE FALL IS APPROXIMATELY 60' LONG X 18' WIDE X 6' HIGH.
WALKING THRU WATER STEPPED ON SLATE TWISTED R KNEE
FALL OF ROOF OCCURED IN 4 LEFT SECTION ALONG #6 BELT #21 CROSSCUT FROM #1 TO #3 EN TRIES. FALL IS APPROX 200' LONG X 17' WIDE X 4' HIGH.
A FALL OF ROOF OCCURRED IN 4LEFT SECT.IN #1 ENTRY #3 TO #5 CROSSCUTS ALONG #6 BELT THE FALL IS APPROX 200FT LONGX18FT WIDEX5FT HIGH
FALL OF ROOF OCCURRED IN 4 LEFT SECTION ALONG #6 BELT AT #17 X-CUT FROM #1-#2 ENTRY.FALL IS 18' X 82" IN AREA X 5'HIGH.
A FALL OF ROOF OCCURRED IN #3 ENTRY #23 CROSS CUT ALONG #1 BELT THE FALL IS APPROX. 18'X18'X4' HIGH.
FALL OFF ROOF OCCURRED 3 LEFT BLEEDERS IN #1 ENTRY #30 X-CUT INTERSECTION.FALL IS 18 X 18 X 4'H
JUMPED FROM FORKLIFT.
WHILE INJURED WAS TYING CABLE THE WIRE BOUNCED FROM INJUREDS HAND AND STRUCK LEFT EYE.
ICY OUTSIDE. THE INJURED SLIPPED AND FELL AND HIT TAILBONE ON PIECE OF COAL CAUSING SEVERE PAIN.
1989 · 17 incidentes
WHILE INJURED WAS ROOF BOLTING, ROCK FAULT IN RIB ROLLED OUT STRIKING INJURED IN ANKLE.
INJURED WHILE INSTALLING OUTSIDE BOLT OF BOLTING PATTERN WAS POSITIONED IN TIGHT QUARTERS. INJURED AFTER DRILLING HOLE DROPPED THE DRILL HEAD ONTO HIS OWN FOOT. SUFFERED CONTUSIONS ON TOP OF LEFT FOOT.
FALLOF ROOF OCC IN 3 ENTEY 29 CROSS CUT INTERSECTION ALONG 1 BELT THE FAALL IS 18'W 18'L 8'HIGH
A FALL OF ROOF OCCURRED IN 3LEFT SECTION BLEEDER AT #1 ENTRY #10 CROSSCUT THE FALL IS APPROX 18FT WIDE & OF UNKNOWN HEIGHT AND LENGTH
INJURED WAS ALIGNING BELT,SLIPPED AND FELL HURTING HIS LOWER BACK.
A FALL OF ROOF OCCURRED IN THE 3 LEFT SECTION #4 ENTRY #9 CROSSCUT ALONG #4 BELT. THE FALL APPROX. 20' X 20' X 6' HIGH.
WHILE WALKING INJUIRED STRUCK HEAD ON BELT HANGER.
WHILE MOVING FROM ONE SIDE OF SLATE BELT TO THE OTHER SIDE,THE INJURED SLIPPED AND FELL ON THE DGE OF CONCRETE SLAB.
WHILE TIGHTENING UP ROOF BOLT PIECE OF SLATE FELL STRIKING INJURED ON UPPER LEFT FOREARM.
WHILE LIFTING A POST INJURED PULLED MUSCLE IN LOWER BACK
WHILE WALKING ALONG #2 DRIVE & AROUND #1 TAILPIECE INJURED SLIPPED ON THE MUDDY BOTTOM & FELL INJURED RT LEG WAS BROKEN IN THE FALL
A FALL OF ROOF OCCURRED IN #5 ENTRY CROSS CUT TO #O CROSSCUT. THE FALL IS APPROX. 60 FEET LONG, 1, FEET WIDE, 5 FEET HIGH.
GETTING OFF THE FRONT END LOADER STEP ON A PIECE OF COAL AND TURNED HIS ANKLE.
AFTER LOADING ONE SHUTLE CAR OF THE LAST LIFT OF THE SECOND SHORT SIDE FENDER,THE ROOF SUDDENLY AND WITHOUT WARNING FELL.THE CONTINUOUS MINER WAS COVERED FOR APPROXIMATELY 14'.THE MATERIAL WAS 10' HIGH THE FALL OCCURRED IN #4 ENTRY #2 CROSSCUT 3 LEFT SECTION.
A FALL OF ROOF OCCURRED IN 3 LEFT SECTION A LOMG #6 BELT #5 TO #6 ENTRY #10 CROSSCUT.THE FALL STARTED AT THE SECTION GOB AND TRAVELED THRU THE CROSSCUT TO THE SOLID RIB .THE FALL IS APPROXIMAT ELY 82' LONG X14' WIDE X4' HIGH.
INJURED TWISTED LEFT KNEE, STEPPED IN HOLE WHILE WALKING PASSED ROOF BOLTER.
AFTER LOADING 1 SC OFFTHE LAST LIFT OF THE SECOND FENDER THE ROOF STARTED TO WORK AS THE MINER WAS BACKING OUT THE ROOF FELL COVERING APPROX 10 FTOF THE HEAD OF THE MACHINE THE MATERIAL WAS AB OUT 10 FT HIGH THE FALL OCCURRED IN # 5 ENTRY #9 CUT
1988 · 15 incidentes
WHILE TRAMMING A BATTERY POWERED TRACTOR TRAILER INJURED RAN OVER 2 CONCRETE BLOCKS CAUSING THE TRACTOR TRAILER TO BOUNCE THE SUDDEN RISE AND FALL CAUSED INJURY TO THE OPERATOR LOW BACK
A FALL OF ROOF OCCURRED IN #8 ENTRY OF MAINS WEST. THE FALL BEGAN ON THE INBY END OF #7 CROSSCUT AND EXTENDS TO THE OUTBY END OF #8 CROSSCUT. THE FALL IS APPROX. 75' LONG X 18' WIDE X 4' IN HE IGHT.
WHILE PULLING ROCK DUSTER OFF SCOOP BUCKET INJURED PULLED MUSCLE IN RIGHT SHOULDER.
A FALL OF ROOF OCCURRED IN 3 LEFT SECTION THE FALL IS IN THE #3 ENTRYBELT #6 BELT.THE FALL BEGAN IN #4 INTERSECTION AND EXTENDED TO MID BLOCK (INBY) TOWARDS #5 INTERSECTION THE FALL IS APPROX 60' LONG X 18' WIDE AND 4'TO 5' HIGH.
WHILE PULLING MINER CABLE INJURED FELT PAIN IN LOWER RIGHT BACK.
WHILE LIFTING WHEEL UNIT ONTO CART FELT BACK PAIN IN LEFT SHOULDER
WHILE MAKING UP BOLT HOLES PIECE OF ROCK FELL FROM ROOF STRIKING INJURED ON R FOOT
WHILE PULLING FEEDER CABLE, CABLE BECAME TANGLED CAUSING PLUG TO BE PULLED FROM INJUREDS HAND. AS PLUG SLID THROUGH INJUREDS HANDS, SKIN ON TIP OF MIDDLE FINGER ON RIGHT HAND WAS TORN OFF.
WORKERS (INCLUDING INJURED) WERE DISMANTLING 4" WATER LINE WITHOUT BLEEDING PRESSURE OFF. LINE BURST, THROWING COAL AND DIRT INTO THE EYES OF THE INJURED.
WAS WALKING TO ANSWER PH ONE UNDERGROUND INJURED FORGOT TO DUCK AT LOW ROOF AREA STRIKING HEAD AGAINST ROOF BOLT. IMPACT CAUSED INJURY TO NECK.
INJURED WAS WALKING FROM MANTRIP STEPPED ON ROCK & FELT PAIN
WHILEINJURED WAS ALKING HE STRUCK HEAD AGAINST ROOF.
INJ WAS LIFTING AND PULLING MINER CABLEE WHEN HE FELT SUDDEN PAIN IN MIDDLE OF BACK
WHILE INJURED WAS TRAMMING GOLD CART LOCKWARD CANT STRUCK A PARKED SHUTTLE CAR ON HOUSEING JARING.
A FALL OF ROOF 2CCURED IN THE MAINS WEST SECTION ALONG 3 BELT. THE FALL IS IN 1 ENTRY STARTING MIDWAY BETWEEN AND CROSSCUT AND EXTENDING INBY TO 12 CROSSCUT. IT THEN TURN 90 FROM 1 ENTRY TO MI D POINT BETWEEN32 TO 3 ENTRY THE FALL IS APPROX. 335 LONG X 18 WIDE X 5 IN HEIGHT.
1987 · 10 incidentes
WHILE INJ WAS H5NGING HIGH VOLTAGE CABLE HE EXPERIENCED PAIN IN MIDDLE OF BACK
WHILE PUTTING T2OLS AWAY INJURED STRAIGHTENED UP STRUCK HEAD AGAINST ROOF.
FALL OF ROOF OC7URRED IN MAINS WEST SECTION #3 BELT #5 CROSSCUT #5ENTRY 20 FT INBY LINE OF RIB TO #3 ENTRY 40 FT INBY LINE OF RIB FALL IS APPROX 75X18X7
INJURED WAS BEN8ING OVER MOVING MINER CABLE WHEN HE FELT PAIN IN LOWER BACK.
ROOF FALL OCCUR9ED IN #5 ENTRY #4 X-CUT ALONG #2 BELT.FALL WAS AT ANCHORAGE POINT 50'LONG.
A FALL OF ROOF 2CCURED IN 1 LEFT BLEEDER 8 ENTRY 11 INTERSECTION THE FALL IN APPROX. 18X40 AND ABOUT 4 TO 5 INHEIGHT A CLAY VEIN WAS PRESENT.
WHILE CHANGING 8EATS IN SHUTTLE CAR INJURED WAS EATING AN APPLE, AND HIT HIS BACK IN HANDLE CAUSING HIM TO INHALE, CAUSING APPLE TO GO INTO RIGHT LUNG.
INJURED WAS INS7ALLING ANCHOR BOLTS IN THE MINE FLOOR WITH A HAND HELD HYD. DRILL.AFTER THE HOLE WAS FINISHED AND WHILE PULLING THE AUGER OUT OF THE HOLE, THE INJURED FELT A SHARP PAIN IN HIS LOWER BACK. 3
WHILE INJURED W5S DISCONNECTING THE CHARGE ON THE RAM CAR, HE SLIPPED AND FELL ON THE SURFACE ON A PIECE OF ICE TWISTING HIS ANKLE.
A ROOF FALL OCC6RRED IN MAINS WEST SECTION IN 5 ENTRY 2 CROSSCUTS FALL IS APPROX 40X20X5
1986 · 5 incidentes
ROOF FALL OCCUR9ED IN #1 ENTRY ALONG #1 BELT LINE BETWEEN #24 AND #25 X-CUTS.FALL 18' X 100 IN ARE AND 4'HIGH.
FALL OF ROOF OC6RRED IN THE 2 LEFT SECTION AT 3 ENTRY BETWEEN #4 AND #5 CROSSCUTS THE FALL IS APROX 18X38X10
A ROOF FALL OCC6RRED IN 2 LEFT SECTION AT #1 X-CUT #2 ENTRY INTERSECTION FALL IS APPROX 18'X30' IN AREA & 6' IN HEIGHT.
ROOF FALL OCCUR9ED IN THE 2 LEFT SECTION AT #6 CROSS CUT #5 ENTRY INTERSECTION THE FALL IS APPROX 18X30 AND ABOUT 4 FT IN HEIGHT
INJURED WAS BUI5DING A STOPPING. WHILE REACHING FOR A CONCRETE BLOCK A PIECE OF ROCK DISLODGED FROM ROOF AND STRUCK INJURED ON RIGHT FOREARM
1985 · 14 incidentes
WHILE LIFTING C9IB BLOCKS OUT OF RAM CAR AND SETTING CRIB INJURED FELT PAIN IN LEFT FORE ARM
WHILE PULLING CABLE, HE SLIPPED ON COAL AND TWISTED AND PULLED MUSCLE IN LOWER BACK.
AFTER FINISHING THE FIRST LIFT OF THE FIRST FENDER OF THE BLOCK. THE ROOF AND WITH OUT WARNING FELL THE MINER WAS BACKING OUT AT THE TIME THE MINER WAS COVERED FROM THE CUTTER BOOM HINGE POINT FORWARD WITH FROM 10 TO 15 FEET OF ROCK.
INJURED WAS DRILLING FIRST HOLE OF THE SHIFT WHN DRILL HEAD AND S TEEL BECAME PLUGGED WITH DUST INJURED TRIED SEVERAL DIFFERENT WAYS OF CLEARING MACHINE INJURED DROPPED DRILL HEAD DOWN AND PLA CED LEFT HAND ON TOP OF HEAD TO CHECK THE SUCTION WHIEL LEAVING DRILL STEEL STUCK IN ROOF INJURED ACCIDENTALLY ENGAGED DRILL HEAD LEVER IN WRONG DIRECTION SMASHING LEFT HAND BETWEEN DRILL STE
MINER HELPER AT TIME OF ACCIDNET CARRYING CABLE SAFETY GLASSES SLIPPED OFF END HIT HIM IN THE EYE CAUSING THE EYE TO INFECT
WHILE GOING THROUGH MANDOOR INJURED STOOD UP STRIKING HEAD AGAINST ROOF, WHILE DRIVING GOLFCART INTO MINE INJURED REACHED FOR HIS DINNER BUCKET AND DIDNT OBSERVED LOW ROOF APPROACHING WHICH STRUCK HEAD AGAIN
WHILE WORKING INJURED STRUCK HEAD ON CORNER OF ROOF AND RIB
AFTERNOON SHIFT OUTSIDE MAN CLEANED OUT THE RED BUILDING SWEEPING GARBAGE OUT IN FRONT AND LEAVING IT LAYING, I.NAME CAME DOWN UNLOCKED THE BUILDING STEP BACK OUT CAUGHT FOOT IN PIECE OF WIRE THROWING HIM FACE DOWN ON BLACK TOP HITTING FACE SHOULDER AND KNEE ON THE BLACK TOP CUTTING LIP AND CHEEK CUTS ON THE KNEE. WHEN FALLING BROKE MY GLASSES BRUISE SHOULDER CUT MY KNEE AND SPRAI
BAD TOP IN BLEEDER ENTRY ALSO CONTRUBUTING FACTOR MIGHT BE THE GOB LINE AND HAVING BOTTOMS.
WHILE BACK UP BOLTING WITH DDO-13 ROOF BOLTER A PIECE OF ROOF (1\X6"X1") BECAME DISLODGED. IT FELL STRIKING INJURED ON MIDDLE FINGER AS HE PUT DRILL STEEL TO ROOF. INJURED SUFFERED CUT TO INDE X FINGER.
AFTER FINISHING THE FIRST LIT OFF THE FIRST FENDER OF THE BLOCK, THE ROOF SUDDENLY AND WITHOUT WARNING FELL. THE MINER WAS SHUT DOWN WAITING ON A SHUTTLE CAR AT THE TIME. THE MINER WAS COVERED WITH 2\ TO 4\ OF MATERIAL ROM THE CANOPY TO THE CUTTER BOOM HINGE POINT AND FROM THE CUTTER BOOM HINGE POINT FORWARD WAS OF UNDETERMINED HEIGHT. THE FALL OCCURRED IN #2 BLOCK INBY #12 CROSSCU
INJURED WAS CROSSING #2 BELT CROSS OVER AT #2 DRIVE AREA. WHILE GETTING OFFCROSS OVER INJURED SLIPPED FALLING ON HIS LEFT KNEE CAUSING HIM TO JAM OR SHOCK LOAD HIS UPPER BODY, INJURED RECEIVED A MUSCLE PULL OR SIMILAR INJURY TO RIB CAGE AREA ON LEFT SIDE OF BODY.
FALL OF ROOF 4 BELT 5 ENTRY 2 CROSSCUT FALL AREA 75\ LONG 18\ WIDE 8\ HIGH.
CLIMBING OVER IDLE CONVEYOR BELT TO ROCK DUST SLIPPED AND TURNED HIS ANKLE SPRAINED ANKLE
1984 · 7 incidentes
ROOF FALL
MUD VEIN IN ROOF 1FT ABOVE 4 FT ANCHOR POINT
CLAY VEIN IN ROOF CRIBS IN #7 X CUT
SLIP IN ROOF CRIBS WERE SET IN AREA THAT FELL
THE CONDITIONS CONTRIBUTING TO THE FALL WAS UNCONSOLIDATED ROOF DUE TO APPROACHING PITTSBURGH GOB LINE
WHILE HOOKING UP BATTERY AT STATION INJ CAUGHT HAND BETWEEN BATTERY AND CHANGING ARM.
WHILE WALKING UP THE #3 BELT LINE HEAD JAMMED INTO LOW TIMBER KNOCKING INJURIED DOWN TO GROUND JAMMING HIS SPINE.
1983 · 6 incidentes
UNINTENTIONAL ROOF FALL
UNINTENTIONAL ROOF FALL
UNINTENTIONAL ROOF FALL
ACCIDENT OCCURRED IN #5 ENTRY APPROX 20 FT INBY #18 BLOCK OF COAL BOTTOM WAS DRY ROOF WAS CUT UNEVEN AND HAD HEADER BOARD ON BOLT INJ WAS WALKING UP #5 ENTRY TO #4 ENTRY WHEN HE STRUCK HIS HEA ON HEADER BOARD CAUSING SEVERE PAIN IN UPPER AND LOWER BACK INJURED FELL TO THE GROUND
WET TRAMWAY AS A RESULT OF DUST CONTROL INJURED SLIPPED ONWET BOTTOM RESULT WAS LOWER BACK STRAIN
ROOF FELL OUT IN SLIP AREA DISLODGING STANDARD BOLT PATTERN LONGER BOLTS IN AREA ARE HOLDING