Mining Incidents
Muerte · Registro MSHA n.º 220180940025

Belt Foreman

28 de marzo de 2018 a las 2:15 AM
PANTHER MINE · Underground · Coal
Harlan Condado, KY
Clasificación TRANSPORTE MOTORIZADO
Tipo Atrapado en, bajo o entre objetos en movimiento o engranados
Narrativa del investigador
The belt Foreman & 1 other employee made a belt splice on #7 mainline belt. Belt came on & foreman was dragged approx. 6-7 crosscuts before the belt stopped by a person making belt checks.

Texto original en inglés de la MSHA

Investigación final de la MSHA
On Wednesday, March 28, 2018, at approximately 2:15 a.m., Hubert Grubbs Jr., a 29-year-old Belt Foreman with 8 years of mining experience, was fatally injured when a conveyor belt on which he was working started unexpectedly. Grubbs became entangled in the conveyor belt clamp ratchet chain and was fatally injured when the conveyor belt started. At the time of the accident, Grubbs and a coworker were splicing the conveyor belt. The accident occurred because the operator allowed employees to engage in repair and maintenance work on a conveyor belt without implementing proper lock-out and tag-out procedures to ensure the electrical power was off. The conveyor belt started because a mine examiner improperly repaired a remote cable and belt switch wires, which he had damaged during his examination. The mine examiner had not been trained to repair this electrical circuit.
Causas fundamentales
  1. The mine operator performed repair and maintenance work on a conveyor belt, and did not properly lock and tag-out to ensure the electrical power was off while the work was being performed. The operator was splicing the No. 7 conveyor belt using only the belt switch to stop the conveyor belt. The mine operator did not have appropriate lock and tag-out policies and procedures.

    Acción correctiva: The mine operator submitted a written action plan, which was reviewed and acknowledged by MSHA. On April 4, 2018, the operator adopted the action plan as company policy and put it in the training plan. The policy contains the following provisions:

  2. The operator performed an improper repair of the remote cable and belt switch wires, which had been damaged during the on-shift examination. The repair caused the belt to start. The mine examiner had not been trained to repair the electrical circuit.

    Acción correctiva: The electrical circuit was repaired by a miner who was qualified to perform this repair. The mine operator retrained all miners that repairs and maintenance on any electrical circuit must be performed by a qualified electrician.

Hallazgos del informe final de investigación de la MSHA, que sustituye la narrativa preliminar anterior.

Detalles del registro
Actividad al momento del incidente
Conveyor Belt
Subunidad / ubicación
UNDERGROUND
Ubicación subterránea
INTERSECTION
Método de minería
Continuous Mining
Tipo de accidente
Atrapado en, bajo o entre objetos en movimiento o engranados
Fuente de la lesión
BELT CONVEYORS
Naturaleza de la lesión
MULTIPLE INJURIES
Parte del cuerpo afectada
TRUNK, MULTIPLE PARTS
Experiencia minera total
8 years
Experiencia en esta mina
1 year
Experiencia en este puesto
3 years
Grado de la lesión
FATALITY
Verificar en MSHA

Cada registro de esta página refleja lo que publica la MSHA en su programa de Datos Abiertos del Gobierno, actualizado semanalmente. La MSHA no publica URLs por accidente (los datos de Accidentes se distribuyen en un único archivo masivo), así que esta es la forma de recuperar la fuente del registro específico a continuación:

Fuente: Administración de Seguridad y Salud Minera de EE. UU. (MSHA) · Documento 220180940025 · ID de mina 1518198 Vista de capacitación →