UNINTENTIONAL ROOF FALL OCCURED AT THE 7TH CROSSCUT OUTBY THE 002 SECTION. THE FALL FELL ABOVE THE ANCHOR. AREA OF THE FALLW AS 20'X70'X5' THICK. FROM THE #3 BELT ENTRY AND THROUGH THE CROS S CUT AND ACROSS THE #4 RETURN AIR COURSE.
Mason No 7 Coal
Seguir esta mina
Avísenme cuando se presente un nuevo incidente de la MSHA en Mason No 7.
- Muertes
- 0
- Incidentes totales
- 4
- Años en registro
- 1993
- Último incidente
- Jun 1993
Incidentes reportables
4 en archivo1993 · 4 incidentes
EE WAS RUNNING A WILCOX J-6 ROOF BOLTING MACHINE W/ATRS BOLTING IN SEQUENCE FROM LEFT TO RIGHT; BOLTS ARE NUMBERED 1-4, WHEN PREPARING TO INSTALL BOLT #4 IN SEQUENCE, A PIECE OF DRAW ROCK FELL BETWEEN BOLT #3 AND THE RIB WHERE BOLT #4 WOULD BE INSTALLED, THE ENTRY WIDTH IS 20'.
INJURED WAS WORKING AT THE FACE OF TH EMINE AS MIENR HELPER AND WAS IN THE PROCESS OF HANGING A VENTILATION CURTAIN. E HADN'T NOTICED A LOOSE PIECE OF ROCK BETWEEN THE RIB AND THE FIRST ROW O F ROOF BOLTS, WHIHC FELL ONTO HIS BACK AS HE WAS WIRING THE CURTAIN TO A ROOF PLATE.
STRAINED HIMSELF BUY LIFTING AN UNKNOWN OBJECT. THIS REPORT REPLACEDS THE PREVIOUS ONE FOR THE SAME EE INCORRECT MSHA ID WAS REPORTED.