UNINTENTIONAL ROOF FALL. FALL MEASURED 20' LONG X 18' WIDE X 40' HIGH. AREA MINED 2/22/06. NO INJURIES OR PROPERTY DAMAGE. ROOF PREVIOUSLY SUPPORTED WITH 6' TORQUE TENSION AND 6' DOUBLE LOCK BOLTS. ONLY ENTRANCE WAS DANGERED OFF AND BROW SUPPORTED WITH 3 CRIBS. FALL MOST LIKELY WILL NOT BE SUPPORTED OR CLEANED.
Stony River Mine Coal
Seguir esta mina
Avísenme cuando se presente un nuevo incidente de la MSHA en Stony River Mine.
- Muertes
- 0
- Incidentes totales
- 5
- Años en registro
- 2001–2006
- Último incidente
- Feb 2006
| Trimestre | Horas trabajadas | Citaciones | S&S | Por 1M hrs |
|---|---|---|---|---|
| 2007 Q1 | 0 | 0 | 0 | |
| 2006 Q4 | 0 | 0 | 0 | |
| 2006 Q3 | 1,140 | 0 | 0 | 0.0 |
| 2006 Q2 | 2,949 | 0 | 0 | 0.0 |
| 2006 Q1 | 1,440 | 5 | 2 | 3472.2 |
| 2005 Q4 | 13,153 | 11 | 2 | 836.3 |
| 2005 Q3 | 744 | 10 | 3 | 13440.9 |
| 2005 Q2 | 0 | 2 | 1 |
Incidentes reportables
5 en archivo2006 · 1 incidente
2005 · 2 incidentes
Employee was in a seated position operating a radio remote controlled continuous miner when a small piece of rock fell from the roof & rib and struck him on the back of his shoulder.
Employee was roof bolting #5 Entry. He was on the "off side" of the roof bolter in a squat position with the left knee on the mine floor and the right leg posed in a 90" position. While beginning to drill the first hole a piece of rock being drilled fell from the roof, broke against the canopy, and struck the right knee.
2001 · 2 incidentes
INJURED WAS STRAIGHTENING A BENT ROOF BOLT WHEN THE ROOF BOLT SPUN AROUND STRIKING HIM ON LEFT WRIST CAUSING A FRACTURE.
ROOF FALL FROM LAST OPEN XCUT BETWEEN #5 & #6 TO LAST XCUT BETWEEN #8 TO #9 FALL 240' LONG, 8' HIGH.