An unplanned roof fall occurred on the 002-0 section, two breaks inby spad # 73724 starting in the #6 face into the #6 to #7 cross-cut. Dimension on the fall was 40' in length, 5' to 7' in width and 8' in height.
Cove Mountain Deep Mine Coal
Seguir esta mina
Avísenme cuando se presente un nuevo incidente de la MSHA en Cove Mountain Deep Mine.
- Muertes
- 0
- Incidentes totales
- 3
- Años en registro
- 2012–2014
- Último incidente
- Jul 2014
| Trimestre | Horas trabajadas | Citaciones | S&S | Por 1M hrs |
|---|---|---|---|---|
| 2015 Q1 | 0 | 0 | 0 | |
| 2014 Q4 | 0 | 0 | 0 | |
| 2014 Q3 | 2,171 | 5 | 0 | 2303.1 |
| 2014 Q2 | 21,255 | 7 | 2 | 329.3 |
| 2014 Q1 | 2,557 | 9 | 3 | 3519.7 |
| 2013 Q4 | 25,043 | 13 | 4 | 519.1 |
| 2013 Q3 | 29,455 | 6 | 0 | 203.7 |
| 2013 Q2 | 0 | 10 | 1 |
Incidentes reportables
3 en archivo2014 · 2 incidentes
An unseen roof condition above test hole height 150 feet inby spad number 73124 in entry number 5. The fall was 22 feet in length 19 feet wide and 8 feet high.
2012 · 1 incidente
EE was cutting trees for powerline. He had been cutting trees all day. He cut one small tree not foreseeing pressure from another tree pushing on the tree he was cutting. The saw kicked back chain brake was working correctly but apparently the angle he was cutting at prevented his arm from hitting the brake.