no persons or equipment involved: intersection-4-way. track hdb. #4 block from portal. had post and cribs installed. h20 dripping 1 yr. fall dim. 12' wide. 25-28' long 12'-15' high
En todo el registro
- Incidentes totales
- 740,335
- De los cuales mortales
- 3,118
- Años en el registro
- 1983–2026
- Clasificaciones
- 20
Notifícame sobre esta búsqueda
Envíame un correo cuando un nuevo incidente coincida con estos filtros. Un correo de confirmación; cancela la suscripción cuando quieras.
38 registros en total
Mostrando los 38NO PERSONS OR EQUIPMENT INVOLVED. WATER OUT OF TOP 2 DAYS AFTER MINING. INSTALLED CRIBS ON EACH SIDE OF INTERSECTION FOR SUPPORT. FALL DIMENSIONS: 15'WIDE, 20'LONG & 8-12'HIGH.
NO INJURIES OR ACCIDENTS, NO PERSONS INVOLVED, NO EQUIPMENT INVOLVED. AREA SUPPORTED WITH CRIBS & POST TRACK WAY NARROWED TO 8'-10' BEFORE FALL. FALL DIM. 12-15'LONG, 6-7'HIGH.
FALL OCCURRED ON TRACK HDG #28 BLOCK. NO PERSONSOR EQUIPMENT INVOLVED. TRIED TO SAVE AREA BUT TOO DANGEROUS. REMOVED CRIBS AND FALL OCCURRED SLOWLY. CLEAN, USED STEEL BEAM, CRIBS, 3" PLANKING AND MADE CANOPY. CREW COMPLETED JOB SAME DAY.
NO PERSONS OR EQUIPMENT INVOLVED. NO INJURIES OR ACCIDENTS. DIM 14' WIDE X 20' LONG X 6-9' HIGH. AREA SUPPORTED WITH 6' RESIN BOLTS & CENTER CRIBBED. USED CRIBS & POST TO ESTABLISH WALKWAY. VE NTILATION CONTROLS WERE NOT INTERRUPTED.
NO PERSON'S OR EQUIPMENT INVOLVED, NO INJURIES OR ACCIDENT, AREA 15' WIDE BY 25' LONG BY 6-8' HIGH. AREA BOLTED WITH 6' RESIN BOLTS. SUPPORTED AND IMMEDIATE AREA DANGERED OFF.
NO PERSONS INVOLVED, NO EQUIPMENT INVOLVED NO INJURIES OR ACCIDENTS ROOF FALL INTERSECTION 15' WX25'-30' L 15'HIGH. AREA HAD HEAD COAL 1-8" & WAS BOLTED WITH 3/4" X72"RESIN BOLTS
NO PEOPLE INVOLVED. NO ACCIDENTS OR INJURIES - ROOF FALL OCCURRED IN 4-WAY INTERSECTION - EXCESSIVE HUMIDITY IN MINES. 7'-8' HIGH, 12' X 20' LONG. CONSTRUCTED WOODEN CANOPY AND CRIBS TO SUP PORT AREA.
ROOF FALL, NO PERSONS INVOLVED NO ACCIDENT OR INJURIES. OCCURRED IN 4-WAY INTERSECTION AT CLAY VEIN AREA. PREVIOUSLY POST AND CRIBS. 6-7' HIGH. 10' WIDE X 30' LONG. CONSTRUCTED WOOD CANOPY, CR IBS, BARS, POST TO SECURE AREA.
INTERSECTION LOCATED AT #9 BLOCK ON TRACK HAULAGE. AREA HAD CLAY VEIN THRU HAG. 3'-4' THICK. HAD POST SET AND BOLTED WITH RESIN. "NO ONE INVOLVED OR INJURED"
3-WAY INTERSECTION. CLAY VEING RUNNING THRU 1 CORNER. HAD CRIB CONSTRUCTED IN MIDDLE OF INTERSECTION ALOGN WITH SEVERAL POST AT VARIOUS PTS. LOCATION 1-BLK IN-BY OUTSIDE PORTAL. INTAKE ENTR Y #4 HDG.
3-WAY INTERSECTION - CLAY VEIN THRU CENTER. HAD 10 - 12 POST SET. BLOCK #59 RETURN HD - DID NOT AFFECT AIR FLOW OR CREATE ANY RESTRICTIONS.
ROOF FALL INTERSECTION 6' RESIN BOLTS. BOLTS FULLY GROUTED SLIP IN COAL SEAM AND ROCK. COVER AREA. LESS THEN NORMAL CROSSING HOLLOW.
FALL IS LOCATED 2 BLOCKS INBY SECTION #141 IN #5 BELT ENTRY AREA WAS BOLTED WITH 6'RESIN BOLTS.FALL IS APPROXIMATELY 15'WX20'LX7'HIGH.
FALL IS LOCATED 1 BLOCK LEFT OF STATION #204 IN #1 ENTRY.AREA WAS BOLTED WITH 6'AND 9' RESIN BOLTS.FALL IS APPROXIMATELY 10'X12'X61/2'H.
FALL LOCATED 2 BLOCKS; INBY STATION #202 IN #3 ENTRY. AREA WAS BOLTED WITH 6' RESIN BOLTS AND TIMBERED. FALL IS APPROX. 18'L X 15'W X 15'H.
FALL LOCATED AT STATION #141 1 BLOCK INBY #5 TAILPICE.FALL IS APPROX 16'LX16'WX81/2'H.AREA WAS REBOOLTED WITH 2"X4"SCREEN AND 6" BOLTS.
FALL IS LOCATED 1BLOCK INBY STATION #200 IN #4 ENTRY FALL IS APPROX 20 FT X 14 FT X 8 FT AREA WAS BOLTED WITH 6 FT RESIN TIMBERED AND DANGERED OFF
FALL IS LOCATED 1 BLOCK INBY STATION #204 IN #1 ENTRY FALL IS APPROX 20 FT L X 14 FT W X 7 FT HIGH AREA WAS BOLTED WITH 6 FT RESIN TIMERED AND DANGERED OFF
THE INJURED WAS STANDING IN INTERSECTION BESIDE HAUL ROAD WHEN SHUTTLE CAR PASSED BY AND BUMPER CAUGHT 2" PLASTIC WATER LINE AND PULLED IT CATCHING HIM ON THE LEG.
LOCATED 1 BLOCK INBY STQATION 203 IN 2 ENTRY APPROX 20' W X 20' H X 8' H. AREA BOLTED WITH 6' RESIN TIMBERED AND DANGERED OFF.
FALL IS LOCATED 20' INBY STATION 194 IN 5 ENTRY. APPPROX 60' X 10' W X 6'. AREA BOLTED WITH 6' RESIN BOLTS WA> TIMBERED AND DANGERED OFF ON BOTH ENDS.
FALL LOCATED AT STATION #67 #3 BELT 2ND #4 BELT DRIVE FALL IS APPROX 20'LX25'WX6 1/2"H. AREA WAS BOLTED WITH 6'-8'& 10' RESIN BOLTS & CRIBS.
FALL LOCATED 2 BLOCKS INBY STATION #199 #5 ENTRY FALL IS APPROX 15' LONGX14' WIDEX6 1/2' HIGH WAS BOLTED WITH 6' RESIN BOLTS. TIMBERED & DANGERED OFF.
FALL LOCATED 40' INBY STATION #67.FALL IS 16' WIDE X20' LONG X12' HIGH.
FALL IS LOCATED 20' INBY STATION #67.FALL IS 14' WIDE X40H LONG X12'H.AREA WAS BOLTED WITH 5' RESIN BOLTS.HAD 10' RESIN BOLTS SPOTTED IN AREA.ALSO HAD STEEL RAIL AND POST SET.
FALL IS LOCATED IN #1 ENTRY 40' INBY SPAD #121.APPR 100' L X14' WIDE X 8' HIGH.WAS BOLTED WITH 6' RSIN AND 5"X7" CROSSBAR.
FELL 1 BLOCK INBY STATION #159. FALL IS 5'-6' HIGH, 14' WIDE AND 16' LONG. WAS BOLTED WITH 5'-3/4" BOLTS. TIMBERED OFF.
CREW WAS INSTALLING POST & 5FTX(7FT CROSSBARS TO HELP SUPPORT ROOF OF BELT ENTRY
FELL OUT AROUND BOLTS. TIMBERED OFF AROUND THIS AREA. FELL ABOVE ANCHORAGE OVER WEED END.
ROOF FALL LOCATED 2 BLOCKS INBY SPAD #28. FALL IS APPROX 15' W X 40' LONG X 12' HIGHWAS BOLTED WITH 6' RESIN BOLTS.
THE INJURED WAS TAKING SCOOP OFF CHARGE AND TWISTED HIS BACK AND HIS BACK WENT OUT.
FALL OCCURRED 1 BLOCK INBY SPADE #63 IN INSOLATED HEADING FALL W AS FOUND BY I.NAME DURING SHIFT 021588 SMALL AMOUNT HADFELL PLACE WAS POSTED & DANGERED OFF FELL ABOVE ROOF SUPPORTS ON 022488
HAD ROOF FALL ON 022688 FALL IS LOCATED OPP.500FT OUTBY FACE IN #1 HEADING FALL WAS FOUND ON 3RD SHIFT FALL IS APP.15FTX15FT-6FTTO8FT HIGH FALL FELL BY CLAY VEIN
THE ACCIDENT OC7URRED IN X-CUT LEFT OUT OF #2 ENTRY. WHILE TRAMMING BOLTER TOWARD FACE THE MACHINE KICKED SIDEWAYS PINNING OPERATOR AGAINST THE RIB THE OPERATOR THEN TRAMMED THE MACHINE AWAY F ROM HIM AND FEL5 TO THE GROUND
001 SECTION ROO0 FALL #1 ENTRY 4 BLOCK ENTRY PITTMOUH
001 SECTION R2OF FALL 1 BLOCK OUTBY FACE.
001 SECTION- RO2F FALL #2 BELT ENTRY, 20' OUTBY FACE.