A ROOF FALL WAS DISCOVERED IN THE 2 NORTH #4 MAINS, CROSSCUT 15, #2 ENTRY-INTERSECTION. THE FALL MEASURES APPROX. 25'LONG X 18'WIDE X 7'HIGH. THIS AREA IS SUPPORTED WITH 5'FULLY GROUTED RESIN BOLTS.
Five Star Mining IncMining Incidents in 2005
All MSHA-reportable accidents at Five Star Mining Inc operations in 2005. Fatalities appear first.
- Fatalities in 2005
- 0
- Total incidents
- 22
- Year
- 2005
Top incident classifications
- 01FALL OF ROOF OR BACK20 incidents
- 02SLIP OR FALL OF PERSON2 incidents
All incidents in 2005
A ROOF FALL OCCURRED IN THE MAIN SOUTH #5 PANEL, #7 ENTRY, CROSSCUT 52 TO 53. THE FALL MEASURES APPROXIMATELY 60 FEET LONG, 20 FEET WIDE, AND 5 FEET HIGH. THE AREA IS SUPPORTED WITH 4 FOOT FULLY GROUTED ROOF BOLTS.
A roof fall occurred in the 2 main north #3 crosscut 42 #6 entry intersection. The fall measures approx. 25' long, 18' wide & 12' high. The area is supported with 5' fully grouted resin bolts, 12' cable bolts and 6x6 timbers.
A ROOF FALL WAS DISCOVERED IN THE 1 SOUTH #5 PANEL, #2 ENTRY, 28 CROSSCUT - INTERSECTION. THE FALL MEASURES APPROXIMATELY 30 FEET LONG, 20 FEET WIDE, AND 10 FEET HIGH. THE AREA IS SUPPORTED WITH 4 FOOT FULLY GROUTED RESIN BOLTS, 10 FOOT POINT ANCHOR BOLTS AND 6 X 6 TIMBERS.
A roof fall occurred in the 1 South #5 Panel, 22 crosscut, #5 entry intersection. The fall measures approx. 20' long, 5' wide and 4' high. The area is supported with 4' fully grouted resin bolts.
A roof fall occurred in the 1 south #5 panel, corsscut 19, #5 entry intersection. The fall measures approx. 20 ft long, 18 ft wide, and 8 ft high. The area was supported with 4 foot fully grouted resin bolts.
A ROOF FALL OCCURRED IN THE 2NORTH #3 MAINS, 20 CROSSCUT, #4 ENTRY. THE FALL MEASURES APPROXIMATELY 90 FEET LONG, 18 FEET WIDE, AND 12 FEET HIGH. THE AREA IS SUPPORTED WITH 5 FOOT FULLY GROUTED RESIN BOLTS, 12 FOOT CABLE BOLTS, AND 6X6 TIMBERS.
A roof fall occurred in the 2 west #5, 107 crosscut #5 entry intersection. The fall measures approximately 30' long, 18' wide and 10' high. The area is supported with 5' fully grouted bolts, 10' point anchor bolts and 6x6 timbers.
A ROOF FALL OCCURRED ON THE MMU-003-0 SECTION. THE FALL IS AT CROSSCUT 30, BETWEEN ENTRIES 5 AND 6. THE FALL MEASURES APPROX. 30' LONG X 19' WIDE X 8' HIGH.
A roof fall occured in the main south #5 crosscut 4, entry 4 intersection. The fall measures approx 25 ft long, 20 ft wide, and 7 ft high. The area is supported with 4 foot fully grouted resin bolts.
A roof fall occured int he 2 north #3, 13 crosscut, #4 entry-intersection. The fall measures approx. 18' wide, 30' long, and 10' high. the area is supported with 5' fully grouted resin bolts, 6x6 timbers, and cable bolts.
A ROOF FALL OCCURRED IN THE 2 WEST #3 AT 6 CROSSCUT #6 ENTRY INTERSECTION. THE FALL MEASURES APPROX 25' LONG, 18' WIDE AND 10' HIGH. THE AREA IS SUPPORTED WITH 5 FOOT FULLY GROUTED RESIN BOLTS AND 12' CABLE BOLTS
A ROOF FALL OCCURRED IN THE 2 NORTH #2 BELT ENTRY AT 107 X-CUT INTERSECTION. THE FALL MEASURES APPROXIMATELY 30 FEET LONG, 19 FEET WIDE, AND 12 FEET HIGH. THE AREA IS SUPPORTED WITH 5 FOOT FULLY GROUTED RESIN BOLTS AND TIMBERS.
(2ND OF 2 ROOF FALLS THIS DATE.) A ROOF FALL OCCURRED AT 2 MAIN WEST #4 BELT LINE AT 62 CROSSCUT. THERE WAS A COAL RIDER IN ROOF THAT GAVE WAY. FALL WAS 25' X 25' X 10'. THE AREA IS SUPPORTED WITH 5' FULLY GROUTED RESIN BOLTS WITH TIMBER SET IN WALKWAY.
A roof fall occurred in the 1 west #3 panel at 28 crosscut, #4 entry intersection. the fall measures approx. 45 feet long, 19 feet wide, and 12 feet high. the area is supported with 5 foot fully grouted resin bolts and 10 foot point anchor bolts.
A ROOF FALL WAS DISCOVERED IN THE 2 NORTH #3 AT 9 CROSSCUT, #2 ENTRY INTERSECTION. THE FALL MEASURES APPROX 30' LONG, 18' WIDE AND 12' HIGH. THE AREA IS SUPPORTED WITH 5' FULLY GROUTED RESIN BOLTS
A ROOF FALL WAS DISCOVERED IN THE 2 MAIN WEST #3, 30 CROSSCUT, #4 ENTRY INTERSECTION. THE FALL MEASURES APPROXIMATELY 40 FEET LONG, 18 FEET WIDE, AND 8 FEET HIGH. THE AREA IS SUPPORTED WITH 5 FOOT FULLY GROUTED RESIN BOLTS.
A ROOF FALL WAS DISCOVERED ON #3 UNIT AT 10:00 PM. THE FALL IS IN #2 ENTRY, AT 49 CROSSCUT - INTERSECTION. FALL MEASURES APPROX. 30' LONG X 18' WIDE X 10' HIGH. THE AREA IS SUPPORTED WITH 5' FULLY-GROUTED RESIN BOLTS.
a roof fall was discovered int he 2 main north #4 at crosscut 19, #3 entry intersection. the fall measures approx 40 feet long, 18 feet wide, and 12 feet high. the area is supported using 5 foot fully grouted resin bolts.
EE WAS WALKING WHEN HE STARTED TO FALL AND TWISTED RIGHT KNEE. EE CONTINUED TO WORK AFTER TWISTING KNEE. MRI TEST REVEALED BONE SPUR ON RIGHT KNEE REQUIRING ARTHROSCOPIC SURGERY ON 3/7/05. ACCIDENT BECAME A LOST TIME INJURY ON 3/7/05.
EMPLOYEE WAS WALKING FROM THE FACE TO THE DINNER HOLE WHEN A PIECE OF ROCK FELL FROM BETWEEN PATTERN BOLTS. THE ROCK STRUCK EE ON THE RIGHT LEG CAUSING A LACERATION THAT REQUIRED SUTURES TO CLOSE.
EE WAS DOING REPAIRS IN #2 SUMP. HE LOST HIS FOOTING WHILE MOVING AND FELL. AREA WAS WET AT THE TIME.