A roof fall occurred in the 1 west 1 mains, 39 crosscut, #7 entry. The approximate dimensions are 8' long, 8' wide and 3' thick. The area is supported with 5' fully grouted resin bolts and 6 X 6 timbers.
Five Star Mining IncMining Incidents in 2007
All MSHA-reportable accidents at Five Star Mining Inc operations in 2007. Fatalities appear first.
- Fatalities in 2007
- 0
- Total incidents
- 92
- Year
- 2007
Top incident classifications
- 01FALL OF ROOF OR BACK83 incidents
- 02SLIP OR FALL OF PERSON3 incidents
- 03HANDLING OF MATERIALS2 incidents
- 04POWERED HAULAGE2 incidents
- 05MACHINERY1 incident
All incidents in 2007
A roof fall was discovered in the 2 north 3 mains 7 crosscut #2 entry. The fall measures approx 20' long, 18' wide and 5' thick. The area is supported with 5' fully grouted resin bolts and 10' paint anchor bolts.
A roof fall occurred in the old 2 west 3 headings, crosscut 18, #2 entry. The fall measures approx. 25 feet long, 18 feet wide, and 10 feet thick. The area is supported with 5' foot fully grouted resin bolts, and 10 foot point anchor bolts.
A roof fall occurred in the 2 West 3 Mains, #6 entry, crosscut 16. The fall measures approximately 18 feet long, 18 feet wide, and 6 feet thick. The area is supported with 5 foot fully grouted resin bolts and 10 foot point anchor bolts.
A roof fall occurred in the 2 west 1 mains crosscut 67, between #2 & #3 entries. The fall measures approx 30 feet long, 15 feet wide and 6 feet thick. The area is supported with 6 foot fully grouted resin bolts.
A roof fall was discovered in the old east panel off the 1 south main. The fall measures approximately 60' long, 18' wide and 12' thick. The fall is in entry #5, 24 to 25 xc. The area is supported with 5' resin bolts.
A roof fall was discovered in the 2 west 1 mains, 77 crosscut, between #4 and #5 entries. The fall measures approx 40' long, 18' wide and 6' thick. The area is supported with 5' fully grouted resin bolts.
A roof fall occurred in the 2 West 4 Submains, 1-2 crosscut, #6 entry. The fall measures approximately 70 feet long, 18 feet wide, and 10 feet thick. The area is supported with 5 foot fully grouted resin bolts and 10 foot point anchor bolts.
A roof fall occurred in the 2 North 1 Mains, 14 Crosscut, #4 entry. The fall measures approximately 30 feet long, 18 feet wide, and 10 feet thick. The area is supported with 5 foot fully grouted resin bolts, 6x6 timbers, and 12 foot cable bolts.
A roof fall occurred on #1 unit, #1 entry, from 15 to 16 cross cut. This section is in the 2 main west #3 mains. The fall measures approximately 70 feet long, 18 feet wide and 10 feet thick. The area is supported with 5 foot fully grouted resin bolts and 10 foot point anchor bolts.
A roof fall occurred on #1 unit, mmu-001-0, 16 crosscut, #10 entry. The fall measures approx. 15' long, 10' wide & 6' thick. The area is supported with 5' fully grouted resin bolts and 10' point anchor bolts.
A roof fall was discovered in the 2 west 1 mains, 59 crosscut, between #1 & 2 entries. The fall measures approximately 25 feet long, 18 feet wide and 10 feet thick. The area is supported with 5 foot fully grouted resin bolts.
A roof fall was discovered in the 2 North 2 Mains 107 crosscut between #1 & #2 entries. The fall measures approximately 10' long, 8' wide & 7' thick. The area is supported with 5' fully grouted resin bolts.
A roof fall was discovered in the 1 west 1 mains, 31 crosscut, between #3 & #4 entries. The fall measures approx 25' long X 18' wide X 6' thick. The area is supported with 5' fully grouted resin bolts.
A roof fall was discovered in the 1 west 1 mains, #6 entry 35 crosscut. The fall measures approximately 18 feet long, 20 feet wide, and 14 feet thick. The area is supported with 5 foot fully grouted resin bolts.
A roof fall was discovered in the 2 north #3 mains, #5 entry, between 56 & 57 corsscut. The fall measures approx. 25' long, 18' wide, and 5' thick. The area is supported with 5 foot fully grouted resin bolts.
A roof fall was discovered in the 2 West 2 Mains, # 1 Crosscut, # 4 Entry. The fall measures approximately 50 feet long, 18 feet wide and 10 feet thick. The area is supported with 5 foot fully grouted resin bolts.
A roof fall was discovered in the 2 north mains, 76 crosscut, #3 entry. The fall measures approx 18' long, 18' wide and 9' thick. The area is supported with 5' fully grouted resin bolts.
A roof fall was discovered in the 2 North 2 Mains 77 crosscut from #4 to #5 entry. Fall measures approximately 35' long, 18' wide & 10' thick. Area is supported with 5' fully grouted resin bolts.
A roof fall was discovered in the 2 North 3 Mains, 41 crosscut, #1 entry. The fall measures approximately 20' long, 20' wide and 8' thick. The area is supported with 6' point anchor bolts.
A roof fall was discovered in the 2 west 1 mains, 59 crosscut from #1 to #2 entry. Fall measures approximately 80' long, 18' wide and 10' thick. The area is supported with 5' fully grouted resin bolts.
A roof fall was discovered in the 1 west 3 panel, #4 entry, crosscut 22. The fall measures approx. 30' long, 18' wide & 8' thick. The area is supported with 5' fully grouted resin bolts.
A roof fall was discovered in the old 2 North 4 Mains, 11 crosscut, between #3 & 4 entries. This fall is in an area that seal plans have been submitted for 3 months! The fall measures approx. 15' long, 15' wide, 6' thick. The area is supported with 5' fully grouted resin bolts.
A roof fall occurred in the 1 west 3 panel (#4 unit), 40 crosscut #2 entry. The fall measures approx 10' long, 18' wide and 5' thick. The area is supported with 5' fully grouted resin bolts.
A roof fall occurred in the 1 west panel (#4 unit), crosscut 38, #0 entry. The fall measures approximately 20 feet long, 18 feet wide and 4 feet thick. The area is supported with 5 foot fully grouted resin bolts.
A roof fall was discovered in the 2 North Mains, Crosscut 9, between #3 & 4 entries. The fall is approximately 25 feet long, 17 feet wide and 5 feet thick. The area is supported with 5 foot fully grouted resin bolts.
A roof fall occurred on #4 unit, 1 west 3 panel, 39 Crosscut, #1 entry. The fall measures approximately 20 feet long, 10 feet wide, and 5 feet thick. The area is bolted with 5 foot fully grouted resin bolts.
A roof fall was discovered in the 1 West Mains, crosscut 7, #1 entry. The fall measures approximately 20 feet long, 20 feet wide and 7 feet thick. The area is supported with 5 foot fully grouted resin bolts.
A roof fall occurred in the 2 Main West #2, Crosscut #11, from #10 to #11 Entries. The fall measures approximately 65 feet long, 17 feet wide and 9 feet thick. The area is supported with 5 foot fully grouted resin bolts.
A roof fall was discovered in the 2 West Mains, 69 Crosscut, #7 Entry. The fall measures approx 20' long, 20', 20' wide and 8' thick. The area is supported with 5' fully grouted resin bolts.
A roof fall was discovered in the 1 west 3 panel, 21 crosscut, #3 entry. The fall measures approx. 20 feet long, 18 feet wide, and 10 feet thick. The area is supported with 5 foot fully grouted resin bolts.
A roof fall was discovered in the 2 West 1 Mains, 83 crosscut, #7 entry. The fall measures approximately 17 feet long, 17 feet wide, and 6 1/2 feet thick. The area is supported with 5 foot fully grouted resin bolts.
A roof fall was discovered in the 2 North 3 Mains, Crosscut 17, #2 Entry. The fall measures approx 20' long, 17' wide and 7' high. The area is supported with 5' fully grouted resin bolts.
A roof fall occurred in the 1 west 3 panel, crosscut 10, #9 entry. The fall measures approx 30' long X 17' wide X 8' thick. The area is supported with 5' fully grouted resin bolts.
A roof fall occurred in the 1 west 3 panel, 18 crosscut, #6 entry. The fall measures approx 17' long X 15' wide X 6' thick. The area is supported with 5' fully grouted resin bolts.
A roof fall was discovered in the South Submain off the 1 Main West, 16 crosscut, #7 entry. The fall measures approximately 20 feet long, 16 feet wide, and 8 feet thick. The area is supported with 5 foot fully grouted resin bolts.
The continuation of an existing fall was discovered in the 1 South #2 Panel, 38 Crosscut, from #4 to #7 entry. The fall measures approximately 100 feet long, 18 feet wide, and 8 feet thick. The area is supported with 5 foot fully grouted resin bolts.
A roof fall was discovered in the 2 North #5 abandoned Mains, 63 crosscut from #5 to #7 entries. The fall measures approximately 130 feet long, 18 feet wide, and 8 feet thick. The area is supported with 6 foot fully grouted resin bolts.
A roof fall was discovered in the abandoned 2 North 5 Mains, 25 Crosscut, #2-3 entry. The fall measured approximately 10 feet thick, 18 feet wide, and 100 feet long. The area is supported with 6 foot fully grouted resin bolts.
A roof fall was discovered in the 2 north 3 mains, 15 crosscut, #1 entry. The fall measures apprx 8' thick, 18' wide and 40' long. The area is supported with 6' fully grouted resin bolts.
A roof fall was discovered on #4 unit, Spad #18494 #8 entry, 9 crosscut. The fall measured approx 18' w x 24' l x 10' thick. The area is supported with 5' fully grouted resin bolts.
A roof fall occurred on #3 unit, 38 crosscut, #6 entry. The measures approx 18' w x 36' l x 10f thick. The area is supported with 5' fully grouted resin bolts.
A roof fall occurred in the 2 West 1 Mains, 80 crosscut, #5 entry. The fall measures approximately 18 feet wide, 30 feet long, and 10 feet thick. The area is supported with 5 foot fully grouted resin bolts.
A roof fall was discovered in the 2 West #1 Mains, crosscut 83, #2 entry. The fall measures approximately 18 feet wide, 18 feet long, 12 feet thick. The area is supported with 5 foot fully grouted resin bolts.
A roof fall was discovered in the 1 west 2 submains 32 crosscut #2 entry. The fall measures approx 50' l x 18' w x 8' thick. The area is supported with 5' fully grouted resin bolts.
A ROOF FALL WAS DISCOVERED IN THE OLD 2 NORTH 5 MAINS, AT 61 CROSSCUT, BETWEEN #3 & 4 ENTRIES. THE FALL MEASURES APPROXIMATELY 20 FEET LONG, 18 FEET WIDE, AND 5 FEET THICK. THE AREA IS SUPPORTED WITH 5 FOOT FULLY GROUTED RESIN BOLTS.
A roof fall occurred in the 2 west 2 mains, 9 crosscut, between #5 & #6 entries. The fall measure approx 18'l x 18'w x 7' thick. The area is supported with 5'fully grouted resin bolts.
A roof fall occurred in the 2 West 2 Mains, from 9-10 Crosscut in #6 Entry. The fall measures approximately 25 feet long, 18 feet wide and 10 feet thick. The fall area is supported with 5 foot fully grouted resin bolts.
A roof fall was discovered in the 2 north 6 mains, 94 crosscut, #5 entry. The fall measures approximately 30 feet long, 20 feet wide and 10 feet thick. The area is supported with 5 foot fully grouted resin bolts.
A roof fall was discovered in the 2 West 2 Mains, #2 entry, #4 crosscut. The fall measures approximately 50 feet long, 18 feet wide, and 10 feet thick. The area is supported with 5 foot fully grouted resin bolts.
A roof fall was discovered in the 2 North #5 Return air course, at # 44xc in #2 Entry. The fall measures approximately 20' long by 18' wide by Approximately 8' High. The area was supported with 5' fully grouted resin bolts.
A roof fall was discovered in the 2 South #2 Intake Air Course. The fall was located at #18 xc 2 South # 2 in # 9 Entry. The fall measures approximately 40' in length by 18' wide and approximately 6' to 8' thick. The area is supported with 5' fully grouted resin roof bolts plus 10' point anchor bolts.
A roof fall was discovered in the old 2 North 8 abandoned panel #4 entry, at crosscut 9. The fall measures approx 20' long, 18' wide and 8' thick. The area is supported with 5' fully grouted resin bolts.
A roof fall was discovered in the 2 West 2 Mains, #4 entry, crosscut 8. The fall measures approximately 25 feet long, 18 feet wide and 5 feet thick. The area is supported with 5 foot fully grouted resin bolts.
A roof fall was discovered in the 3N1 panel, #3 entry, crosscut 50. The fall measures approx 16' long X 16' wide X 8' thick. The area is supported with 5' fully grouted resin bolts.
A roof fall was discovered in the 2 North 5 Mains, 61 crosscut, #6-7 entry. The fall measures approx 65' long X 18' wide X 8' thick. The area is supported with 5' fully grouted resin bolts.
A roof fall was discovered in the 2 North 3 Mains, #2 entry, crosscut 17-18. The fall measures approximately 70' long, 18' wide and 6' thick. The area is supported with 5' fully grouted resin bolts.
A roof fall was discovered in the 1 North Mains, Crosscut 30, #8 entry. The fall measures approximately 70 feet long, 18 feet wide, and 8 feet thick. The area is supported with 5 foot fully grouted resin bolts.
A roof fall was discovered in the 2 North 5 Mains, crosscut 25, #2 entry. The fall measures approximately 30 feet long, 20 feet wide, and 6 feet thick. The area is supported with 5 foot fully grouted resin bolts.
A roof fall was discovered in the 2 North #5 Mains, 48 crosscut, between #6 & 7 entry. The fall measures app. 40 feet long, 18 feet wide, and 8-10 feet thick. The area is supported with 5 foot fully grouted resin bolts.
A roof fall occurred in the 2 west #3 mains, 85 crosscut, #5 entry. the fall measures approx. 12 feet long, 12 feet wide, and 5 feet thick. The area is supported with 5 foot fully grouted resin bolts.
A roof fall occurred in the 1 west 3 mains, 67 crosscut, #3 entry. The fall measures approx. 20 feet long, 20 feet wide, and 5 feet thick. The area is supported with 5 foot fully grouted resin bolts.
A piece of rock fell in the 2 north #5 mains, 64 crosscut, #3 entry. The rock measures, approx. 7 feet long, 4 feet wide, and 2 feet thick. The area is suported with 5 foot fully grouted resin bolts.
A roof fall was discovered in the old 2 west 2 panel, 11 crosscut, #2 entry. The fall measures approx 25' long, 18' wide and 6' high. The area is supported with 5' fully grouted resin bolts.
A roof fall occurred in the 2 North #5 Mains, 65 crosscut, #3 entry. The fall measures approximately 25 feet long, 18 feet wide, and 14 feet thick. The area is supported with 5 foot fully grouted resin bolts.
A roof fall was discovered in the 2 north #5 Mains, 51 Crosscut, #6 Entry. The fall measures approximately 35 feet long, 18 feet wide and 7 feet thick. The area is supported with 5 foot fully grouted resin bolts.
A roof fall occurred in the 1 South 4 Panel, #4 entry, 16 crosscut. The fall is approximately 35 feet long, 20 feet wide, and 7 feet thick. The area is supported with 4 foot fully grouted resin bolts.
A roof fall occurred on #2 unit, crosscut 25, between #1 & #2 entries. The fall measures 40' long, 20' wide and 7' thick. The area is supported with 5' fully grouted resin bolts.
A roof fall was discovered in the 2 North 5 Mains, 48-49 Crosscut, #7 Entry. The fall measures approximately 15 feet long, 15 feet wide and 6 feet thick. The area is supported with 6 foot fully grouted resin bolts.
A roof fall was discovered in the 2 North 2 mains at 89 crosscut in #1 entry. The fall measures approximately 30 feet long, 18 feet wide and 7 feet thick. The area is supported with 5 foot fully grouted resin bolts and 6 x 6 timbers.
A roof fall occurred in the 2 North 5 Mains @ 48 crosscut between #3 and #4 entries. The fall measures approx. 40 ft long, 18 ft wide, and 5 ft thick. The area is supported with 5 foot fully grouted resin bolts.
A roof fall was discovered in the 2 North #6 mains, 68 crosscut, from #1 to #2 entry. The fall measures approximately 70' long, 18' wide and 6' thick. The area is supported with 5' fully grouted resin bolts.
A roof fall was discovered in the 2 main west #1, 29 crosscut, #4 entry. The fall measures approximately 30' long, 20' wide, and 9' thick. The area is supported with 6 foot point anchor bolts.
A roof fall was discovered in the 2 west #1 mains, 21 crosscut, #2 entry. The fall measures approximately 20' long, 20' wide and 8' thick. The area is supported with 6' point anchor bolts.
A roof fall was discovered in the old 2 west #3 aircourse, #6 entry, at 80 crosscut. The fall measures approx 35' long, 18' wide and 7' thick. The area is supported with 5' fully grouted resin bolts.
The continuation of an existing roof fall was discovered in the 2 north #3 mains, 28 crosscut, #8 entry. The fall measures approximately 30' long, 18' wide, and 8 feet thick. The area is supported with 5 foot fully grouted resin bolts and 12 foot cable bolts.
A roof fall occurred in the 2 North #5 mains 61 crosscut from #4 to #5 entry. The fall measures approximately 65 feet long, 18 feet wide and 12 feet thick. The area is supported with 5 foot fully grouted resin bolts.
A roof fall was discovered in the 2 north #5 Mains, #2 entry, at 46 crosscut. The fall measures approximately 20 feet long, 18 feet wide and 8 feet thick. The area is supported with 5 foot fully grouted resin bolts.
A roof fall was discovered in the 2 north #6 mains, #3 entry, at 69 crosscut. The fall measure approx. 25 ft long, 18 ft wide, and 6 ft thick. the area is supported with 5 foot fully grouted resin bolts.
A roof fall was discovered in the 2 west #1 mains, at 60 xc, #6 entry. The fall measures approx. 25 feet cong, 18 ft wide and 6 ft high. The area is supported with 5 foot fully grouted resin bolts.
Employee was positioning pipe on the surface when he felt pain in left bicep area. He sustained a ruptured left bicep tendon.
EE was carrying a timber in mud on 12/7/07, when he slipped and felt pain in his left knee. EE continued to work until 12/28/07. This accident became MSHA reportabe on 12/28/07 as EE missed work as a result of knee pain, doctor recommendation.
Employee was standing on #1 unit, #3 entry at 16 crosscut when roof rock fell striking ee on left shoulder causing simple fracture of left scapula.
Employee drilled hole in roof on #1 unit in 7-Right when roof rock fell striking him on right leg. He sustained a simple non-displaced fracture in the right knee area.
Employee attempted to hook cable ropes onto tail of moving miner when tail struck employee. Employee sustained a simple fracture of the pelvis. This accident occurred on #2 unit at 27 crosscut, between #3 & 4 entries.
Employee was pulling on Rockdust hose in crosscut when he let hose go and attempted to walk out of crosscut 11 on the 2 West 1. He tripped over rock and fell dislocating right thumb. Employee missed work on 8/10/07.
EE was attempting to relieve shuttle car driver, when he was struck by shuttle car and knocked down. EE missed work on 5/10/07.
Employee was attempting to manually push a pallet at the warehouse when he felt sharp pain in left Achilles tendon area. The tendon ruptured.
Employee was servicing equipment when he stepped on rock and felt pain in right knee.
Employee was walking belt line when she tripped and fell, lacerating left knee requiring sutures.
Employee was building a stopping when a piece of roof rock fell from between pattern bolts striking his right hand. Employee sustained a simple fracture to the right thumb.