Mining Incidents
Muerte · Registro MSHA n.º 220193020002

Electrician

18 de octubre de 2019 a las 9:00 AM
Mine #1 · Underground · Coal
Floyd Condado, KY
Clasificación DESPRENDIMIENTO DE FRENTE/COSTILLA/PILAR/COSTADO/TALUD
Tipo Golpeado por objeto que rueda o se desliza
Narrativa del investigador
While employee was working on the ride a piece of rock rolled off coal rib, striking them in the back. Pinning them against the personal ride.

Texto original en inglés de la MSHA

Investigación final de la MSHA
On Friday, October 18, 2019, James R. Senters, a 60-year-old electrician with 12 years of mining experience, was working between a coal pillar and a personnel carrier when coal/rock fell from the rib and pinned him against the carrier. The coal/rock rib that fell weighed approximately 1,250 pounds and measured 79 inches long, 26 inches wide, and 8 inches thick. Lifeguard Ambulance Service transported Senters to the Pikeville Medical Center (PMC) for treatment of his injuries. He was released from the Medical Center on October 25, 2019. Senters was at home on November 4, 2019, when he complained that he was having trouble breathing and suddenly became unresponsive, slumping to the floor. He was taken by ambulance to PMC where he died later the same day. The accident occurred because the mine operator did not effectively control the coal/rock ribs on the 001 Mechanized Mining Unit (MMU).
Causas fundamentales
  1. The mine operator’s rib support practices did not control the ribs to protect miners from rib fall hazards.

    Acción correctiva: The mine operator stopped mining in the area where the accident occurred and started mining in an area where the mining height would be 6 feet or less. The mine operator also submitted a revision to the roof control plan for areas where the mining height exceeds 6.5 feet. MSHA approved this revision on November 8, 2019, which requires all areas having a mining height of 6.5 feet and above to be rib bolted. One row of rib bolts is required at a maximum spacing of 8 feet, when the mining height is 6.5 to 8 feet. Two rows of rib bolts, at a maximum spacing of 6 feet, are required when the mining height is 8 feet or more. All rib bolts are at least 4 feet long and used with pans, headers, or straps.

Hallazgos del informe final de investigación de la MSHA, que sustituye la narrativa preliminar anterior.

Detalles del registro
Actividad al momento del incidente
Machine Maintenance
Subunidad / ubicación
UNDERGROUND
Ubicación subterránea
INTERSECTION
Tipo de accidente
Golpeado por objeto que rueda o se desliza
Fuente de la lesión
CAVING ROCK,COAL,ORE,WSTE
Naturaleza de la lesión
FRACTURE,CHIP
Parte del cuerpo afectada
CHEST (RIBS/BREAST BONE/CHEST ORGNS)
Experiencia minera total
12 years
Experiencia en esta mina
12 years
Experiencia en este puesto
12 years
Grado de la lesión
FATALITY
Verificar en MSHA

Cada registro de esta página refleja lo que publica la MSHA en su programa de Datos Abiertos del Gobierno, actualizado semanalmente. La MSHA no publica URLs por accidente (los datos de Accidentes se distribuyen en un único archivo masivo), así que esta es la forma de recuperar la fuente del registro específico a continuación:

Fuente: Administración de Seguridad y Salud Minera de EE. UU. (MSHA) · Documento 220193020002 · ID de mina 1519835 Vista de capacitación →