UNINTENTIONAL ROOF FALL OCCURED INT EH #6 ENTRY, O N 1 ST WEST MAINS 1 BREAK INBY SPAD #261. FALL WAS APPROX 6'HX20'WX20'L (IN INTERSECTION). THE AREA WAS SUPPORTED WITH 5' FULLY GROUTED RES IN BOLTS WITH ADDITIONAL SUPPORT CONSISTIN GOF CRIBBS ALONG LEFT RIB. NO INJURIES OCCURRED NO EQUIPMENT WAS CUAGHT, VENTILATION WAS NOT INTERRUPTED. INTAKE ESCAPEWA WAS BLOCKED FROM TRAVEL.
Jones Fork E1-B5 Coal
Registro de la MSHA sobre Jones Fork E1-B5 (ID de mina 1517213). Muertes, incidentes no mortales agrupados por año, operador y controlador actuales, y contexto de la mina.
Seguir esta mina
Avísenme cuando se presente un nuevo incidente de la MSHA en Jones Fork E1-B5.
- Muertes
- 0
- Incidentes totales
- 18
- Años en registro
- 1993–1994
- Último incidente
- Nov 1994
Incidentes reportables
18 en archivo1994 · 11 incidentes
EE WAS IN THE PROCESS OF REMOVING LINE CURTAIN HAD PULLED ON CURTAIN ONCE IT DID NOT COME LOOSE, PULLED THE SECOND TIME CURTAIN CAME LOOSE THE TOP OF EE RIGHT HAND STRUCK A METAL STRAP, METAL STRAP CUT THUR EE GLOVE LACERATING TOP OF RIGHT HAND. THE LACERATION REQUIRED 6 SUTURES.
UNINTENTIONAL ROOF FALL IN #4 ENTRY; ON 2 SOUTH BELT; 1 BREAK INBY SPAD #697. FALL MEASURED 40' L X 35' W(IN INTERSECTION) X UNDETERMINABLE HEIGHT. NO EQUIPMENT (OTHER THAN BELT) CAUGHT, VENTI LATION NOT INTERRUPTED, & NO INJURIES OCCURRED. AREA SUPPORTED W/ 5' FULLY GROUTED RESIN BOLTS & SUPPLEMENTAL 9' POIN ANCHOR BOLTS. THIS FALL WILL NOT BE CLEANED UP.
EE WAS IN THE PROCESS OF TRANSFERRING A BUNDLE OF ROOF BOLT PLATES FROM SCOOP BUCKET TO BOLTER WHEN HE FELT PAIN IN HIS RIGHT SIDE AND LOWER BACK.
A ROOF FALL OCCURRED IN THE #7 ENTRY 50FT INBY SPAD #B42 THE R ALL MEASURED APPROX 70FT LONG X20FT WIDE X8FT HIGH THE AREA WAS SUPPORTED WITH 5FT FULLY GROUTED RESIN BOLTS WITH SUPPLEMENT SUPP ORT CONSISTING OF 12FT COMBIMATION BOLTS NO INJU RIES OCCURRED VENTILATION WAS NOT INTERRUPTED FALL WILL NOT BE CLEANED UP
A ROOF FALL OCCURRED IN THE #5 ENTRY, 1 BREAK INBY SPAD #512. THE FALL MEASURED APPROXIMATELY 70' TO 80' LONG X 20' WIDE X 5' TO 10'HIGH. THE AREA WAS SUPPORTED WITH 5' FULLY GROUTED RESIN B OLTS WITH SUPPLEMENT SUPPORT CONSISTING OF 12' COMBINATION BOLTS. NO INJURIES OCCURRED, VENTILATION WAS NOT INTERRUPTED. FALL WILL NOT BE CLEANED UP.
A ROOF FALL OCCURRED IN THE 4 ENTRY AT 11 BREAK ON 1 SOUTH BELT, 1 BREAK INBY SPAD 545. THE FALL MEASURED 5FT TO 12FT HIGHX 20 FT WIDEX 80 FT LONG. THE AREA WAS SUPPORTED W/4FT FULLY GROUTED R ESIN BOLTS AND SIX 12 FT COMBINATION BOLTS IN THE INTERSECTIONS. FALL HAS BELT LINE CAUGHT, NO OTHER EQUIPMENT CAUGHT. NO INJURIES OCCURRED. VENTILATION WAS NOT INTERRUPTED. FALL WILL BE CLEA
UNINTENTIONAL ROOF FALL ON 2 WET BELT, 2 BREAKS INBY SPAD #476. FALL MEASURED 20'X20'X5 1/2K. AREA WAS SUPPORTED W/5' RESIN BOLTS. THE BELT WAS TEMPORARILY CAUGHT. NO OTHER EQUIPMENT CAUGHT. NO INJURIES. VENTILATION NOT INTERRUPTED. THIS FALL WILL BE CLEANED UP.
AN UNINTENTIONAL ROOF FAL OCCURRE DITN EHE1-B5 MINES 3 BREAKS INBY SPAD #464 IN THE #1 ENTRY. TE FALL WAS APPROX 4'TO 7' HIGH X 18'WX120'L. THE AREA HAD BEEN SUPPORTED WITH 5' FULLY GROUTED RESIN BOLTS WITHA DDITIONAL SUPPORT IN INTERSECTIONS CONSISTING OF 8' COMBINATION BOLTS. NO INJURIES OCCURRED, VENTILATION WAS NOT INTERRUPTED, NO EQUIPMENT WAS CAUGHT. THIS FALL WILL NOT BE
EMPLOYEE WAS INT HE PROCESS OF RE-INSTALLING LINE CURTAIN IN #2 LEFT CROSSCUT WHEN TURNED TO SEE WHERE THE FRONT MOBIL BRIDGE WAS, HIS LEFT FOOT GOT CAUGHT UNDER CRAWLER TRACK. EMPLOYEE SUSTA INED CRUSHING INJURY TO TOES ON LEFT FOOT.
EE HAD PICKED UP A 50 LB BAG OF ROCK DUST OFF OF SCOOP TURNED TO GO TOWARD FACE IN 2 ENTRY WHEN HE TWISTED HIS RIGHT KNEE.
1993 · 7 incidentes
EMPLOYEE WAS WALKING IN #4 ENTRY, WHEN HE WALKED HEAD FIRST INTO AN OFFSET IN THE LEFT RIB. HE EXPERIENCD TEMPORARY PAIN IN BOTH ARMS. FIRST DAY MISSED DUE TO THIS INJURY WAS 12-17-93.
AN UNINTENTIONAL ROCK FALL OCCURRED ABOVE ANCHORAGE IN THE E1-B5 MINES IN AN INTERSECTIO OF THE #4 ENTRY AT 48 BRK ON THE WEST MAINS (1BRK INBY SPAD#272) FALL IS APPROX 20FTX20FTWX9FTH AREA HA D BEEN SUPPORTED BY 5FT RESIN BOLTS NO INJURIES OCCURRED NO EQUIPMENT WAS CAUGHT & VENTILATION WAS NOT INTERUPTED THIS FALL WILL BE CLEANED UP
AN UNINTENTIONAL ROCK FALL OCCURED ABOVE THE ANCHORAGE IN THE E2-B5 MINES ON THE WEST MAINS AT 42 BREAK (50' INBY SPAD #248). THE FALL WAS APPROX. 110' LONG 18' WIDE AND OF UNDETERMINABLE HEIG HT. THE AREA HAD BEEN SUPPORTED BY 4' RESIN BOLTS. NO INJURIES OCCURRED, VENTILATION WAS NOT INTERUPTED, AND NO EQUIPMENT WAS CAUGHT.
EMPLOYEE HAD DISMOUNTED MOBILE BRIDGE HE WAS OPERATING WALKING IN THE #3 ENTRY WHEN HE STEPP ED ON LOOSE COAL CAUSING HIS LEFT FOOT TO SLIDE CAUSING LEFT KNEE TO BE TWISTED. EMPLOYEE'S FIRST SHIFT MISSED DUE TO THIS INCIDENT WAS 7-1593.
AN UNINTENTIONAL ROOF FALL OCCURRED ABOVE ANCHORAGE IN TEH E1-B5 MINES ONT EH MAINS AT #54 BREAT (1 BREAK INBY SPAD #316). THE FALL WAS APPROX 7' HIGH, 80' LONG, 18'-19'LWIDE, THE AREA HAD B EEN SUPPORTED WITH 5' RESIN BOLTS WITH ADDITIONAL SUPPLEMENTURY CONSISTING OF 8' BOLTS. NO INJURIES OCCURRED, VENTILATION WAS NOT INTERUPTED, NO EQUIPMENT WAS CAUGHT.
EMPLOYEE WAS HELPING CHANGE STACKER BELT SCRAPER, WAS LIFTING UP ON SCRAPER SUPPORTING SCRAPPER WHILE ANOTHER EMPLOYEE WAS LOOSENING SHOCK, SCRAPER ROTATED CATCHING SIDE OF LEFT HAND. EMPLOYEE SUSTAINED LACERATION REQUIRING 4 SUTURES, (EMPLOYEWE WAS WEARING GLOVES).
EE & ANOTHER EMPLOYEE WERE PULLING CABLE (40BE) UP BY HAND IN THE $4 ENTRY IN PREPARATION FOR A POWER MOVE DURING THIS PROCESS EE EXPERIENCED SOME PAIN IN HIS LOWER BACK
The full compliance file on Jones Fork E1-B5
A dated report covering the 26-year penalty trail, line-item violation pattern, contest and docket posture, rate-normalized peer benchmark, and full fatality history. Delivered as a PDF with the underlying data as CSV.