WHILE DOING SUPPLEMENTAL WEEKLY RUN A ROOF FALL WAS DISCOVERED IN THE 4 S.E. RETURN ENTRY. THIS AREA HAD BEEN EXAMINED ON MONDAY AND A SUPPLEMENTAL EXAM. WAS CONDUCTED FRIDAY WHICH REVEALED TH E ROOF FALL. THIS FALL STARTED 40'OUTBY SS 012 AND EXTENDED 70'L, 18'W AND 8' H.
Diamond T B Mine Coal
Seguir esta mina
Avísenme cuando se presente un nuevo incidente de la MSHA en Diamond T B Mine.
- Muertes
- 0
- Incidentes totales
- 147
- Años en registro
- 1992–1998
- Último incidente
- May 1998
Incidentes reportables
147 en archivo1998 · 8 incidentes
AN AREA OF SUBNORMA 1 ROOF FELL IN THE 3 ENTRY S.E. MAINS STARTING 40' INBY SS. THE FALL MEASURED APPROX. 40' LONG BY 8' HIGH X 18' WIDE. THIS AREA HAD BEEN SUPPORTED WITH 6' BOLTS RESIN AND T -5 CHANNELS.
AN AREA OF SUBNORMAL ROOF FELL FROM XCUT 3 TO 4 ENTRY TO MOUTH OF #3 ENTRY, 2 SOUT. FALL MEASURED APPROX. 18' WIDE BY 50' LONG BY 0-12' HIGH. THE AREA HAD BEEN BOLTED WITH 6" RESIN BOLTS AND T -5 CHANNELS.
A ROOF FALL OCCURRED IN AIR COURSE NE. #5 ENTRY INBY 3 SOUTH FROM SS#1190 TO SS#1224. THE FALL FOUND ON WEEKLY EXAM. MEASURED APPROX. 8' HIGH X 18' WIDE X 80' LONG.
AN INTERSECTION IN THE NE MAINS #1 ENTRY FELL AT SS#534 XCUT 1-2. THE FALL MEASURED APPROX. 18' X 20' X 6-8' HIGH. THE AREA HAD BEEN BOLTED WITH 6' RESIN BOLTS AND T-3 CHANNELS.
A ROOF FALL IN THE INTERSECTION AT THE FACE OF #6 ROOM OFF THE 1 LEFT ENTRIES OCCURRED. THE FALL MEASURED APPROX. 35'L, 18'W, 6' TO 8'H. THE AREA HAD BEEN SUPPORTED WITH 6' RESIN RODS & STRAPS .
A ROOF FALL OCCURED IN THE 1LT PILLAR SECTION IN X CUT 1-2 EXTENDING TO X CUT 2-3 HALFWAY. THE X CUT 1-2 IS LOCATED JUST OUTBY SS#1918 IN #1 ENTRY THE AREA OF THE FALL MEASURED APPROX. 70' LON G X 18' WIDE X 6 1/2' HIGH. THE AREA HAD BEEN BOLTED WITH 6' RESIN BOLTS.
AN AREA OF SUBNORMAL ROOF ADJACENT TO A PREVIOUS FALL JUST OUTBY THE PILLAR LINE, IN THE 1 LEFT 005 SECTION CAVED. THE FALL MEASURED APPROX. 30'X20'X6' HIGH AND INCLUDED THE INTERSECTION IN #4 ENTRY EXTENDING INTO X-CUT 4-5. FALL IS CRIBBEDOFF.
1997 · 31 incidentes
WHLE DOING WEEKLY EXAM. MINE EXAMINER FOUND FALL IN AN UNUSED X-CUT BETWEEN THE #2 AND #3 ENTRIES OF OLD N.E. MAINS FALL MEASURED APPROX 20'LX18'WX6-8'H. AREA HAD BEEN BOLTED WITH 6-8' RESIN B OLTS AND STRAPS.
AN INTERSECTION IN THE 2 PANEL OFF 1 LEFT BUTT AT 55# 2182 FELL 6 TO 8' HIGH X 18' WIDE X 18' LONG THIS IS NOT ON SECTION ADDITIONAL SUPPORTS WILL BE SET AND FALL DANGERED OFF.
AN INTERSECTION IN THE #4 ENTRY OF 1 LEFT PANEL OCCURRED MEASURING APPROX. 18' WIDE X 24' LONG X 8' HIGH. THE AREA HAD BEEN BOLTED WITH 6' RESIN BOLTS AND STRAPS. MINIMUM ROOF CONTROL IS 4' RE SIN ON 4' CENTERS.
A ROOF FALL OCCURED IN THE A BUTT #3 ENTRY SUMP AREA MEASURING APPROX 30'LX18'WX APPROX 5'HIGH. THIS AREA WAS INITIALY SUPPORTED WITH 4'RESIN BOLTS AND STRAPS. A SPARE 6" SUBMERSIBLE PUMP WAS COVERD BY FALL.
AN ARCH OF SUBNORMAL ROOF FELL IN THE INTERSECTION OF THE 1 LEFT BUTT #1 ENTRY AND 2ND PANEL #2 ENTRY THE FALL MEASURED APPROX 18'WX18'LXAPPROX 6'H. THE RIDER SEAM WAS OBSERVED AT THE TOP OF T HE FALL. THIS AREA IS EXAMINED WEEKLY.
AFTER FINISHING PUSH OUT IN 49 STUMP ROOF STARTED OVER RIDING AND SETTLING IN 3 & 4 ENTRY PULLING ROOF BOLTS. AREA WAS APPROX 6-8' HIGH X 18' WIDEAND UNKNOWN IN LENGTH. THESE AREA HAD BEEN BOL TED WITH 6-8' RESIN BOLTS AND STRAPS. SUPPLEMENTSUPPORTS WERE INSTALLED IN AREA WHERE ROOF FAILURE WAS INDICATED. THIS WAS A DEFECTIVE AREA.
AFTER FINISHING FINAL PUSH-OUT STARTED MOVING MRS ROOF SUPPORTS. AS LAST TWO MRSS WERE BEING WALKED OUT LOST RADIO SIGNAL ON #4 MRS WHILE NOT PRESSURIZED. INTERSECTION FELL IN PINNING #4 MRS F OR 3 HRS. TRAILING CABLE DAMAGED REQUIRING ONE PERMANENT SPLICE.
WHILE THROWING CRIB BLOCKS EMPLOYEE HIT LEFT RING FINGER BETWEEN CRIB BLOCK HE WAS THROWING AND STANDING CRIB.
AN AREA OF SUBNORMAL ROOF FELL AT THE INTERSECTION OF 2RT AND #5 ENTRY OF SE MAINS SMACHING 2 SECTIONS OF 8" WATERLINE.
WHILE OPERATING A 550 EIMCO SCOOP IN THE #2 ENTRY OF THE 1 LEFT SECTION CORNER OF RIB FELL STRIKING EMPLOYEE ON ELBOW.
AN AREA OF SUB NORMAL ROOF IN THE #3 ENTRY OF THE IDLE-5 SOUTH SECTION FELL APPROX. 70' LONG X 18' WIDE X 12' TO 14' HIGH. THE AREA HAD BEEN SUPPORTED WITH 6' AND 8' RESIN BOLTS WITH T-3 STRAP S.
AN AREA OF SUBNORMAL ROOF FELL IN THE IDLE 5 SOUTH SECTION AND WAS FOUND ON A WEEKLY RUN WHEN MINE FOREMAN WENT TO PUT DANGER SIGNS ONOTHER FALLTHIS FALL MEASURED APPROX 20'L, 18'W, 12-14'H. THE AREA HAD BEEN SUPPORTED WITH 6-8' RESIN BOLT& T-3 CHANNELS.
AN AREA OF SUBNORMAL ROOF FELL, AT AN INTERSECTION IN THE NORTH EAST MAINS APPROX. 80' OUTBY SURVEY STATION 1342 THE FALL MEASURED APPROX. 17' WIDE BY 20' LONG X APPROX 10-14' HIGH. #2 ENTRY.
WHILE PULLING ON ROCK BAR, ROCK BAR SLIPPED STRKING EE ON RIGHT EAR, CAUSING CUT & CONTUSION RESULTING IN THE NEED FOR 11 STITCHES.
ROOF FALL OCCURRED IN NE BUTT BLEEDER IN #1 AND 2 ENTRIES IN INTERSECTIONS INBY SS 2111 IN #1 ENTRY AND INBY SS 2884 IN #2 ENTRY RESTRICTING EXAMINATION OF ENTIRE BLEEDER. FALL WAS 9-12'H FOR AN UNDETERMINED LENGTH. AREA HAD BEEN SUPPORTED WITH 6-8' RESIN BOLTS AND STRAPS.
AN AREA OF SUBNORMAL ROOF FELL JUST INBY SS#1932 THE FALL RAN FROM #8 ENTRY NORTHEAST BUTT THROUGH CONNECTING XCUTS TO #9, 10 ENTRY 150' LONG X 19' WIDE X 12-14' HIGH THIS AREA HAD BEEN BOLTED WITH 6' RESIN BOLTS AND STRAPS.
WHILE CUTTING DOWN LOOSE ROOF ROCK PIECE OF ROCK SLID DOWN ELEVATED CUTTER HEAD AND BOOM BACK UNDER OVER HEAD. SUPPORT BEAMS AND FELL OFF RIGHT SIDE OF MINER STRIKING OPERATOR ON RIGHT LEG AGA INST CRIB SUPPORTING BEAM BREAKING TIBIA AND FIBULA.
AN AREA OF #1 ENTRY NE MAIN S. INTAKE ESCAPEWAY APPROX 15' OUTBY SS#1097 FELL AT AN INTERSECTIONTHE FALL MEASURED APPROX 60'L, BY 19' W X 10-12 'H. THIS AREA HAD BEEN SUPPORTED WITH 6-8 ' RESI N BOLTS STRAPS & SOME SUPPLEMENTAL SUPPORTS INTHE FORM OF X-BARS & CRIBS
AN AREA OF UNCONSOLIDATED ROOF FELL INT HE 7 COMMON ENTRY. 1 X CUT INBY SS 2041 THIS AREA WAS BOLTED WITH 6-8' RESIN BOLTS AND STRAPS AND WAS TIMBERED OFF. THIS FALL OCCURRED IN THE N.E. BUTT ENTRY.
EE WAS TEARING DOWN OVERCAST WHEN I BEAM DROPPEDCATCHING RING FINGER BETWEEN I BEAM & CONCRETE BLOCK SMASHING RING FINGER
AN AREA OF ROOF FELL ABOVE THE LENGTH OF THE BOLTS IN THE #5 COMMON ENTRY OF THE NORTHEAST BUTT SECTION. THE FALL MEASURED APPROX. 40' LONG X 18' WIDE X 6-8' HIGH. APPROX. 40 OF HI VOLTAGE CABLE WAS LOST.
WHILE HANDLING 6" STEEL I BEAMS THE END OF WHICH WERE SETTING ON A CRIB BLOCK, I BEAM SHIFTED AND FELL ON EMPS FOOT CAUSING BRUISING AND SPRAIN.
A ROOF FALL OCCURED IN THE NORTH EAST MAINS #4 &5 ENTRIES IN THE AREA OF 1133 #4 ENTRY APPROX 70'L, X8' H, X 18' WIDE AND THE #5 ENTRY SS#1101APPROX 200'L, 8' H, X 18' WIDE THE AREA WAS BOLTED ON DEVELOPMENT WITH 6' RESIN BOLTS ON 4' CENTERS & ROOF MATS & CHANNELS.
A LARGE PORTION OF RIB SCALED OFF IN A HIGH AREA WHICH HAD CAVED AND BEEN CLEANED UP. THE PORTION OF RIB MEASURED APPROX. 50'LX2-3'WX12-13'H. THIS RIB WAS LOCATED ALONG THE NORTH EAST 1 BELT A T SURVEY STATION 1069. 3 SECTIONS OF BELT STRUCTURE AND 60' OF HI VOLTAGE CABLE DAMAGED.
THIS AREA HAD SHOWN SIGN OF FAILURE SOME CRIBS HAD BEEN SET. THE FALL WAS OFF SECTION AND MEASURED 18' W BY 40' L X 10-12' HIGH. THE FALL AREA HAD INITIALLY BEEN BOLTED WITH 6' AND 8' RESIN RO DS AND T-3 CHANNELS.
THERE WAS A ROOF FALL AT THE FACE OF THE IDLE #4 ROOM IN THE NORTH EAST BUTT ROOMS. THE FALL MEASURED APPROX. 18 FT WIDE BY 23 FT LONG BY 8 TO 10 FT HIGH. THE AREA WAS INITIALLY SUPPORTED BY 6 AND 8 FT RESIN BOLTS WITH T-3 CHANNEL STRAPS. REPORTED TO REG. INSPECTOR.
WHILE WORKING IN THE OPERATORS' COMPARTMENT OF A SHUTTLE CAR, MECHANIC WAS CHANGING POSITIONS AND GELT A PAIN IN LEFT KNEE. SUBSEQUENT VISIT TO A DR. INDICATED SPRAINED/STRAINED KNEE CARTILAGE .
WHILE DRILLING HOLE FOR ROOF BOLT EMPLOYEE WAS PUTTING 2ND PIECE ON BOTTOM OF DRILL STEEL. WHEN UP PRESSURE WAS APPLIED STEEL JUMPED OUT OF CHUCK STRIKIGN EMPLOYEE IN HAND. EMPLOYEE HAD FOR A PPROX 9 DAYS HE THEN WENT TO DR WHO APPLIED A SPLINT.
AN AREA OF SUBNORMAL ROOF MEASURING APPROX. 8' HIGH BY 18' WIDE BY APPROX 15' LONG FELL IN THE CROSSCUT BETWEEN THE 3 AND 4 RM IN THE 1 LEFT BLEEDER OFF THE 1ST LEFT SECTION BLEEDER.
EMPLOYEE STATED HE AHD PAIN IN RIGHT SHOULDER FOR QUITE A WHILE BUT IT WAS AGGRAVATED BY REPEATED BUMP IN SHUTTLE CAR ROADWAY. EMPLOYEE WENT TO SPECIALIST 1-27-97 AND WILL BE COMPLETING THERA PY.
WHILE PULLING STUCK MRS WITH MINER RETRIEVER EE USED A CHAIN SPREAD APART FORCING NUT OFF CLEVIS BOLTS. NUT FLEW STRIKING EMPLOYEE IN RIGHT CALF. EMPLOYEE RECEIVED STITCHES IN CALF OF RIGHT LEG.
1996 · 29 incidentes
WHILE SECURING A CHAIN BETWEEN A LOAD OF SUPPLIES AND SCOOP, EMPLOYEE FAILED TO GET FINGER CLEAR OF CHAIN BEFORE TIGHTENING UP, REQUIRING SEVERAL STITCHES TO TIP OF MIDDLE FINGER. EMPLOYEE RET URNED ON NEXT SCHEDULED SHIFT.
AN AREA OF ROOF APPROX 40' OUTBY SS#1334 SHEARED OFF APPROX 3 ROWS OF BOLTS FOR A DISTANCE OF 12' WIDE X 18' LONG AND 3' HIGH. THIS AREA CONSISTED OF DARK SHALE AND SANDROCK LAYERS AND WAS BVO LTED WITH 6' RESIN RODS AND 5-3 CHANNELS WHICH FAILED TO BUILD A BEAM.
WHILE DRIVING PIN ON MASTER LINK ON ROOF BOLTER CHAIN EE WAS POUNDING METAL AGAINST METAL WHEN PIECE OF STEEL SPALLED OFF STRIKING EE IN NECK. EE WENT TO HOSPITAL TO HAVE SLIVER REMOVED. DR DI D NOT REMOVE SLIVER, BUT ENLARGED WOUND TO NEED THREE STITCHES.
NOTE THIS FALL WAS DISCOVERED ON A WEEKLY EXAM. THE ROOF IN THIS AREA CONSISTED OF SHALE MIXED WITH SANDSTONE STREAKS. IT FELL IN INTAKE ESCAPEWAY WHICH WAS REROUTED. THE AREA OF FALL WAS IN AN INTERSECTION AND MEASURED APPROX. 25' LONG X 18' WIDE X 6 TO 7 FEET HIGH.
A GRADUAL GAGGING OF ROOF STARTED INT H UNBOLTED AREA OF #5 FACE 5 SOUTH SECTION AND EVENTUALLY FELL INTO THE LAST OPEN X-CUT 5-4 ENTRY INVOLVING BROWS OF ROOF BOLTS, SOM OF WHICH WERE 6' SOME 8' IN T-3 CHANNELS.
AN AREA OF SUBNORMAL SUBSTANDARD ROOF DETERIORATED AND FELL AFTER INITIAL DEVELOPEMENT. THIS AREA WAS IN THE PRIMARY INTAKE ESCAPEWAY. THIS AREA WAS BOLTED WITH 6' RESIN BOLTS AND T-5 CHANNELS . IT MEASURED APPROX. 30'X 20'X 10' TO 12' HIGH.AN ESCAPEWAY WILL BE CLEANED AND RE-SUPPORTED.
A ROOF FALL OCCURED FROM APPROX 30' INBY 55# 1288 TOO APPROX 40' OUTBY SS#1325 EXTENDING APPROX 70'. THIS FALLW AS IN THE PRIMARY INTAKE ESCAPE WAY WHICH WAS RE-ROUTED, ALSO THIS FALL WAS NOT WITNESSED BUT FOUND AFTER PRE-SHIFT.
A ROOF FALL OCCURRED IN THE #2 ENTRY NORTHEAST MAINS IN AN ACTIVE UNUSED AREA. THE FALL AREA HAD BEEN BOLTED WITH 6' RESIN AND T-5 CHANNELS. THIS FALL WAS DISCOVERED BY A MINE EXAMINER AT APPR OX. 0400.
A ROOF FALL WAS FOUND ON A WEEKLY RUN IN THE #4 ENTRY OF THE NORTHEAST MAINS. THE #4 ENTRY IS IN AN IDLE BUT ACTIVE AREA THE FALL MEASURED APPROX. 18' WIDE X 25' LONG FROM 6-8' HIGH. THERE WAS NO RESTRICTION OF VENTILATION OR EQUIPMENT NOR ANY INJURY OR DAMAGE.
EE WAS BOLTING WHEN HE BENT STEEL WHEN HE DROPPED BOLTER HEAD WITH HAND ON STEEL. STEEL SPRANG STRIKING EE ON RT POINTER FINGER. EE RECEIVED SPLINT ON FINGER MAKING IT REPORTABLE.
EMPLOYEE WAS USING A CRIB BLOCK TO POUND AND CAUGHT RIGHT INDEX FINGER BETWEEN CRIB ADN PIPE CAUSIN GFACTURE TO FINGER.
THIS IS FIRST SHIFT LOST BY EMPLOYEE. EE DIAGNOSED IWTH CARPAL TUNNEL SYNDROME IN BOTH WRISTS DUE TO REPETETIVE MOTION AND HAD RIGHT WRIST OPERATED ON 7/15/96 AND WILL HAVE LEFT WRIST OPERATED ON PRIOR TO RETURNING TO WORK.
A ROOF FALL APPROX. 50' LONG X 17' WIDE X 8' HIGH OCCURRED IN THE SOUTHEAST MAIN ENTRIES. FALL WAS LOCATED TO THE LEFT OF SURVEY STATION 256. FALL STARTED ON LEFT SIDE OF 1 ENTRY AND EXTEADED THRU CROSSCUT FROM 1 ENTRY TO LEFT ACROSS 0 ENTRY TO SOLID COAL. THERE WERE NO INJURIES AND NO PROPERTY DAMAGE.
A ROOF FALL OCCURRED IN THE #4 ENTRY OF NORTHEAST MAINS APPROX. 60' OUTBY SURVEY STATION #1453. FALL WAS APPROX. 18' WIDE X 16' LONG X 4' HIGH. THERE WERE NO INJURIES AND NO PROPERTY DAMAGE.
A ROOF FALL ABOUT 16" WIDE X 14' LONG X 6' HIGH OCCURRED IN THE CROSSCUT BETWEEN 2 AND 1 ENTRIES OF 4 SOUTH. THIS IS THE CROSSCUT AT 19 & 53. THERE WERE NO INJURIES AND NO PROPERTY DAMAGE.
INJURED PERSON WAS POSITIONED ALONG THE RIGHT SIDE OF A ROOF BOLTING MACHINE WHEN AN UNDETEDTED LOOSE RIB FELL STRIKING HIM AND KNOCKING HIM TO THE BOTTOM. WAS BRIEFLY PINNED BY RIB UNTIL FREE D BY COWORKERS. SUSTAINED MULTIPLE FACIAL FRACTURES, DISLOCATED RIGHT HIP, BROKEN RT FOOT, TWO BROKEN BONES IN LOWER LEG - RIGHT.
EE WAS TRAMMING A SCOOP LOADED WITH ROOF BOLTER SUPPLIES. AS THE SCOOP WAS TRAMMED UP OUT OF A HOLE THE BUCKET RAISED UP CAUSING SOME STRAPS & T-3 CHANNELS TO SLIDE, STRIKING THE OPERATOR'S LE FT HAND. HE SUSTAINED A BROKEN BONE IN LEFT THUMB AND SEVERE CUT.
A ROOF FALL OCCURRED IN THE #3 ENTRY AT 1ST LEFT OFF NORTHEAST MAINS AT SURVEY STATION NO. 1262. THE FALL WAS ABOUT 20' LONG BY 20' WIDE BY 6-7' HIGH. FALL COVERED AN IDLE BELT DRIVE. THERE DO ES NOT APPEAR TO BE ANY DAMAGE TO THE DRIVE.
THIS PERSON HAS BEEN DIAGNOSED AS HAVING CARPAL TUNNEL SYNDROME IN RIGHT HAND AND WRIST. WAS A ROOF BOLTER OPERATOR WHO ALWAYS OPERATED CONTROL LEVERS WITH RIGHT HAND. HAD SURGERY TO CORRECT T HIS CONDITION. PROGNOSIS IS CONSIDERED STABEL.
INJURD PERSON WAS HELPING UNLOAD A BELT DRIVE FROM A SCOOP BUCKET. HE WAS POSITIONED BETWEEN HE DRIVE FRAME AND THE SIDE OF THE SCOOP BUCKET WHEN THE CHAIN HOLDING THE DRIVE WAS LOOSENED. TH E DRIVE SLIPPED AND PINCHED HIS TORSO AGAINST THE SIDE OF THE BUCKET. HE SUSTAINED BLUNT TORSO TRAUMA AND A FRACTURED TRANSVERSE PROCESS.
A ROOF FALL OCCURRED IN THE #2 ENTRY OF NORTHEAST MAINS AT SURVEY STATION NO. 1071. THE FALL WAS ABOUT 8' HIGH X 17' WIDE X 25' LONG. THERE WERE NO INJURIES OR PROPERTY DAMAGE.
A ROOF FALL OCCURRED IN THE #3 ENTRY OF THE NORTHEAST MAINS (003-0) WORKING SECTION IN THE INTERSECTION AT 8+90. THE FALL WAS APPROX. 20' LONG X 17' WIDE X 7' HIGH. THERE WERE NO INJURIES. ABO UT 20' OF CONTINUOUS MINER TRAILING CABLE WAS DAMAGED.
THE INJURED PERSON WAS SWINGING A ROOF BOLTER BOOM FROM THE OUTSIDE BOLT TO THE INSIDE BOLT POSITION WHEN A PIECE OF RIB ROLLED OUT. THE FALLINGRIB STRUCK HIS LEFT HAND WHICH WAS POSITIONED ON THE DRILL STEEL TRAY. SUSTAINED A FRACTURED BONEBETWEEN KNUCKLE AND FIRST JOINT OF RING FINGER ON LEFT HAND.
A ROOF FALL OCCURRED IN THE #3 ENTRY OF 2 SOUTH AT SURVEY STATION #225. THE FALL MEASURED APPROX50'L, 17'W, 7' TO 8'H. THERE WAS NO DAMAGE TO PROPERTY OR EQUIPMENT.
A ROOF FALL OCCURRED IN THE 5 ENTRY OF 2 SOUTH AT SURVEY STATION 1174. THE FALL WAS APPROX. 9' HIGH X 16' LONGX 17' WIDE. THERE WAS NO DAMAGE TO PROPERTY OR EQUIPMENT.
A ROOF FALL OCCURRED IN THE NO.3 ENTRY OF 3 SOUTH SECTION JUST OUTBY 29 & 10 THE FALL WAS APPROX. 100 FT LONG X 18 FT WIDE X AT LEAST 18 FT HIGH THE CONTINUOUS MINER AND 1 BRIDGE WERE DAMAGED.
INJURED PERSON WAS USING A LIFTING JACK TO SDJUST THE POSITION OF BUNDLE OF ROOF BOLTS ON RAIL SUPPLY CAR. DOG IN JACK MECHANISM DIDN'T CATCH CAUSING HANDLE TO FLY UP STRIKING HIM ON THE RT CH EEK. FOUND SMALL PIECE OF ICE IN JACK MECHANISM.SUSTAINED A BLUNT FORCE LACERATION REQUIRING 20 STITCHES TO RT CHEEK.
A ROOF FALL OCCURRED IN A CROSSCUT BETWEEN #4 & #5 ENTRIES OF NE MAINS ADJACENT TO SURVEY STATION #544. FALL MEASURED ABOUT 70'L,18'W,12-15'H. THERE WAS NO DAMAGE TO PROPERTY OR EQUIPMENT.
INJURRE PERS ON WAS TRAMMING CONTINUOUS MINER THROUGH CROSSCUT. SHUT OFF MACHINE AND STARTED WALKING TO LOCATION WHERE HE COULD SEE THE TAIL MORE CLEARLY. WHILE LOCATED BETWEEN RIB AND HEAD OF MINER HE WAS PINCHED. SUSTAINED A PUNCTURE WOUNDTO RT THIGH AND BRUISED MUSCLES IN PELVIS\GROIN AREA. PUNCTURE WOUND REQUIRED STITCHES.
1995 · 17 incidentes
THIS PERSON HAS MINER'S KNEE (WATER ON THE KNEE) HIS PHYSICIAN STATED THAT THIS WAS CAUSED BY WORKING ON HIS KNEES A LOT. NO SPECIFIC INDIDENT WAS INVOLVED. HE HAD THE LEFT KNEE DRAINED AND AL SO RECEIVED A SHOT OF CORTISONE.
INJURED PERSON WAS LAYING UNDER NEATH A CONTINUOUS MINER BURNING OVERHEAD WITH A TORCH WHEN A SPARK FLEW INTO HIS RIGHT EAR. THIS CAUSED A HOLE IN EAR DRUM.
A ROOF FALL OCCURRED IN THE 2 SOUTH SECTION 3 ENTRY APPROX. 80' LONG 20' WIDE AND 6' HIGH AND EXTENDED INTO X CUT 3 TO 4. THIS IS AN INCACTIVE SECTION. NO EQUIPMENT OR PROPERTY DAMAGE OCCURRED .
A ROOF FALL OCCURRED IN #1 ENTRY OF A BUTT ENTRIES IMMEDIATELY INBY SURVEY STATION NO. 1126. THE FALL WAS APPROX. 35' LONG X 20' WIDE 5' HIGH. IT DID NOT CAUSE ANY DAMAGE TO PROPERTY OR EQUIPM ENT.
A PIECE OF ROCK MEASURING 36" WIDE X 43" LONG X 2-8" THICK SLID OFF AN OVERCASE WINGWALL AS THE WALL WAS BEING REMOVED. THE ROCK HIT A POST AS IT WAS FALLING AND BOUNCED ONTO THE INJURED PERSO N LEFT ANKLE HE SUSTAINED A FRACTURE OF TWO BONES IN LEFT ANKLE.
THE INJURED PERSON WAS REACHING ACROSS A ROOF BOLTILNG MACHINE TO PICKUP TWO TUBES OF RESIN WHENHE SUDDENLY EXPERIENCED PAIN IN BACK ON LEFT SIDE. HE SUSTAINED MUSCLE SPASMS.
A ROOF FALL OCCURRED IN THE 3 ENTRY OF SOUTHEAST MAINS. THE FAD WAS APPROX. 60'X20'X6' THE FALL ALSO EXTENDED APPROX. 10' OUT INTO THE X CUT LEFT AND RIGHT OFF THE INTERSECTION OF THE FALL THE RE WERE NO INJURIES. APPSOX. 60' OF EACH OF THE FOLLOWING WERE DAMAGED WATERLINE STOP START CABLE AND PULL COND, BELT, BELT STRUCTURE FIRE SEASON AND PHONE LINE.
THE INJURED PERSON WAS CLEANING ROCK OFF THE CONTINUOUS MINER WHEN A PIECE OF ROCK MEAUSRING ABOUT 6" LONG X 6" WIDE X 2" THICK FELL AND STRUCK HIM ON THE RIGHT HAND THE ROCK FELL FROM A PERMA NENTLY SUPPORTED AREA AND THE INJURED PERSON WASLOCATED IN A PERMANENTLY SUPPORTED AREA.
A ROOF FALL OCCURRED IN THE NO.2 ENTRY OF THE NORTHEAST MAINS AT SURVEY STATION NO.1072. THE FALL WAS APPROXMATELY 18' LONG X 17' WIDE X 9' HIGH. THERE WERE NO INJURIES. THE FALL DAMAGED ABOUT 18' OF HIGH VOLTAGE CABLE.
A ROOF FALL OCCURED IN THE #3 ENTRY OF 1ST SOUTH BUTT, IMMEDIATELY INBY SURVEY STATION #559. TEH FALL WAS APPROX 20 FT LONG X 15 FT WIDE X 7 FT HIGH. THERE WERE NO INJURIES. ABOUT 20 FT OF BEL T SIDE RAILS WERE LOST UNDER FALL.
A ROOF FALL OCCURRED IN A CROSSCUT BETWEEN #1 ENTRY AND #2 ENTRY IN 7 RIGHT SECITON. THIS WAS IN TEH FIRST CROSSCUT INBY SURVEY STATON #1015 IN #1 ENTRY. THE FALL WAS APPROX 18'W X70'LX6'H. T HERE WAS NOT PROEPRTY DAMAGE.
A ROOF FALL OCCURRED APPROX 50FT OUTBY SURVEY STATION NO 1013 IN #2 ENTRY OF 7 RT THE FALL WAS APPROX 18FT LONG X`18FT WIDE X6FT HIGH THERE WAS NO PROPERTY DAMAGE
INJURED WAS THROWING A PIECE OF BOTTOM-STANDING BELT STRUCTURE WHEN ONE OF THE FEET ON THE STRUCTURE CAUGHT HIS RIBS. HE SUSTAINED A FRACTURE TO A LEFT SIDE RIB NEAR BASE OF RIB CAGE.
INJURED PERSON WAS MOVING A PUMP. AS HE WAS PULLING UP ON A ROCK BAR WHICH WAS INSERTED THROUGH AN EYE ON PUMP HE FELT PAIN IN RIGHT HIP. HE SUSTAINED A SPRAIN WHICH REQUIRED TREATMENT BY A CH IROPRACTOR.
INJURED PERSON PUSHED OPEN A BELT CHECK TO EXIT A CANOPY AT THE MINE PORTAL. AS HE WAS PUSHING THE BELT SLID BETWEEN HIS RING AND LITTLE FINGER INFLICTING A CUT ON LITTLE FINGER OF LEFT HAND THIS CUT REQUIRED 5 STITCHES.
INJURED PERSON WAS HELPING REMOVE A BELT TAILROLLER. ONE SIDE OF THE ROLLER HAD BEEN LOOSENED AND THE INJURED PERSON THOUGHT THAT IT WAS SITTING ON THE FRAME OF THE BELT TAIL. WHEN HE LIFTED O N THE OPPOSITE SIDE THE SIDE WHICH HAD BEEN LOOSENED FELL PINCHING HIS FINGERS HE SUSTAINED A BROKEN BONE IN THE LITTLE FINGER AND CRACKED BONE ON RING FINGER RIGHT HAND.
INJURED PERSON THREW A LIFTING JACK ONTO A 3 WHEEL MANTRIP. AS THE JACK CAME DOWN THE HANDLE STRUCK A SPARE TIRE PINCHING HIS LEFT RING FINGER IN THE HINGE RATCHET MECHANISM OF THE JACK. HE SU STAINED A BRUISED FINGER WITH A CRACKED BONE.
1994 · 28 incidentes
EE WAS STANDING ON THE SECTION BELT (LOW AREA ON RFM) THROWING SOME ROCK OFF. WHEN HE FINISHED AND STARTED STEPPING DOWN OFF BELT HE SLIPPE AND FELL. AS HE FELL HIS CAP LAMP BATTERY STRUCK THE FRAME OF THE RFM AND JAMMED INTO HIS LEFT BUTTOCKS. HE SUSTAINED A LOW BACK INJURY.
INJURED PERSON WAS THROWING A PIECE OF TOP BELT STRUCTURE ACROSS AN OLD BELT AS HE TOSSED THE STRUCTURE HIS GLOVE CAUGHT ON THE END OF THE STRUCTURE FORCING THE END OF THE STRUCTURE AGAINST TH E ROOF. THIS ACTION PINCHED THE MIDDLE FINGER ONHIS RIGHT HAND BETWEEN THE ROOF AND STRUCTURE. FINGER WAS BRUISED AND CUT. IT REQUIRED 5 STITCHES.
INJURED PERSON , A BOLTER OPERATOR WAS INSTALLING AN INSERT IN THE ROOF BOLTING MACHINE DRILL CHUCK. A DRILL STEEL WHICH HAD BEEN STUCK IN A BOLT HOLE FELL OUT OF THE HOEL SMASHING HIS LEFT RI NG FINGER AGAINST THE INSERT. HE SUSTAINED A FRACTURED BONE IN THIS FINGER BETWEEN THE FIRST AND SECOND JOINTS.
INJURED PERSON WAS WALKING THRU ON EQUIPMENT DOOR WHEN HE STRUCK HIS HEAD ON THE OVERHEAD POPTION OF THE DOOR FRAMEWORK. HE SUSTAINED AND NECK AINJURY WITH POSSIBLE DISC TROUBLE. HE IS RECEIVI NG TREATMENTS FROM A CHIROPRACTOR.
INJURED PERSON WAS TWISTING A PIECE OF STANGDED MINER CABLE WITH HIS RIGHT HAND IN PREPARATION FOR ENTERING IT INTO A NIP. AS HE TWIST3D A STAND OF THE TRAILING CABLE WIRE MADE A SMALL PUNCTUR E WOUND IN HIS RIGHT THUMB. THIS WOUND BECAME INFECTED. HE IS RECEIVING TREATMENT FOR INFECTION.
THE INJURED PERSON WAS OEPRATING A BATTERY POWERED SCOOP WITH HIS LEFT HAND PLACE DON THE FRAME OUTSIDE TH EOPERATOR'S COMPARTMENT. AS HE HAD A TURN HSI HAND WA SPINCHED BETWEEN THE BRAMES OF HTE FRONT AND REAR SCOOP SECTIONS. HE SUSTAINED A BROKEN BONE BETWEEN 2ND JOINT AND KNUCKLE ON TEH LITTLE FINGER OF THIS HAND.
WHILE REPAIRING AN MRS TRAILING CABLE THE INJURED PERSON WAS STRUCK BY A PIECE OF ROCK WHICH HAD FALLEN OUT BETWEEN THE INSTALLED ROOF BOLS THE INJURED PERSON WAS LOCATED IN A BOLTED AREA WHEN STRUCK THE ROCK MEASURED 5FT LONG X2FT WIDE X0FT TO 4IN THICK HE SUSTAINED BLANT CHEST TRAUMA A SPRAINED CHEST & ABRASION ON RT SHOULDER
WHITE HELPING REPAIR ON MRS TRAILING CABLE THE INJURED PERSON WAS STRUCK BY A PIECE OF ROCK WHICH HE FALLEN OUT BETWEEN THE INSTALLED ROOF BOLTS. THE INJURED PERSON WAS LOCATED IN A BOLTED ARE A. WHEN STRUCK. THE ROCK MEASURED 5FT X 2 FT WIDE X 4 INCH THICK.
A ROOF FALL OCCURED IMMEDIATELY OUTBY SURVEY STATION NO 636 IN THE NO 2 ENTRY OF 1ST SOUTH. THE FALL WAS APPROX. 20' LONG X ABOUT 20' LONG WAS DAMAGED.
A ROOF FALL OCCURRED IN THE #1 ENTRY OF 1ST SOUTH. THE OUTBY EDGE OF THE FALL WAS BOUT 40' INBY SURVEY STATION NO. 622. THE FALL WAS ABOUT 100' X 10' X 18'. THERE WAS NOT PROPERTY DAMAGE.
EMPLOYEE WAS DISPENSING LIQUID SOAP FROM SQUIRT DISPENSER WITH A BROKEN NOZZLE WHEN HE INADVERTENTLY SQUIRTED HIMSELF IN EYES. EMPLOYEE RECIEVED PRESCRIPTION EYE DROPS. EMPLOYEE TOOK 2 DAYS OF F NOT RELATED TO ACCIDENT.
A ROOF FALL OCCURRED IN THE #3 ENTRY OF NORTHEAST MAINS. THE OUTBY EDGE OF THE FALLW AS LOCATED ABOUT 30' INBY SURVEY STAITON NO. 542. THE FALL WAS ABOUT 7' H X30' LX 18' WIDE. THERE WAS NO PROPERTY DAMAGE.
INJURED PERSON WAS CARRYING TWO ROOF BOLTS TO FRONT OF ROOF BOLTING MACHINE WHEN HE TRIPPED OVER A PIECE OF ROCK CAUSING HIM TO FALL AGAINST RIB STRICKING LEFT SHOULDER HE SUSTAINED A CONTUSIO N TO LEFT SHOULDER
EE STARTED MISSING WORK ON 6-2-94 AND MISSED A TOTAL OF 51 DAYS. THIS ABSENCE WAS CAUSED BY AN INJURY HE SUSTAINED ON 4-13-94 IN THE DIAMOND T B MINE. A COPY OF THE 7000-1 REPORT ON 4-13 INJUR Y IS ATTACHED.
THE INJURED PERSON WAS LIFTING A BAR WITH A PIECE OF BELT CHAIN ATTACHED TO THE BAR THE END OF THE BELT CHAIN CAUGHT ON A PIECE OF LINE BRATTICE WHICH CAUSED HIS RT ARM & WAIST TO BE TWISTED H E SUSTAINED SOME INFLAMMATION OF TENDONS IN RT ELBOW & ALSO STRETCHED TENDONS
A ROOF FALL OCCURRED IN THE #4 ENTRY OF THE SOUTHEAST MAINS ADJACENT TO SURVEY STATION 92. THE ROOF FALL DIMENSIONS ARE APPROX 18'WIDE AND 30' LONG X6' HIGH. THERE WAS NO PROPERTY DAMAGE.
A ROOF FALL OCCURRED JUST INBY SURVEY STATION NO. 206 IN THE F2 SUMP ROOM OF 2 RIGHT. THE FALL WAS ABOUT 7 FEE THIGH X 17 FEET WIDE X 60 FEET LONG. THERE WAS NO PROPERTY DAMAGE.
A ROOF FALL OCCURED IN THE #2 ENTRY OF 5 RIGHT SECTION. THE OUTBY EDGE OF THE FALL WAS LOCATED APPROX 50' INBY SURVEY STATION NO. 677. FALL WASABOUT 17' WIDE X 8' HIGH X 100'LONG. APPROX 100 ' OF HIGH VOLTAGE CABLE WAS DAMAGED.
A ROOF FALL OCCURRED IN THE #3 ENTRY OF THE 5 RT SECTION THE OUTBY EDGE OF THE FALL WAS LOCATED AT 5 UAVY STA NO 703 FALL WAS ABOUT 17FT WIDE AT THE OUTBY END BY ABOUT 40FT LONG HEIGHT VARIED FROM APPROX 6FT AT OUTBY END TO ABOUT 24FT AT INBY END ABOUT 40FT OF BELT BELT STRUCTURED JOBCO POWER CABLE & WATER LINE WERE DAMAGED
INJURED PERSON WAS PULLING MINER CABLE OUT OF ROADWAY WHEN HE STARTED HAVING PAIN IN HIS BACK HE SUSTAINED A LOWER BACK STRAIN
INJURED PERSON WAS ATTEMPTING TO MOVE THE MINER CABLE WHEN HE FELL TO THE GROUND HOLDING HIS LOWER BACK AND COMPLAINING OF EXTREMELF SHARP PAIN IN HIS LOWER BACK. HE SUSTAINED PULLED MUSCLES A ND A SPRAIN OF LOWER BACK.
A ROOF FALL OCCURRED IN THE #2 ENTRY OF 1ST SOUTH BETWEEN SPADS 555 AND 562. THE FALL IS APPROXIMATELY 60' LONG X 20' WIDE X 8' HIGH. ABOUT 60' OF HIGH VOLTAGE CABLE AND TWO PUMP POWER CABLES WERE DAMAGED IN THIS FALL.
A ROOF FALL OCCURRED IN THE #3 ENTRY & CXROSSXUT RT FRAOM #3 ENTRY EXTENDING TOWARD +5 ENTRY IN THE 5RT SECTION THE FALL EXTENDED FROM ABOUT 80FT INBY SURVEY STA #679 IN #3 ENTRY INBY ABOUT 50 FT & TO THE RT THROUGH THE X-CUT FOR ABOUT 50FT THE HEIGHT VARIED FROM ABOUT 6FT 20FT HIGH X16FT TO 18WIDE THERE WERE NO INJURIES & NO EQUIPMENT WAS DAMAGED
INJURED PERSON WAS HELPING DRAG A WATER PUMP WHEN HE NOTICED SOMETHING HURTING ON LOWER RIGHT SIDE OF ABDOMEN.HE SUSTAINED ABDOMINAL HERNIA.
THE INJURED PERSON WAS WALKING TO HIS WORKING SECTION WHEN HE SLIPPED ON UNEVEN NOIST MINE FLOOR. HE DID NOT FALL BUT HE DID SUSTAIN A LUMBAR STRAIN CAUSED BY HIS EFFORTS TO KEEP HIM FALLING.
INJURED EE WAS HOOKING UP A CHAIN AROUND A PALLET OF CRIBS WHICH WERE GOING TO BE PULLED OFF A RAIL SUPPLY CAR ONTO A SCOOP. WHEN THE SCOOP OPERATOR TIGHTENED THE CHAIN, THE EE CAUGHT THE TIP OF HIS LITTLE FINGER ON RIGHT HAND BETWEEN CHAINAND CRIBS. HE SUSTAINED A SMASHED END OF LITTLE FINGER WHICH TOOK STITCHES.
A ROOF FALL APPROXIMATELY 20' WIDE X 40' LONG X 8' TO 9' HIGH OCCURRED IN THE #3 ENTRY OF 1ST SOUTH. THIS FALL WAS LOCATED AT STATION #550. THE FALL DAMAGED ABOUT 40' OF BELT STRUCTURE, BELT & JABCO CABLE. IT DID NOT CAUSE ANY INJURIES.
A ROOF FALL APPROXIMATELY 40' LONG X 8' HIGH X 16'-25' WIDE OCCURRED IN THE #5 ENTRY NORTHEST MAINS. THE OUTBY EDGE OF THE FALL IS LOCATED ABOUT 10' INBY STATION NO. 539. THIS FALL DID NOT CAU SE ANY INJURIES & NO EQUIPMENT WAS DAMAGED.
1993 · 21 incidentes
A ROOF FALL APPROX. 120' LONG X 16' WIDE X 6' HIGH OCCURRED INT HE #3 ENTRY OF 2ND RIGHT SLUMP. THIS FALL DID NOT CAUSE ANY INJURIES AND NO RQUIPMENT WAS DAMAGED.
THE INJURED PERSON WAS ATTMPTING TO LIFT A 4X8 WOODEN DOOR. THE WORK AREA WAS PITCHED STEPPLY AND VERY SLIPPERY. AS HE WAS LIFTING HE SLIPPED SLIGHTLY PULLING SOME MUSCLES IN HIS LOWER BACK.
A ROOF FALL OCCURRED IN THE 3 SUMP FROOM DRIVEN LEFT OFF OF 3RD RIGHT THE SIZE OF THE FALL IS ABOUT 130FT LONG X 16 FT WIDE X 5 TO 8 FT HIGH FOUR SECTION OF BELT STORAGE UNIT WERE DAMGED BY TH E FALL.
A ROOF FALL ABOUT 30'LX18'WX4 1/2' HIGH OCCURREDIN THE #3 ENTRY OF THE MAINS. THIS FALL WA SLOCATED AT STATION 266. THIS FALL DAMAGED THE MAIN BELT CONVEYOR, HIGH VOLTAGE CABLE AND OTHER POW ER CABLES.
DIET FELL STRIKING INJURED PERSON IN LEFT EYE AS HE WAS HANGING A CABLE UP ON AN INSULATOR. THIS CAUSED A SCRATCH OF LEFT EYE UNDER LID.
A ROOF FALL APPROX. 70' LONG X 16' WIDE X 5' TO 7' HIGH OCCURRED IN THE #1 ENTRY OF 3 RIGHT SECTION. THE OUTBY EDGE OF THE FULL IS LOCATED ABOUT 10' INBY STATION NO.15+74.
A ROOF FALL APPROX. 40' LONG X 20' WIDE X 6.5' HIGH AT PEAK OCCURRED IN THE FIRST INTERSECTION OUTBY STATION #269 IN #2 ENTRY OF B MAIN. THIS FALL EXTENDED INTO THE ADJACENT CROSSCUT.
A ROOF FALL APPROX 100' LONG X 20' WIDE X 6 1/2' HIGH, OCCURRED IN THE #3 ENTRY OF 3 RIGHT SECTION. THIS FALL WAS LOCATED ABOUT 800' OUTBY THE WORKING FACERS. IT STARTED AT SURVEY STATION #305 & EXTENDED INBY.
A ROOF FALL MEASURING APPROX. 7 FT HIGH X 20 FT WIDE OCCURRED ABOUT 120 FT INBY SURVEY STATION 202 IN THE 2 ENTRY OF 2ND REIGHT SECTION THIS WAS A CONTINUATION OF THE PILLAR FALL IN 2ND RIGHT WHICH CONTINED OUT INTO THE MAIN RETURN.
INJURED PERSON WAS POUNDING ON A HAMMER WITH ANOTHER HAMMER IN AN ATTEMPT OT REMOVE A NAIL FROM A SET OF STEPS. A SMALL PARTICLE BROKE OFF THE FIRST HAMMER AND THIS FYLING PARTICLE ENTERED HIS RIGHT THUMB. HE SUSTAINED A PUNCTURE WOUND AND CUT TENDON. THIS PERSON WAS WEARING GLOVES AT TIME OF ACCIDENT.
INJURED PERSON WAS INSTALLING A ROOF BOLT ON THE RIGHT SIDE OF A TWIN BOOM BOLTER WHEN A PIECE OF ROCK FELL INBY THE PRESSURIZED ATRS BEAM. THIS ROCK STRUCK THE BOTTOM AND BOUNCED OUTBY STRIKI NG THIS BOLTER OPERATOR ON THE LEFT ANKLE. HE SUSTAINED A BAD BRUISE.
EE WAS WORKING ON A PUMP WHEN HE STRUCK A HAMMER WITH A CHISEL THE HAMMER GLANCED OFF THE CHISEL WHICH CAUSED A PIECE OF THE HAMMER HEAD TO ENTER HIS RIGHT THUMB AND THE HAMMER TO STRIKE HIS L EFT HAND HE SUSTRAINED A CUT TO LEFT HAND AND SMALL PUNCTURE WOUND TO RIGHT THUMB.
EMPLOYEE WAS WALKING BETWEEN THE RIB AND BELT ON THE TIGHT SIDE WHEN THE RIB PUSHED OUT AND STRUCK HIM FORCING HIKM TO THE BOTTOM. HE SUSTAINED A FRACTURED LEFT RIB, PUNCTURED LUNG, LACERATIO NS OF FACE, FRACTURED SHOULDER BLADE, FRACTURED VERTEBRAE, FRACTURED LEFT LOOT AND CUT BEHIND EAR.
A ROOF FALL MEASURING ABOUT 30 FT LONG X 20 FT WIDE X 7.5 FT HIGH OCCURRED IN THE 2 ENTRY OF 2ND RIGHT SECTION THE OUTBY EDGE OF THE FALL WAS LOCATED ABOUT 10 FT INBY 9&00. THE MINER 1026 JEFF NEY RECEIVED DAMAGE TO 3 LIGHTS AND SOME LIDS BENT.
A ROOF FALL MEASURING ABOUT 20' LONG, 6' HIGH & 16' WIDE, OCCURRRED IN #1 ENTRY OF 1ST RIGHT SECTION. THIS IS NOT AN ACTIVE SECTION. NOTE: THE FALL OCCURRED SOMETIME BETWEEN 8 AM ON 4/20/93 AN D 1 AM ON 4/21/93.
UNCONSOLIDATED LAYERS OF SHALE AND SANDSTONE FAILED TO CONSTRUCT A SUPPORTIVE BEAM. AN AREA 80' LONG 16' WIDE 8' HIGH FELL IN CROSS CUT IN OUTBY SUMP AREA. 4 FT AND 6 FT RESIN GROUTED RODS WIT H T-5 CHANNELS WERE USED AS SUPPORT LOCATED IN 1 RT #3 SUMP ROOM.
AN AREA 20' WIDE 60' LONG BY 5' TO 8' HIGH FELL IN THE 1RT SECTION #3 ENTRY. UNCONCOLIDATED LAYERS OF SHALE AND SANDSTONE FAILED TO CONSTRUCT A SUPPORTIVE BEAM.4' TORQUE-TENSION RESIN BOLTS & 6' RESIN GROUTED RODS WERE USED.
THE INJURED PERSON WAS STANDING FACING THE CONTROLS FOR THE ATRS ON A TURN BOOM BOLTER WHEN A PIECE OF ROCK FELL FROM ROOF AND STRUCK HIM ON BACK. HE WAS LOCATED UNDER PERMANENT ROOF SUPPORTS. WHEN STRUCK HE FELL FORWARD AND STRUCK THE BOLTER. HE SUSTAINED A CUT CHAIN, BRUISED JAW & BRUISED BACK.
THE INJURED PERSON STEPPED DOWN OFF TE SIDE OF MINER (CONTINUOUS MIENR) WHICH WAS STOPPED AFTER HAVING CHECKED A PART AND TWISTED HIS LEFT ANKLE AS HE PLACED HIS FOOT ON THE BOTTOM.
UNDUE PRESSURE IN THIS AREA CAUSED ROOF FALL-AREA WAS BOLTED WITH 6' RESIN GROUTED RODS-5X7 WOOD CROSSBARS SUPPORTED WITH POSTS USED AS SUPPLEMENTARY SUPPORT 1 RT SECTION #2 ENTRY AT STA 11+72 .
WHILE RAISING BELT WITH RACHET JACK REACHED IN WITH LEFT HAND TO THROW UP-DOWN TOGGLE HANDLE SLIPPED OUT PINCHING HAND REQUIRING 10 STITCHES.
1992 · 13 incidentes
AREA OF SHALE AND SANDSTONE LAYERS WITH A MUDSLIP ABOVE FELL ABOVE BOLTS APPROX. 8 FT HIGH X 70 FT LONG COVERING MACHINE CABLES STARTING IN THE 3 ENTRY AT 17 & 50.
EE WAS WALKING IN THE C PIT BOTH FOOT SLIPPED ON ICE. HIS RIGHT FOOT CAUGHT ON SOME GRAVEL AND EE HEARD HIS ANKLE SNAP.
AN AREA OF ROOF APPROX. 70 FT LONG BY 18 FT WIDE FELL TO A HEIGHT OF APPROX. 7 FT THIS AREA CONSITED OF LAMINATED SHALE BOLTED WITH 4 FT RESIN RODS ON 4 FT CENTERS WITH 6 FT RESIN RODS RADNOML Y SPOTTED.
AN AREA OF LAMINATED SHALE INDESPENSED WITH WEAKSANDSTONE FELL APPROX 60' WIDE TO A HEIGHT OF APPROX 7'. THE AREA WAS BOLTED WITH 4' RESIN BOLTS ON 4' CENTERS WITH 6' SESIN RANDOMLY SPOTTED.
A ROOF FALL 40'LX16'WX8'H. SHALE, LAMINATED SAND STONE, COAL RIDER.
A LOOSE RIB FELL STRIKING EMPLOYEES RIGHT HAND-HIS HAND SWELLED AND THE SKIN BETWEEN HIS FINGERS SPLIT. EMPLOYEE GOT AN INFECTION IN HIS HAND AND WAS TREATED FOR AN INFECTION.
UNDUE PRESSURE IN THIS AREA CAUSED THE ROOF TO BREAK UP AND FALL. THE ROOF WAS SUPPORTED WITH 4' AND 6' FULLY GROUTED RESIN RODS.
UNDUE PRESSURE IN THIS AREA CAUSE THE ROOF TO BREAK UP AND FALL, THE ROOF WAS SUPPORTED WITH 4' AND 6' FULLY GRANTED RESIN RODS.
EMPLOYEE WAS LIFTING A CROSS BAR AND FELT PAIN IN LOWER BACK.
WHILE SWINGING RIGHT SIDE BOOM FOR OUTSIDE BOLT CANOPY STRUCK ROOF AND CAME OFF SAFETY POST JACK STRIKING HELPER ON RIGHT SIDE EAR SHOULDER AND BACK.
EMPLOYEE AFTER DRILLING 1/2 BOLT HOLE LOST DRILL CHUCK WRENCH WHEN EMPLOYEE DROPPED BOOM TO REPLACE WRENCH STEEL FELL OUT OF ROOF STRIKING RIGHT MIDDLE FINGER RECIEVED TEMPORARY SPLINT ON FING ER.
SHOVELING MAIN BELT PAIN IN L SIDE OF CHEST
BRIDGE BACKING OUT CAUGHT CRIB BLOCK BETWEEN FOOT