ENTRY HAD BEEN A WORKING FACE,BUT WAS STOPPED 3 DAYS EARLIER. THIS WAS DUE TO WORKING TOWARDS OUTCROP. THIS IS NO LONGER AN IMMEADIATE WORKING AREA. 150' INBY SPAD 2151 ON 1" RIGHT PANEL,OFF # 2 WEST MAIN.
Campbells Creek No 3 Coal
Registro de la MSHA sobre Campbells Creek No 3 (ID de mina 4608256). Muertes, incidentes no mortales agrupados por año, operador y controlador actuales, y contexto de la mina.
Seguir esta mina
Avísenme cuando se presente un nuevo incidente de la MSHA en Campbells Creek No 3.
- Muertes
- 0
- Incidentes totales
- 15
- Años en registro
- 1993–1998
- Último incidente
- Mar 1998
Incidentes reportables
15 en archivo1998 · 2 incidentes
SHOVELING COAL ALONG BELTWAY & PAIN IN LEFT SHOULDER & ARM,COMPLETED SHIFT. DIAGNOSIS WAS ROTATOR CUFF TEAR LEFT SHOULDER,,BY BRUCE F. HAUPT M.D..
1997 · 6 incidentes
CINDER BLOCKS WERE BANDED & WHEN BAND WAS CUT A CINDER BLOCK ROLLED OFF & STRUCK RIGHT FOOT.
BELIEVED TO STARTED IN ABANDONED PANEL OF ROOMS, APPROX. 600' FROM WORKING FACES. A ERIES OF FALLS RODE OUT OF THE ROOMS, DIAGNOSALLY, AND CAUGHT THE SECTION BELT HEAD AND 120' EACH DIRECTION ON THE BELT LINE. ALL PERSONNEL AND FACE EQUIPMENTS WERE NOT INVOLVED AREA HAS BEEN SECURED AND WILL BE PEIMANTLY SEALED.
FALL OCCURED IN 6 ENTRY IN THE INTAKE. APPROX. 5'-10' HIGH BY 30' LONG. SLATE TOP. FALL IS APPR 2200' FROM WORKING FACE. LOCATION IS ONE 3/T INBY SPAD 1541. HAVE ADJOINING ENTRY AS INTAKE AS W ELL NO VENETALITION RESTRICTIONS.
FALL OCCURRED 50' OUTBY SPAD 1641. FELL APPROX. 40' X 20' X 6'. SETTING 48" RESIN BOLTS.
FALL OCCURRED INTERSECTION IN 5 ENTRY IN MAIN INTAKE APPROX. 1100 FEEL FROM WORKING FACE. FALCE APPOX 60'X20'X5. FELL AT SPAD 1559 IN SOUTH MAINS.
LALMINATED SLATE TOP FELL AT SPAD #1629 IN NORTHWEST MAINS. FELL ABOVE ANCHORAGE. APPOX 60'L X 20'W, X 10'H. FELL IN INTERSECTION. ROCK ALSO FELL ON SC.
1996 · 2 incidentes
WORKING INSTALLING A BELT EXTENSION. LIFTED CONVEYOR RUBBER TO INSTALL RETURN IDLERS AND FELT SHARP PAIN IN LOWER BACK.
FALL DISCOVERED 7-2-96 #1 ENTRY SPAD #1319 APPROX. SIZE 6 FEET THICK 10 FEET WIDE X 70 FEET LENGTH. FALL OCCURRED 120' OUTBY ACTIVE SECTION. PERIMETER OF AREA IS TIMBERED AND DANGERED OFF. FAL L DID NOT INTERFERE WITH VENTILATION.
1995 · 1 incidente
A ROOF FALL WAS FOUND BY FOREMAN 3-22-95, 10:00AM ON THE NORTH MAINS IS 001-0 IN #2 ENTRY RETURN. AIR OR PASSAGE WAY IS NOT OBSTRUCTED. AREA WAS BOLTED WITH 4' RESIN RODS & AREA WAS CRIBBED AN D TIMBERED WHICH FALL RODE THIS DOWN. SIZE OF FALL: 61/2' THICK, 20' WIDE, 40' LENGTH. FALL AREA TIMBERED & DANGERED OFF. REPORTED TO MSHA MT. CARBON & WV DEPT OF MINES BY PHONE 3-22-95 12:00
1994 · 2 incidentes
WHILE MOVING MINER CABLE A PIECE OF DRAW ROCK SLID OFF A BOLTED METAL STRAP STRIKING INJURED BETWEEN TE SHOULDERS. HE CONTINUED TO WORK THE REMAINDER OF HIS SHIFT 3:45 PM & WORKED 8 3/4 HRS O N 6-24-94. & MINES WAS IDLE FROM 6-25-94 TO 7-5-94 FOR VACTION. RECEIVED A COMP CLAIM 7-5-94.
MAINTENANCE WAS INSTALLING A PIVOT PIN ON THE CONVEYOR BOOM OF A JOY 12CM-11 CONTINUOUS MINER. HE WITHOUT TELLING ANYONE OF HIS WHEREABOUTS ATTEMPTS TO SPOT SOME BITS AND IN THE PROCESS OF ALI GNING THE PIVOT PIN, THE CONVEYOR PAN CAUGHT HIS RIGHT FOOT.
1993 · 2 incidentes
LOW COVER ARE THE AREA HAD BEEN BOLTED WITH 4 TO 6 FT RESIN BOLTS ON A STAGGERED PATTERN. CRIBS WERE BUILT WITH 8X8X16 HEADERS ACROSS SPAN OF 12 FT ROADWAY RODE ALL CRIBS AND HEADER EXCEPT ONE SET AREA NOW CRIBBED OFF 50000 CFM OF AIR MEASURED ON OUTBY SIDE OF FALL. FALL WAS REPORTED AND INSPECTED TIMELY.