EE was cutting a piece of belt for the jaw feeder. EE was holding the rubber with left hand and cutting with the right. While cutting, the utility knife slipped and struck the EE on the left inside forearm. EE was cutting towards self. EE sustained a laceration that required 5 stitches. EE continues to work and did not miss any days of work.
7912 Bit Split Plant Metal/Non-Metal
Seguir esta mina
Avísenme cuando se presente un nuevo incidente de la MSHA en 7912 Bit Split Plant.
- Muertes
- 0
- Incidentes totales
- 9
- Años en registro
- 2000–2022
- Último incidente
- Jul 2022
| Trimestre | Horas trabajadas | Citaciones | S&S | Por 1M hrs |
|---|---|---|---|---|
| 2025 Q4 | 2,498 | 0 | 0 | 0.0 |
| 2025 Q3 | 3,097 | 0 | 0 | 0.0 |
| 2025 Q1 | 1 | 0 | 0 | 0.0 |
| 2024 Q4 | 1,918 | 0 | 0 | 0.0 |
| 2024 Q3 | 3,225 | 0 | 0 | 0.0 |
| 2024 Q2 | 3,422 | 0 | 0 | 0.0 |
| 2024 Q1 | 151 | 0 | 0 | 0.0 |
| 2023 Q4 | 1,619 | 0 | 0 | 0.0 |
Incidentes reportables
9 en archivo2022 · 1 incidente
2021 · 1 incidente
EE was trying to remove a large piece of metal from the conveyor magnet. Typical pieces were not this large. The EE used a crowbar to open a gap between the metal and the magnet. When trying to pry the piece off with a shovel, the shovel slipped causing the metal plate to snap back to the magnet, crushing the EE's left thumb.
2018 · 1 incidente
EE was removing the bucket from the skid steer. EE had the bucket lifted off the ground. When ee got it unhooked the bucket came off and landed on feet.
2014 · 1 incidente
Annual hearing test results indicated an average change of hearing in the left ear of 12.6 dB and a change of 14.3 dB in the right ear.
2009 · 1 incidente
Employee was testing wiring in the electrical panel of generator 7633, an arc flash occurred sending a "ball of fire" out of the panel. The fire caused burns to the top of both the employee's hands.
2008 · 1 incidente
EE was standing on the belt guard trying to loosen a mantle nut on the main frame. He had both feet on belt guard. He went to step off onto the lower platform and slipped. He tried to catch himself on the guard rail but missed striking his upper right side rib cage on the adjusting bolt on the main frame of unit.
2007 · 1 incidente
While torching metal an amber flicked into his boot causing a 3rd degree burn to his left foot.
2006 · 1 incidente
Loader step was covered in snow. Employee slipped while exiting the loader. Diagnosis is first degree right ankle sprain. Able to return to work immediately. Told to take Motrin and wear boots that supported the ankle.
2000 · 1 incidente
END OF RIGHT FOOT UNDER LOADER BUCKET WHEN LOWERED. FRACTURED BIG TOE ON RIGHT FOOT.