EE STATED THAT WHILE BOLTING THE MINE ROOF HE INJURED HIS SHOULDERS, NECK AND BACK. (HE WAS INJURED ON 1/10/01 BUT CONTINUED TO WORK UNTIL A DOCTOR VISIT ON 2/14/01. BEGAN MISSING WORK ON 2/1 5/01.)
Deep Mine No 3 Coal
Seguir esta mina
Avísenme cuando se presente un nuevo incidente de la MSHA en Deep Mine No 3.
- Muertes
- 0
- Incidentes totales
- 5
- Años en registro
- 2000–2001
- Último incidente
- Jan 2001
| Trimestre | Horas trabajadas | Citaciones | S&S | Por 1M hrs |
|---|---|---|---|---|
| 2002 Q2 | 0 | 0 | 0 | |
| 2002 Q1 | 0 | 0 | 0 | |
| 2001 Q3 | 0 | 0 | 0 | |
| 2001 Q2 | 0 | 2 | 0 | |
| 2001 Q1 | 24,120 | 2 | 1 | 82.9 |
| 2000 Q4 | 24,687 | 5 | 3 | 202.5 |
| 2000 Q3 | 24,877 | 3 | 2 | 120.6 |
| 2000 Q2 | 25,459 | 1 | 0 | 39.3 |
Incidentes reportables
5 en archivo2001 · 1 incidente
2000 · 4 incidentes
AN UNINTENTIONAL ROOF FALL OCCURRED OUTBY MMU0020 SECTION INTHE INTAKE AIRWAY. THE FALL MEASURED20'L, 20'W & 4'TO 6' HIGH
AN UNINTENTIONAL ROOF FALL FELL FROM THE NO.1 ENTRY TO THE NO.7 ENTRY OUTBY MMU 002-0, TWO BREAKS INBY EP 1. THE FALL WAS 20' LONG, 20' WIDE AND 4' TO 6' HIGH.
AN UNINTENTIONAL ROOF FALL OCCURRED IN THE NO. 3 ENTRY OUT BY MMU-002-0 SECTION. THE FALL MEASURED 70' 10" LONG, 19' WIDE AND 4' THICK.
AN AWARD FOR AND A DIAGNOSIS OF OCCUPATIONAL PNEMOCONIOSIS WAS MADE. OPERATOR NOTIFIED ON 1/24/2000.