The miner operator stopped mining, swung the tail toward the right rib and exited the cab. It is unclear why EE exited the cab of the miner. EE was a couple feet from the operator's compartment when the arch fell, striking EE in the head/neck/shoulder/upper back area. The injured employee was provided first aid in the mine and taken to the Memorial Hospital of Sweetwater County.
Buscar en el registro
Cada lesión y muerte que la MSHA tiene registrada. Filtra por estado, año, sector, clasificación, experiencia o cualquier palabra clave de la narrativa del investigador.
- Incidentes totales
- 273,095
- De los cuales mortales
- 1,202
- Años en el registro
- 2000–2026
- Clasificaciones
- 20
Notifícame sobre esta búsqueda
Envíame un correo cuando un nuevo incidente coincida con estos filtros. Un correo de confirmación; cancela la suscripción cuando quieras.
393 registros coincidentes
Mostrando 50 de 393Performing an inspection inside of a tank, coming out of the tank from the side opening, feet first and had pressure to EE's biceps pulling self through the opening, lost grip with EE's right hand, used EE's left hand and arm to catch self and immediately felt pain and burning sensation in EE's left bicep.
An EE was jack hammering the Debris when it broke free. IE's hand was on the stack wall when the debris impacted EE's fingers
Removed a counter weight guide rail on a bucket elevator to work on a bearing behind it and when re-installing it, the lower portion slid off of the base and started to fall downward. As it fell, the injured employee grabbed the rail so it would not fall towards EE. This resulted in EE's left index finger being pinched between a stop block and the counter weight frame.
Assisting with a horizontal pressure leaf filter, being filled with hot water, in preparation for an acid wash, on the deck to confirm when the filter was full. The carriage bolt assembly that holds the filter head, to the filter shell, failed and sprayed the employee with hot water. Employee was treated for 1st and 2nd degree burns and given a full work release on 08/02/21.
An employee was walking and stepped on a rock and rolled right ankle but continued working through the shift. Medical treatment was sought and an MRI was obtained on July 20th which determined that they had ligament issues in the ankle then employee was placed on restricted duty July 22nd.
Engineer was climbing the steps on a locomotive when hips and back began to hurt. Later claimed to have numbness in hands and legs.
Employee struck head on a roof support cable bolt. The suspension in EE's hard hat broke and EE received a laceration, to the scalp, likely from the rivet for the suspension.
Track laborer was using a track wrench on a joint bar bolt. EE slipped and twisted left ankle.
Employee was adjusting fly ash system when a piece of material blew into EE's eye. EE was checked by a physician and received a prescription antibiotic ointment for precautionary purposes. This injury report was overlooked during furloughs, etc. amidst the COVID crisis.
Installing a monkey face with a hilti drill and pinched EE's finger between the roof and the monkey face causing a laceration that required sutures to close.
Employee was getting on the manlift. EE's foot got caught/snagged on the landing floor as EE was stepping while the lift lowered. As EE was shutting down the lift, EE's knee twisted. As a result, EE injured the knee which has required modified duty and physical therapy as of 4/28/20.
A bore miner was parked in an area under roof support to replace a shear pin. The roof was checked visually and appeared to be in good condition. A 5"x10"x1-3" thick piece of the roof, in front of the bore miner and inby roof bolts, separated, broke apart and fell. A piece of the material hinged, swung toward the miner, and hit EE.
Employee was onsite doing drilling and suffered a nonfatal heart attack. Medical treatment was started and employee was transported to the hospital.
Employee was installing roof bolts. The steel plugged, the employee struck the steel with the drill wrench. Upon striking the steel, the socket end of the wrench broke causing the socket to ricochet off the mast and struck the employee in the thumb.
Employee notified management about soreness in elbow in March, EE is a surface mechanic and continued to work until September when EE notified us that the elbow was sore following work on a screw conveyor. EE had an MRI which indicated mild triceps tendinosis. EE was prescribed physical therapy making this reportable.
Team member was lining a rail switch when team member felt a pop in left chest/rib area. Team member continued to work and finished shift. On 8/5/2019 team member went to a doctor where xrays were performed and a steroid was prescribed to help with swelling. No lost time, no work restrictions were placed.
While hanging bolter cable, a piece of shale dislodged and hit the employee
A mechanic's hand was injured by a fan sheave and pinched by the V-belt mechanism resulting in a laceration and a fracture of the hand.
An employee was struck by a shard of metal while replacing the bits on the bore miner.
Employee was attempting to unroll a tape wrap on an extension cord bundle. The employee removed gloves to unroll the tape. After failing to unroll the tape the employee pulled out personal pocket knife in an attempt to cut the tape. During cutting a cut occured to EE's left hand between the thumb and index finger.
NAIS crew was hydroblast cleaning the inside of tank. EE wanted to shotgun a different area of the tank but there was a slab of material approx. 30-40 lbs where EE wanted to stand. EE tried to pick up the material to move it out of the way. EE lost control of grip and the material fell on EE's right hand. EE was able to get hand out from underneath the material and exited the tank.
The injured person was using pliers to pull zip ties to secure electrical wiring. The pliers slipped off the zip tie and hit the employee in the mouth breaking a tooth and chipping another tooth. The injured employee return to work the next scheduled shift and has not lost any time for the incident.
A piece of a cone shaped plate was being lifted into place. The plate started to tip over and the supervisor said to let it fall because it was still attached to the chain fall. While the supervisor was talking, EE reached out to grab the chain and cut left middle finger on top of the plate. EE had not yet put gloves on.
A mine crew was welding sections of Drisco pipe together for use by Mine Tailings. In the process of aligning two sections of pipe in the welding machine assembly, the employee's hand was pinched between the sections of pipe. This resulted in a non-displaced fracture to the first knuckle joint of the right index finger.
Team member received a papercut to their right index finger on 7-5-18. Washed the cut out with soap and water and put latex glove over it. 7-12-18 Team member went to dr for antibiotics for infection to the papercut. 7-17-18 EE was taken to hospital for care and to prevent septic shock.
A mine production ee was changing miner bits. During the removal process a bit became stuck and as the ee pulled addition force to free the bit, the bit wrench slipped causing the bit wrench handle to strike another bit, pinching the ee finger between the bit wrench handle and a miner bit, resulting in a fracture to the ee right index finger.
Employee was hauling a load of roof bolts and resin to a production panel. The bolting resin stack had worked out of position in transit. The employee attempted to manually re-adjust the bolting resin, as ee was pushing the resin back into the proper position, ee felt a "pop" and discomfort in lower right leg. EE was placed on restricted duty beginning 4/11/18.
Worker was repairing a conveyor belt. The worker was cutting the belt close to an area where there was a mechanical splice in the belt. The knife blade caught on the mechanical splice, the worker lost control of the knife blade and sustained a laceration to EE's right knee. Medical treatment in the form of 4 Stitches was required. The worker was released to return to work.
A Mine Production crew was repositioning trim chain onto a sprocket, trying to rotate it by striking it with a hammer, so employee was kneeling in front. A fragment of metal separated from the sprocket and struck the employee in the upper leg. An attempt to retrieve it was done on 2/21;ee received two stitches and was placed on restriction to allow the injury to heal.
EE was walking between the A track and Runner switch at the Landing at Solvay when EE slipped on a piece of ice falling on buttocks. EE felt a pain in lower neck/mid back area and a tingling in left hand. EE was taken to the ER where EE was advised a follow up with EE's primary physician, restricted to light duty and discharged.
An employee using a metal hammer, connecting a pin into the links on a conveyor chain sustained a puncture wound that was caused by a piece of metal that had come from the pin as it was struck by the hammer, in EE's thigh. After, EE became aware of this, a few days later, EE was taken for medical evaluation where it was determined that the metal fragment should be removed.
A Mine employee was positioning a relay bar being installed on the longwall set-up face and supported by a come along (chain style). While positioning the relay bar, the come along chain broke and struck the employee in the face. The employee sustained a laceration wound on the chin that required stitches and a tooth was also damaged. The employee has been released to work.
Incorrect components in the VF Drive led to overheating of a transformer and a normally open contractor. Overheating of contractor led to the welding of the internal contacts, resulting in abnormal current flow to area where incident occurred.
A hoist mechanic removing a check valve nut using a 4lb hammer and a pin hammer, when ee felt a pull in arm. The employee was treated on site, before being taken to the local hospital, and was released back to work pending further evaluation. Upon medical recommendation on October 26, 2017, employee elected surgery, scheduled for October 30, 2017.
An employee was setting up the first piece of decking on a new overcast. As the crew set the side walls, the first piece of decking rotated and struck the employee. Their left little finger was pinched between the decking and floor. The employee was treated on site, taken to the local hospital, and the wound required stitches to close. The employee was released back to work.
A Mine Maintenance employee, that was wearing cut resistant gloves, was repositioning a sprocket the employee was welding. In the process of moving the part, finger was pinched between the sprocket and another tool. The employee was treated on site before being taken to the local hospital where the wound was closed with twelve stitches. The employee was released back to work.
An employee received a laceration while tightening a bolt with a hammer wrench that slipped, pinching employee's finger between the wrench and breather pipe cap. The employee was treated on site before being taken to the local hospital where the wound was closed with seven stitches. The employee was released back to work without restriction.
Individual was tightening a T hand on an iron hand attached to a forklift with a wrench. The wrench slipped causing the individual to strike hand on the forklift causing a laceration.
While removing a valve, a mechanic accidentally bumped a 24 inch pry bar, which fell through a grating opening, striking the pipe below, then falling at an angle, striking an employee working approximately 15' to the side of the overhead work, resulting in a non-displaced curvilinear fracture of the scapula.
An employee returned to the Steamplant Control Room to collect paperwork for employee's next job task. The employee went to the kitchen area to get a drink where employee collapsed. Aid was rendered immediately and on-site emergency personnel were summoned. Employee was transferred to the local hospital unfortunately all efforts failed to save employee's life.
A roof bolt operator fell, striking head, resulting in a laceration.
Employee was cleaning snow out of A switch in the Solvay landing rail yard & stepped in between the bridle rod and felt knee hyperextend and immediately felt swelling. Employee informed supervisor of the incident at approx. 12pm the same day.
Removing a table and vice from a drill platform. Removing the top T bolt and was starting to remove the bottom T bolt, when the vice rotated and pinched the employee's finger between the vice and the bolt. Requiring nine stitches to close the wound to the tip of right middle finger. An x-ray showed no fracture. The employee was released on restricted duty.
The employee was performing a visual inspection of the area; walked to the back of the mining machine to un-hook the water hose and retrieve the remote for the continuous haulage. As ee was walking back to the bolter station, a roof slab fell hitting the mining machine, the load out tail of the miner and the employee.
Working to connect piping in mine, EE used EE's shoulder to support the pipe while lowering the pipe hanger. Felt a pop in EE's right shoulder. Reported on 9/11/16, taken to be evaluated and given a full release on 9/13/16. 9/15/16, the employee requested an MRI and was given a second full release. 10/6/16 the employee was seen by the company doctor and placed on restricted duty.
Working in an area with accumulations of crystal & hot liquor, felt a sharp pain in left heel, exited the area and found a small blister because of a tear in the back of rubber boots. The burn was minor and EE worked the rest of the shift, next shift and went on scheduled days off. On 9/16 the total area had grown in size, went to the doctor and was placed on restricted duty.
An employee was operating the #6 BMR when a rock approximately 2 inches in diameter released from the mining face and deflected off the cutting arm striking the employee in the mouth. The impact caused a chip to the employee's tooth and a scratch to their lip. The employee was treated and released to full duty.
The employee was adding 25' of vent tube to a high velocity fan when dust was dislodged from the tube which was blown into eye from the side around safety glasses. Employee's eye continued to be irritated so employee notified supervisor on 8/25/2016 and was seen by an Optometrist. Employee was diagnosed with an eye infection and given antibiotic drops.
A Mine Utility crew was moving a shuttle car with a Wagner loader, attached with a chain. Two - 8 ½" hydraulic hoses were hooked up for the steering of the shuttle car. The chain became un-hooked, which tensioned the hydraulic hoses, until they broke. A hydraulic hose whipped back towards the operator of the Wagner striking EE in the chest & neck. EE received three stitches.