Electrician was changing the bearing on the #1 taipiece. When he went to grab the shaft a piece of metal went through his glove and stuck in his right index finger. When he removed it some was left in the wound. The metal was removed by the Dr. and (5) sutures were required. This is to report medical treatment only. No days were lost.
Buscar en el registro
Cada lesión y muerte que la MSHA tiene registrada. Filtra por estado, año, sector, clasificación, experiencia o cualquier palabra clave de la narrativa del investigador.
- Incidentes totales
- 273,095
- De los cuales mortales
- 1,202
- Años en el registro
- 2000–2026
- Clasificaciones
- 20
Notifícame sobre esta búsqueda
Envíame un correo cuando un nuevo incidente coincida con estos filtros. Un correo de confirmación; cancela la suscripción cuando quieras.
350 registros en total
Mostrando 50 de 350Unintentional roof fall 50' long x 20' wide x 3' to 5' in thickness. The fall is located on 8 left panel #14 crosscut and #8 entry.
Employee was shoveling the #4 belt drive in a stooped position and when he stood up his back started hurting and left leg went numb.
Employee was bolting top, putting in a rib bolt when the swing level got fouled and pushed him into the rib causing bruising.
turned 992 loader over into a pit. He was a contractor for Bates Contracting & Construction Inc. They reported the accident to MSHA. I got a violation issued on 7-9-09 to file an accident report on incident also.
An accumulation of methane was found from out gassing seals in a small isolated area. We consider this a non-inundation incident.
Was cutting wire tie off of a mirror with a razor knife and cut left middle finger requiring 5 stitches.
Employee began missing work because of surgery to his right knee.
As afternoon crew arrived on 02 section, they discovered a roof fall in #1 Entry inby loading point. Area was cribbed, timbered and dangered off. Area was investigated by State & Federal. 2 blks inby Spad 5836.
A fall has occurred 30' inby survey spad 1787 in the #1 entry of the No. 2 Southwest mains. Fall is approx 50' long X 20' wide X 5' high. Area has been timbered and dangered off. No affect to ventilation.
Employee began missing work this day because of a twisted back he suffered exiting a scoop. MRI indicated degenerative change and chronic no clinical.
This is to comply with violation #8075775 at the Josephine #3 Tunnel Mine. On 3/15/09 EE, 3rd shift Fire Boss, found loose rashy material had fallen from the highwall on the inby side of the fan house. The material measured approx. 9'H X 4'-6'L X 9'W.
Unintentional roof fall was found while making rounds inby spad 2580, approx 4 X-cut.
Employee using right side handrail to pull up on truck, pulled muscle in right upper arm.
Employee was loading a SC in the face when a brow rolled off and hit him in the right shoulder. Due to complications he had an operation on his shoulder on May 15, 2009 and is missing work.
Employee was putting a feeder flight in the feeder when the flight struck his left ring finger. He suffered a fracture to this finger.
Hit roof bolt that was hanging down with left ear requiring 6 stitches.
Employee was working off of a ladder and his boots were muddy causing him to lose traction and slip. He fell off of the ladder and landed on his elbow resulting in two fractured bones.
Victim was checking blower motor belt on bolt machine and operator started machine and pulley caught rt thumb and cut it, requiring stitches.
Employee was trimming a belt splice, when the knife slipped and hit him on the inside of the left knee, causing a laceration that took 6 sutures to close.
Walking to mine office, slipped and fell on ice.
A rock fall was found at crosscut #45 blocking the primary escapeway (#7 entry) by the pre-shift foreman. The fall is approximately 35' long X 5' high X 20' wide.
Employee was working on a V-scraper when he cut his hand. Stitches were required when treating the cut.
Employee was riding bus (mantrip) and when it approached his piece of equipment he stood up as the bus operator braked and he fell and stuck his head on the header above the windshield. He was diagnoised with a cervical strain and concussion.
Employee was exiting a 930 loader, when he lost his footing and fell off of the steps to the ground, landing on his right knee and bending it back under his body.
Employee complained of his back hurting on 1-7-09 and started missing work on 1-14-09. Doctor's report shows that the employee is suffering from degenerative facet disease.
Employee was changing bits on a miner head when a rock slid out about 3 or 4 feet and struck his right hand and cut his pinky finger.
An unmapped mine was cut into while mining was being performed on the 001-0 MMU. A small amount of water was released into the active section. No Methane or low Oxygen was released from the old works and no hazards were noted. All Persons were withdrawn and production was immediately stopped.
Employee was using a utility knife to cut open a splice in a shuttle car cable when the knife slipped and cut his middle and ring fingers of his left hand causing lacerations that required approximately 8 stitches to close.
A roof fall was discovered by airway examiner on C1 panel in old worked out area. The fall was at #3 left entry spad # 2227 in 4 way intersection. Area has been timbered off. The fall was 25' wide X 40' long X 6' high. It was found at 11:15 pm on 12/18/08.
Employee was in the process of changing rollers on the stacker belt when he caught his right hand between a roller and the belt rail causing a fracture to his right ring finger.
Employee was cleaning scrubber on miner when he received a laceration on his head that required stitches.
A piece of rock fell against the bolter head as employee was bolting. He was moving the piece of rock when his lower back popped. Employee finished his shift of work and started missing the following day (12-3-08).
The injury was not reported until 11/23/08. We were informed that the EE was grinding metal and got something in his eye at that time.
EE was pulling belt with channel locks and changed locks, slipped and EE fell into rib and hurt right shoulder. EE had to have surgery on 12/8/08. Returned to work on light duty 12/9/08.
Employee was using a pry bar and mashed the right middle finger. The wound required stitches.
Employee was struck by ram car and suffered a laceration that required stitches.
Using a utility knife and while trimming a piece of belt, he cut his left forearm. Treatment required stitches.
EE was putting first aid box in scoop on power move and caught rough edge with right thumb.
Employee was pulling a jumper cable and injured his shoulder. It was dislocated and out of place. Dr repaired and he returned to work.
A rock fall appox. 20'x20'x6' high fell in the break between # 1 and 2 headings in the return near spad number 64. This fall does not impede the travel or air flow.
Employee was found slumped over a three wheel mantrip and he had suffered a heart attack.
Victim was cutting plastic band on bucket of plaster when utility knife slipped and cut right leg requiring staples to close the wound.
Employee was pulling on a water hose, when he slipped and fell, striking a three wheel mantrip with his jaw and knocked an upper rear tooth out.
Employee was lifting motor off base plate, when motor slipped and caught EE's finger. Required stiches to close wound.
Employee was tramming the Miner away from the rib to service it when he got caught between the deck and rib.
While removing lid employee caught fingers underneath lid and had minor surgery of finger that required stitches.
Employee was operating a three wheel mantrip going down a slope, when he steered to make a turn the three wheeler turned over causing injury to his shoulder and neck. Due to complications he started missing work on February 05,2009.
While removing lid from miner, lid slipped and caught fingers, breaking ring finger and cutting little finger.
While traveling airways a roof fall was identified in the old Mains Section at break #62 in the #1 entry near spad #358. The fall extended right handed into the crosscut and measured approx. 20'L X 25'W X 6'H. The area was supported with 5' torque tension and 12' supplemental supports. The area has been dangered off and timbers have been set.