CLAIMANT HAS BEEN GRANTED A 10% AWARD FOR OCCUPATIONAL PNEUMOCONIOSIS. THIS TOOK PLACE ON THE ABOVE SPECIFIED DAY. (12/4/01)
En todo el registro
- Incidentes totales
- 740,335
- De los cuales mortales
- 3,118
- Años en el registro
- 1983–2026
- Clasificaciones
- 20
Notifícame sobre esta búsqueda
Envíame un correo cuando un nuevo incidente coincida con estos filtros. Un correo de confirmación; cancela la suscripción cuando quieras.
68 registros en total
Mostrando 50 de 68ON 2/26/02, EMPLOYEE RECEIVED AN AWARD FOR OCCUPATIONAL PNEUMOCONIOSIS OF 15%.
EE WAS OPERATING A 488 SCOOP IN THE NO. 5 HEADING WHEN THE OFFSIDE OF SCOOP CAUGHT A POWER CORD GOING TO A FLUORESCENT LIGHT. THE LIGHT STRUCK THE OPERATOR OVER THE LEFT EYE. HE WAS TRANSPORTE D TO HOSPITAL WHERE SUTURES WERE REQUIRED TO CLOSE THE WOUND.
EE WAS HOLDING COUPLER OF SUPPLY CAR TO ALIGN IT UP WITH COUPLER OF MOTOR. FINGER WAS CAUGHT BETWEEN COUPLER WHEN MOTOR MOVED FORWARD.
AN UNPLANNED ROOF FALL HAS OCCURED IN THE #2 ENTRY (RETURN) 100 FT FROM THE ACTIVE WORKING FACE. THE FALL MEASURED 70' X 16' X 36". THIS AREA WILL BE REHABILATATED/
EE WAS OPERATING MINER IN #3 RIGHT CROSS CUT WHEN A PIECE OF DRAW ROCK APPROX (3'X6'X1"-4") FELL FROM BETWEEN THE RIB BOLT & COAL RIB STRIKING HIM ON THE RIGHT FOOT. HE WAS POSITIONED TWO ROWS BACK FROM THE OUTBY CORNER OF THE BREAK. HE WAS TRANSPORTED TO HOSPITAL WHERE X-RAYS REVEALED A FRACTURE OF THE METATARSAL BONES IN R FOOT. HE WAS WEARING METATARSAL BOOTS AT TIME OF ACCIDENT
A ROOF FALL HAS OCCURRED IN THE RETURN ENTRY, APPROX. 11000 FEET FROM THE ACTIVE SECTION. THE FALL MEASURED 60'LX20'WX40"THICK. ALL ENTRANCES TO THE ROOF FALL HAVE BEEN BREAKERED OFF.
EMPLOYEE WAS OPERATING A ROOF BOLTER INSTALLING BOLTS. HE GOT HIS HAND CAUGHT BETWEEN BOLTER HEAD BOOM AND JACK.
EE WAS OPERATING A ROOF BOLTER WHEN THE ACCIDENT OCCURRED. HE WAS INSERTING A GLUE STICK INTO A DRILL HOLE WHEN A PIECE OF DRAW ROCK FELL, STRIKING HIM ON HIS RIGHT ARM. THIS RESULTED IN A LAC ERATION. SUTURES WERE USED TO CLOSE THE WOUND.
A ROOF FALL HAS OCCURRED IN THE #5 ENTRY,5 BREAKS OUTBY THE FACE NEAR STATION SPAD #6295. THE ROOF FALL MEASURED 6" HIGH X 20' LONGX 30' WIDE. 42 INCH RESIN BOLTS WERE USED IN THE AREA. THIS F ALL WILL NOT BE CLEANED UP AND RESUPPORTED. THE SECTION HAS BEEN MOVED TOANPOTHER AREA OF THE MINE.
A ROOF FALL OCCURRED IN THE #8 HEADING AT STATION SPAD #6303,TWO BREAKS OUTBY THE FACE. THE FALL MEASURED 6'HIGH X 25'LONG X 19' WIDE. THE AREA AROUND THE ROOF FALL HAS BEEN TIMBERED AND THE S ECTION HAS BEEN MOVED TO ANOTHER AREA OF THE MINE.
A ROOF FALL WAS DISCOVERED IN THE #4 ENTRY,2 BREAKS INBY SPAD NO. 5280. THE ROOF FALL WAS APPROXIMATELY 50'LONG X 20' WIDE X 6' HIGH. THE AREA AROUND THE ROOF FALL HAS BEEN TIMBERED.
EE AND A COWORKER WERE SPLICING A TRAILING CABLE FOR A SHUTTLE CAR. THE EE WAS USING A POCKET KNIFE TO CUT THE INSULATION ON THE CABLE; THE BLAD SLIPPED AND LACERATED THE EE'S LEFT RING FINGER . SUTURES WERE REQUIRED TO CLOSE THE WOUND. THE EE RETURNED TO WORK FOLLOWING MEDICAL TREATMENT. NO LOST WORKDAYS--MEDICAL TREATMENT ONLY (HAND TOOLS. EE NOT WEARING GLOVES.
EE WAS TRANSPORTING BELT TOOLS ON THE SECTION WHILE OPERATING A TRACKMOUNTED PERSONNEL CARRIER WHILE TRAMMING UP THE TRACK AT THE #25 CROSSCUT A PIECE OF DRAW ROCK FELL FROM THE ROOF & STRUCK THE EE ON THE FACE, RIGHT UPPER ARM AND RIGHT LEG. THE DRAW ROCK MEASURED 1" TO 31/2" THICK BY 32"LX24"W. EE WAS TRANSPORTED TO WILLIAMSON MEMORIAL HOSP. SUTURES WERE REQUIRED TO CLOSE A
AN UNPLANNED FALL OF ROOF OCCURRED AT APPROX. 10:45 PM ON 5-19-97 IN THE #3 ENTRY, 1 CROSSCUT OUTBY STATION SPAD #5760 (APPROX. 400' OUTBY THE ACTIVE SECTION). THE FALL IS IN THE 2ND LEFT PANE L OFF THE ANGLE SUB-MAINS. THE FALL MEASURED 30' LONG BY 40' WIDE BY 5 1/2' THICK. THE AREA HAD BEEN SUPPORTED ON THE ADVANCE WITH 42" FULLY GROUTED RESIN BOLTS. NO EQUIPMENT DAMAGE OR INJURI
UNPLANNED ROOF FALL OCCURRED TWO CROSSCUTS INBY (SPAD #5735) AT 200' FROM FACE. FALL WAS APPROX 30'L, 40'W, 4'THICK. AREA HAD BEEN SUPPORTED ON THE ADVANCE WITH 42" FULLY GROUTED RESIN RODS. N O INJURIES. NO EQPT INVOLVED. AREA CRIBBED\DANG.
AN UNPLANNED FALL ROOF OCCURRED 13 CROSSCUTS OUTBY FEEDER 9 ENTRY 1 CROSSCUT OUTBY SPAD 5626. THE FALL WAS APPROX. 100' LONG BY 18' WIDE BY 5 TO 6' THICK. THE AREA HAD BEEN SUPPORTED WITH 42" FULLY GROUTED RESIN RODS. NO EQUIPMENT INVOLVED.NO INJURIES.
AN UNPLANNED FALL OF ROOF OCCURRED ON SECTION 2 ENTRY IN INTERSECTION 4 CROSSCUT OUTBY FACE 1 CROSSCUT INBY SPAD 5663. THE FALL WAS APPROX. 25' WIDE BY 35' LONG BY 4' THICK. THE AREA HAD BEEN SUPPORTED ON THE ADVANCE BY 42" FULLY GROUTED RESIN RODS. NO EQUIPMENT INVOLVED.
UNPLANNED FALL OF ROOF OCCURRED IN LEFT CROSSCUTOFF #8 ENTRY IN SW MAINS (4TH). FALL WAS APPROX 6'THICK, 20'W, 250'L. THERE WERE NO INJURIES ANDNO EQUIPMENT DAMAGE ASSOCIATED WITH THE FALL. AR EA HAD BEEN SUPPORTED ON THE ADVANCE WITH FULLY GROUTED RESIN RODS. SHALE (LAMINATED) ROOF IN AREA.
UNPLANNED FALL OF ROOF OCCURRED IN #5 ENTRY, ONECROSSCUT OUTBY SECTION BELT FEEDER. APPROX 250' OUTBY WORKING FACES ON WORKING SECTION. FALL WASAPPROX 5-7'THICK, 60'L, 20'W. AREA SUPPORTED ON ADVANCE BY FULLY GROUTED RESIN RODS. NO INJURIES. EQUIPMENT DAMAGE TO SECTION BELT LINE.
EMP AND 2 COWORKERS WERE SCATTERING 42" BELT STRUCTURE IN PREPARATION FOR BELT MOVE. EMP PULLED A PIECE OF TOP STRUCTURE OUT OF SCOOP BUCKET AND ANOTHER PIECE SLID OUT OF SCOOP BUCKET AND STRU CK HIM ON SIDE OF RIGHT FOOT. EMP WAS WEARING METATARSAL BOOTS. RESULTING INJURY WAS A LACERATION REQUIRING SUTURES. MEDICAL TREATMENT ONLY. NO LOST DAYS OF WORK.
UN UNPLANNED FALL OF ROOF OCCURED AT APPROX 6:45AM ON 11/6/96 IN THE #5 ENTRY (TRACK ENTRY) 7 CROSSCUTS INBY THE PORTAL. THE FALL WAS APPROX 60'L BY 19' W BY 3'-4' THICK. THE ROOF AREA IN THIS AREA WAS SUPPORTED ON THE ADVANCE BY 4' CONVENTIONAL ROOF BOLTS & WOODEN COLLARS. THERE WERE NO INJURIES AND NO EQUIPMENT DAMAGE. FALL WAS NOT WITNESSED
EE WAS DUMPING A LOAD OF COAL AT THE FEEDER. THE OPERATOR HELD HIS HAND IN FRONT OF THE COAL DEFLECTOR INSIDE THE CANOPY WHEN A PIECE OF ROCK CAUGHT HIS RIGHT HAND AND PUSHED IT AGAINST THE IN SIDE OF THE CANOPY. THIS RESULTED IN A LACERATION TO THE SMALL FINGER OF THE RIGHT HAND. THE ACCIDENT OCCURRED AT SPAD 4564 AT THE FEEDER. ACCIDENT DEGREE 6- NO LOST TIME.
EMPLOYEE WAS OPERATING A BATTERY POWERED PERSONNEL CARRIER WHEN A PIECE OF FLAT STEEL (1" X 6" X 3 FT. LONG) FELL AND STRUCK EMPLOYEE ON THE LEFT FOREARM, RESULTING IN A LACERATION. THREE SUTU RES WERE REQUIRED TO CLOSE THE WOUND. EMPLOYEE DID NOT MISS ANY WORK OR EXPERIENCE RESTRICTED WORK ACTIVITY. MEDICAL TREATMENT ONLY. (DEGREE 6 CLASSIFICATION 12).
UNPLANNED ROOF FALL OCCURRED ON 10-21-95. THE ROOF FALL WAS LOCATED IN #7 ENTRY. THE FALL MEASURED 100'L X 20'W X 60" THICK. IT WAS DANGERED OFFLOCATION BEGINNING AT SPAD #4111 AND CONTINUED O UTBY FOR 100'. NO INJURIES.
AN UNPLANNED ROOF FALL OCCURRED ON 10-4-95. THE ROOF FALL WAS IN #4 ENTRY. THE FALL MEASURED 30'LONG BY 20' WIDE BY 48' THICK. IT WAS DANGERED OFF. LOCATION 10' INBY STATION SPAD #4062.
AN UNPLANNED ROOF FALL OCCURRED ON 10-4-95. THE ROOF FALL WAS IN 4 ENTRY. THE FALL MEASURED 30' LONG BY 20' WIDE BY 48" THICK. IT WAS DANGERED OFF. LOCATION 10' INBY STATION SPAD 4062.
AN UNPLANNED ROOF FALL OCCURRED IN THE #8 ENTRY (RIGHT TURN) AT APPROXIMATELY 2:00 PM. THE FALL OCCURRED IN AN INTERSECTION TWO CROSSCUTS OUTBY STATION SPAD #3729. THE FALL MEASURED 20' BY 20' BY APPROX. 42" IN THICKNESS. THE ROOF IN THE AREA HAD BEEN SUPPORTED BY 42" FULLY GROUTED RESIN ROOF BOLTS ON THE ADVANCE.
EE WAS SHOVELING ON #2 BELT. THE BELT ROPE BROKE AND STRUCK HIM IN THE BACK.
EMPLOYEE AND 2 CO-WORKERS WERE USING CRIB BLOCKS TO PRY AGAINST A TRACK-MOUNTED, BATTERY POWERED PERSONNEL CARRIER. THE EMPLOYEE'S FINGER (MIDDLE-LEFT HAND) WAS CAUGHT BETWEEN THE CRIB BLOCK A ND THE MINE FLOOR RESULTING IN A FRACTURE OF THE END JOINT. THIS IS MEDICAL TREATMENT ONLY - NO LOST WORKDAYS OR RESTRICTED DUTY.
EMPLOYEE WAS ADVANCING UP TO NEXT ROW WITH A FLETCHER RR-II-13 ROOF BOLTING MACHINE, AS HE BEGAN TO BOLT, A PIECE OF DRAW ROCK FELL AND HIT TH ELEFT SHOULDER AND CENTER BACK OF OEPRATOR. THE DRAW ROCK MEASURED 40" LONG BY 42" WIDE ADN 3 DOWN TO 1 INCH IN THICKNESS.
HE WAS ATTEMPTING TO TAKE HIGHLINE OUT OF A SPLICE BOX WHEN HE RECEIVED AN ELECTRICAL SHOCK.
EE WAS APPLYING ROCK DUST A ALONG A BELT LINE. A S&S 488 SCOOP BUCKET STRUCK A 30" LONG CRIB BLOCK AND FLIPPED IT UPWARD. THE CRIB BLOCK STRUCK THE EE ON THE FOREHEAD AND RESULTED IN A LACERAT ION REQUIRING SUTURES. EE DID NOT MISS WORK OR HAVE RESTRICTED WORK ACTIVITY MEDICAL TREATMENT ONLY.
AN UNPLANNED FALL OF ROOF OCCURRED IN THE #5 ENTRY (#5BELT LINE) AT APPROX 5:00PM ON THE DATE SHOWN FALL WAS APPROX 4FT THICK BY 20FT WIDE BY 100FT LONG (APPROX 3 CROSSCUTS INBY STATION SPAD A#2745) THE AREA HAD BEEN SUPPORTED ON THE ADVANCE WITH 42IN FULLY GROUTED RESIN RODS NO INJURIES WERE ASSOCIATED WITH THIS ACCIDENT FALL WAS APPROX 4200FT OUTBY WORKING SECTION
EMPLOYEE WAS UTILIZING TWO PICK HAMMERS TO BREAK THE BAND ON A BUNDLE OF ROOF BOLTS. A SMALLS LIVER OF METAL CHIPPED OFF ONE OF HT EHAMMERS AND IMBEDDED IN THE EMPLOYEE'S RIGHT ARM. THIS INC IDENT DID NOT BECOME REPORTABLE UNTIL 10-29-94 WHEN THE EMPLOYEE'S INJURY REQUIRED SUTURES. EMPLOYEE DID NOT MSIS WORK AS A RESUTL OF THIS INJURY.
EE WAS PREPARING TO SECURE A CABLE ANCHOR FOR THE TRAILING CABLE OF THE SHUTTLE CAR. THE EE REPORTED THAT HE EXPERIENCED AN ELECTRICAL SHOCK WHEN HE PICKED UP THE CABLE ANCHOR TO SECURE IT TO THE ROOF. THIS EVEN DID NOT BECOME REPORTABLE UNTIL 10-20-94 WHEN THE EE BEGAN TO MISS WORK AS A RESULT OF HIS INJURY.
EMPLOYEE AND A CO-WORKER WERE OPERATING A TWIN-HEAD FLETCHER RR-II ROOF BOLTING MACHINE. EMPLOYEE SWUNG THE HEAD OF THE MACHINE TOWARDS HIMSELF AND THE HEAD STRUCK HIS LEFT KNEE PAD CAUSING H IS LEFT ANKLE TO CREEL. THIS RESULTED IN A FRACTURE OF A SMALL BONE IN THE EMPLOYEE'S LEFT ANKLE.
AN UNPLANNED ROOF FALL OCCURED IN THE LEFT RETURN AIRCOURSE 2 CROSSCUTS INBY STATION SPAD 1793. THERE WERE NO INJURIES AND NO MINING EQUIPMENT INVOLVEMENT.
EMPLOYEE WAS MOVING THE TRAILING CABLE FOR A FLETCHER RR-II-13 ROOF BOLTING MACHINE WHEN HE EXPERIENCED A PAIN IN HIS LOWER BACK HE CONTINUED TO WORK & DID NOT MISS UNTIL 08-27=94 (NOT REPORTA BLE UNTIL 08-27-94) THIS EVENT SHOULD BE CLASSIFIED AS A DEGREE 3 CLASSIFICATION 09 ACCIDENT THE MACHINERY WAS NOT MOVING AT TIME OF ACCIDENT
MULTIPLE ROOF FALLS WERE DISCOVERED IN THE MINE WHICH WAS IDLE #1 ENTRY FROM FACE TO APPROX 60FT OUTBY (5T THICK BY 18FT WIDE) #2 LEFT CROSSCUT 30FT LONG BY 5FT THICK BY 18FT WIDE #3 ENTRY 3 B REAKS OUTBY FACE IN INTERSECTION 30FT LONG BY 18FT WIDE BY 5FT HIGH & #4 ENTRY 6 BREAKS OUTBY FACE IN INTERSCTION 80FT LONG BY 18FT WIDE BY 5FT HGH (MEASUREMENTS APPROX) SHALE ROOF IN AREA
AN UNPLANNED ROOF FALL OCCURRED ON THE WORKING SECTION AT APPROX 10:00 AM ON 2/28/94. THE FALL OCCURRRD IN THE #4 ENTRY, 5 CROSSCUTS OUTBY THE FACES. THE FALL MEASURED 19' W X 60' L X 8' H. TH E ROOF IN THIS AREA WAS IN TRANSITION FROM SHALE TO SANDSTONE. THE PRIMARY ROOF SUPORT IN THE FALL AREA CONSISTED OF 48" FULLY GROUTED RESIN BOLTS.
EMPLOYEE SITTING NEAR MINER AND SAW A PIECE OF ROOF ROCK STARTING TO FALL. HE GOT UP AND RAN TOWARD THE INTERSECTION AND TWISTED HIS KNEE WHILE RUNNING.
ROOF FALL: #4 ENTRY (BELT ENTRY) AT SPAD 2021, 20' WIDE X 50' LONG X 42"-48" HIGH, 1500'-2000' FROM FACE WILL CLEAN UP BOLT.
ROOF FALL; 6 BREAKS INBY ENTRY IN MINE FAN. NO SPAD NUMBER 60' BY 20 ' BY 4' HIGH. CRIBBED AND DANGERED OFF. WILL USE OTHER RETURN.
INDIVIDUAL WA S GETTING MINER (CONT .) READY TO TRAM FROM 5 LEFT TO NO 6 HEADING WHEN A PIECE OF ROCK FELL FROM BETWEEN THE ROOF BOLT IT CUT HIS LEFT HAND AGAINST REMOTE BOX WHICH HE WAS CARRY ING
SETTING THE HOOD OVER CONVEYOR "A" DRIVE PULLEY. HAD HOOD ALMOST IN PLACE THEN SHOVED IT TO ALIGN HOLES. EDGE OF HOOD APPEARED TO BE RESTING ON DRIVE SHAFT. WHEN IT SLIDE OFF SHAFT HE HAD HIS FINGER UNDER FLANGE. (RIGHT MIDDLE FINGER) BROKE AND SMASHED ABOVE 1ST JOINT (FINGERTIP).
INDIVIDUAL WAS PULLING POWDER WAGON TO 1 HEADING TO SHOOT THE FACE PERSON IS SHOT FIRER AS HE WAS PULLING THE WAGON, A LUMP COAL WAS IN THE ROADWAY CAUSING THE WHEEL TO DISLODGE THE WAGON. T HE INDIVIDUAL JERKED THE WAGON OVER THE LUMP OF COAL INJURING HIS STOMACH.
DOCTOR'S STATEMENT ATTACHED.
ROOF FALL IN NO. 7 ENTRY. ONE BREAK ACROSS FROM SPAD NO. 1641. SIZE OF FALL 20'BY30'BY5' HIGH. USING 42' RESIN BOLTS. BARRACADED AND DANGERED OFF.
INDIVIDUAL WAS LIFTING CASE OF POWDER (APPROX 50 POUNDS) ONTO POWDER WAGON AND STRAINED HIS BACK.