EE was riding on the cx2 scoop being operated by other ee was cleaning #1 entry when he backed op and swivled the scoop. His foot got caught in the operators side of the center section. Crushing his foot causing a possible break to the bones in his foot.
Buscar en el registro
Cada lesión y muerte que la MSHA tiene registrada. Filtra por estado, año, sector, clasificación, experiencia o cualquier palabra clave de la narrativa del investigador.
- Incidentes totales
- 273,193
- De los cuales mortales
- 1,202
- Años en el registro
- 2000–2026
- Clasificaciones
- 20
Notifícame sobre esta búsqueda
Envíame un correo cuando un nuevo incidente coincida con estos filtros. Un correo de confirmación; cancela la suscripción cuando quieras.
69 registros en total
Mostrando 50 de 69WHILE INSTALLING STRAP WAITING FOR OTHER MAN TO SWING HIS BOOM, AS HE WAS HOLDING THE STRAP A PIECE OF SLICK SLATE FELL THROUGH OPENING IN HALO RING, HITTING EE ON THE RT. HAND. ROCK WAS 2'X 2' & 1 1/2"THICK. EE HAD A SMALL CUT & SWELLING ON LEFT SIDE OF HAND BEHIND THUMB.
Roof condition occurred in an area where several cracks were present. When a cut was taken out of the crosscut to the right it tied the cracks together in a triangle. The top started working in this area. A crib was built in the intersection. In time the laminated roof broke out around the crib.
EE BENT DOWN TO PICK UP A CRIB BLOCK AND PULLED A MUSCLE IN LOWER BACK
EE was tramming the miner across the section. He had stopped to hook a pull rope on boom of miner, when he accidently pinned himself between boom of miner & rib.
While tramming the miner, ee was struck in top of the head by a piece of draw rock. Rock measured approx. 10'L by 12" thick.
EMPLOYEE WAS BOLTING TOP. THE WRENCH SLIPPED OFF THE DRILL STEEL STRIKING HIM ON THE HAND.
Employee was bolting top when a loose piece of coal struck him in the eye.
EE WAS BOLTING TOP, DRILL POT WAS STOPPED UP. EE BENT DOWN TO UNSTOP DRILL POT WITH A PIECE OF WIRE WHEN A PIECE OF ROCK STRUCK HIM ON THE SIDE OF THE HEAD, CUTTING HIS HEAD.
EMPLOYEE HAD FINISHED BOLTING #7 ENTRY ON MAINS. AFTER BOLTING FACE HE BACKED OUT OF FACE ABOUT 30' FOR THE BOLTMAN ON OFF-SIDE TO SPOT A BOLT. EMPLOYEE WALKED AROUND TO OFF-SIDE OF BOLTER TO HELP OFF-SIDE BOLTMAN WHEN A LOOSE PIECE OF ROCK FELL FROM A SURFACE CRACK, STRIKING HIM ON THE LEG.
EMPLOYEE STRAINED HIS BACK LIFTING ON GEARS AT #2 BELT HEAD.
EMPLOYEE CUT HIS LEG WHILE USING A UTILITY KNIFE.
Area was on a point, roomed on 50' x 50' centers several cracks present. area bolted with 4' fully grouted bolts on 4' carters with straps. a wedge shaped piece of sandstone 16' long x 14' wide x 7' thick fell out on miner. fall will not be cleaned up except to move miner. section will be moved 700' outby.
EE had been making a belt splice. After completing splice and putting up his tools, ee slipped on slick mine bottom catching himself with his hands, stoving his pointer finger on left hand.
Fall is 20' x 20' x 5' thick, bolted with 4' & 6' fully grouted resin & roof straps. Area was cracked up bad on development and upon completion of mining the area was breakered off. Developed May 10th, 04. Fall is 800' from active section near spad 152. All areas are breakered off. Fall will not be moved.
Fall is 8' wide, 65' long, 5' thick, bolted with 4' resin and roof straps. Area cracked in several places on development 5-20-04. Fall near spad 174. Fall is breakered off and will not be moved.
EMPLOYEE WAS PREPARING TO INSTALL A ROOF STRAP WHEN A PIECE OF ROOF 25"X 25"X 3"THICK, FELL OUT BETWEEN BOLTS, STRIKING HIM ON THE HEAD.
EE WAS SHOVELING AROUND STACKER TAIL ROLLER, WHEN A LOOSE PIECE OF ROCK BOUNCED OFF BELT STRIKING EE ON THE LEFT SIDE OF THE FACE AND FOREHEAD.
Fall was found during a weekly exam of area. Area was developed 3-19-01 and is approx 6000' from face. Fall is 6' high by 40-45' long by 19' wide between #8 and #9 entry. Roof control plan was being followed and 6' glue bolts used.
INTERSECTION IN #4 ENTRY L.O.B.- THE FALL STARTED ON OUTBY CORNER AND FELL FOR ABOUT 35' INBY TOWARDS FACE AND BROKE OFF. TOP WAS SOLID WHEN BOLTED ON 2-14-04. NO WATER. FALL SHOWS SIGNS "NOW" OF WATER AND CRACKS WHERE FALL OCCURRED.
EE WAS SETTING UP SURVEY EQUIPMENT WHEN SLATE FELL FROM THE ROOF OF THE MINE.
WHILE WALKING TO BACK OF ROOF BOLTER TO GET SUPPLIES, EMPLOYEE WAS STRUCK ON THE HEAD BY A ROCK APPROXIMATELY 4' SQUARE. IT SLID DOWN HIS BODY, STOVING HIS NECK, SHOULDER AND BACK.
EE WAS BOLTING THE ROOF WHEN A PIECE OF ROCK FELL STRIKING HIM ON HIS LEFT ARM AND CUTTING IT IN 2 PLACES.
AN AREA OF ROOF 35'LONG - 8'HIGH FELL OUTBY SPAD 563 IN #5 ENTRY, NEUTRAL. THE ROOF IS SLATE, ROOF IS DRY, A RIDER COAL SEAM 8"THICK IS 8'ABOVE COAL SEAM. AREA WAS BOLTED WITH 4,6 & SOME 8' FULLY GROUTED BOLTS & SOME CRIBS. AREA WAS DEVELOPED 9/2001 & IS 1200'FROM SECTION. AREA HAS BEEN BREAKERED OFF. FALL WILL NOT BE MOVED.
A SECTION OF ROOF FELL IN THE #6 ENTRY NEUTRAL AT SPAD #710. FALL IS 30'LONG, 18'WIDE & 3-5'THICK. AREA DEVELOPED 12-01, BOLTED WITH 4'& 6'FULLY GROUTED RESIN. AREA IS 1500'FROM ACTIVE WORKIN GS. AREA IS SLICK SIDED SLATE. AREA WILL NOT BE REHABILITATED.
AN AREA OF ROOF FALL FELL IN THE #8 ENTRY INTAKE AT SPAD #803 (OUTBY) AREA WAS DEVELOPED IN 3-5-02. AREA WAS BOLTED WITH 4' X 6' FULLY GROUTED BOLTS. ROOF WAS WET LAMINATED SLATE. FALL IS 50' LONG, 18' WIDE, 3 TO 5 FT THICK. FALL WILL NOT BE MOVED. STOPPING LINE WILL BE MOVED OVER ESTABLISHING ESCAPEWAY.
AN AREA OF ROOF FALL ON #3 BELT AT BX#16. AREA BOLTED WITH 4&5 RESIN BOLTS. AREA IS SLICK-SIDEDSLATE. NO COAL RIDER SEAM PRESENT AREA IS DRY. DEVELOPED 5-25-01. AREA IS 6500FT FROM ACTIVE SECTION. FALL WILL BE MOVED, AREA HAS BEEN BRAKERED OFF FALL DID NOT EFFECT MOVEMENT OF MEN OR ESCAPEWAYS. (FALL IS 30' X 4' X 18')
AN INTERSECTION ON THE TRACK #5 ENTRY NEUTRAL AT #22 BREAK ON #4 BLET FELL. AREA WAS DEVELOPED ON 11-01 & WAS BOLTED WITH 4" & 6' FULLY GROUTED RESIN. FALL IS 20'X20'X 5' THICK. ROOF IS SLATE WITH A RIDER COAL SEAM AT 3'; ROOF IS DRY. FALL AREA WILL BE MOVED & REBOLTED. RIDER COAL SEAM IS 8" - 12" THICK.
AN INTERSECTION AT SPAD 836 #8 ENTRY INTAKE FELL. AREA WAS BELTED WITH 4'X 6'FULLY GROUTED BOLTS, AREA HAD MIXED ROOF, WATER IS PRESENT A 3"RIDER SEAM IS PRESENT AT 4'. FALL AREA SOFTENED UP & FELL OUT AROUND 6'BOLTS, PULLING THE 4'BOLTS OUT. AREA LATER FELL OUTBY FOR APPROX. 1 BK TO SPAD 826. FALL WILL NOT BE MOVED.
EMPLOYEE WAS GOING TO RAISE THE BATTERY LID ON A LOCOMOTIVE. THE LID WAS STUCK & WOULDN'T RAISE. HE STRAINED HIS LOWER BACK.
AN INTERSECTION AT THE NORTH OF #3 LEFT MAINS IN #7 ENTRY INTAKE FELL. AREA IS 20' X 20' X5' THICK. AREA DEVELOPED 2/02. SHALE ROOF, NO WATER, NO RIDER SEAM. BOLTED WITH 4' & 6' FULLY GROUTED BOLTS. AREA WAS BREAKERED OFF. AREA WILL BE REHABILITATED. MEN WERE MOVED OUTBY FALL AREA & WORK ON FALL HAS BEGUN. FALL AREA IS 1000' FROM SECTION FACE.
STACK ROCK STAND STONE ROOF, SEPERATED AND CRUMBLES ABOVE BOLT ANCHORAGE CAUSING FALL.
LOCATION OF FALL IS DIP AREA WITH ABOUT 5 FT OF SHALE ROOF CHANGING TO SANDSTONE, AREA WAS BOLTED WITH 4 FT ROOF BOLTS, SHALE PULLED AWAY FROM SANDSTONE CAUSING FALL.
STACK ROCK SANDSTONE ROOF WAS BOLTED BEFORE STAR PATLARM WAS PUT IN ROOF CONTROL PLAN AFTER THIS AREA WAS MINED, STACK ROCK SEPERATED ABOVE BOLT ANCHORAGE CAUSING FALL.
ROOF FALL INTERSECTION #8 ENTRY 002 SECTION APP 600' OUTBY FACE, STACK SHALE AND SAND STONE. APP 30'LONG, 20'WIDE, AND 8'THICK. SUPPORTED FROM MAIN ROOF. THIS IS A WET AREA UNDER FORK CREEK, F ALL WAS FOUND DURING WEEKLY EXAM OF RETURN AIR COURSE.
AREA FELL BETWEEN #2 & #3 ENTRIES RETURN, 3,000' FROM ACTIVE SECTION. AREA DEVELOPED 5-10-01. ROOF IS SLATE BOLTED WITH 4'& 6' RESIN. FELL RIB TO RIB, 3-4' THICK. THERE IS A 1 INCH RIDER ABOUT 2'-3' UP. FALL IS DIRECTLY ACROSS FROM SPAD 299. FALL WILL NOT BE MOVED.
AN INTERSECTION ON #3 BELT AT #40 BK FELL, SOMETIME OVER THE WEEKEND. FALL IS 1 BK INBY SPAD 468. AREA FELL RIB TO RIB, 4-5' THICK, AREA WAS BOLTED WITH 6' BOLTS. AREA WAS DEVELOPED 6-01. AREA IS BREAKERED & DANGERED OFF. ROOF IS SLATE, A RIDER SEAM IS PRESENT ON LEFT SIDE ONLY AT 4'. FALL WILL BE MOVED.
IN LOW LYING DIP AREA SHALE ROOF SEPERATED FROM SAND STONE AT APP 5 FT, AREA WAS ROOF BOLTED WITH 4 FT BOLTS, FALL WAS IN INTERSECTION AT SPAD H 1709. FALL WAS APP 5,800 FT OUTBY FACE OF H 1 S ECTION - SIZE OF FALL 30 FT LONG, 20 FT WIDE, 5 FT THICK.
IMMEDIATE ROOF WAS SHALE APP 5 FT THICK ADJOINING SAND STONE IN A LONG SWAG AREA BOLTED WITH 4 FT ROOF BOLTS SHALE PULLED LOOSE FROM SAND STONE.
A PIECE OF SLATE FELL OUT STRIKING THE OPERATOR IN THE NECK & SHOULDER AREA. IN A SUPPORTED AREA.
INJURED STATED HE WENT TO STEP OUT OF TRAILER WHEN HE SLIPPED AND FELL STRIKING HIS RIBS.
A SECTION OF ROOF 30' LONG X 6-8' THICK, RIB TO RIB, FELL, 2 BRKS OUTBY SPAD #787 IN #4 ENTRY MEUTRAL ABOUT 600' FROM SECTION. AREA WAS SUPPORTED WITH 6' FULLY GROUTED BOLTS. AREA WAS DEVELOPE D 2-8-02. ROOF WAS LAMINATED SHALE & SANDSTONE, NO WATER OR RIDER SEAM PRESENT.
EE WAS STANDING AT FRONT WHEEL OPERATORS SIDE WATCHING OTHER INSTALL LAST BOLT IN ROW. WHEN A SLAB WATCHING OTHER INSTALL LAST BOLT IN ROW. WHEN A SLAB OR LOOSE PIECE OF SLATE ROCK DISLODGED S TRIKING HE IN THE HEAD AND SHOULDER PIECE OF ROCK FELL FROM BETWEEN BOLTS.
A (SLIP) OR (HORSES BACK) FELL, 1 BREAK INBY SPAD 460. FALL WAS IN THE CROSSCUT THAT SPAD 469 WAS IN. FALL WAS APPROX 4'THICK, COVERING AN AREA 20' BY 20' OR INTERSECTION AREA.
ROOF FALL BREAK 41, 1 BREAK IN BY SPAD 296. FALL IS 20 FT BY 20 FT BY 4 FT THICK. AREA BOLTED WITH 4' BOLTS (RESIN FULL GROUT) AREA DEVELOPED 5-1-01 4,000 FT OUT BY FACE AREA. BREAKERED OFF FALL. FALL WAS FOUND 11-9-01 ON WEEKLY EXAMINATION.
EE WAS MOVING THE MINER, NOTICEING A PIECE OF LOOSE SLATE, EE STOPPED THE MINER, TOOK A SLATE BAR AND PULLED THE LOOSE SLATE, WHEN A PIECE OF THE SLATE STRUCK EE ON THE FOOT.
EMPLOYEE WAS SHOVELING BELT LINE AND AT AROUND #3 BELTHEAD WHILE SHOVELING EMPLOYEE'S HAND GOT CAUGHT IN BOTTOM ROLLER, BREAKING HIS HAND.
PUTTING UP A BOLT WITH 1/2 HEADER & BOLT STARTED TO BEND. VICTIM TRIED TO SPIN BOLT & 1/2 HEADER CAME AROUND AND STRUCK HIS RT WRIST.
EE HAD HIS HAND RESTING ON THE SIDE OF BOLTING MACHINE WHEN A PIECE OF SLATE FELL & HIT HIS HAND.
EE WAS BOLTING TOP AND A SMALL PIECE OF ROCK FELL AND HIT HIM ON SHOULDER. THE ROCK 2" THICK X 8" SQUARE. FELL FROM ABOUT 8' HIGH.