EE WAS FATALLY INJURED WHEN A METAL FRAGMENT FROM A PLANTARY DRIVE UNIT WAS STRUCK WITH A SLEDGE HAMMER THE METAL FRAGMENT ENTERED IN HIS LOWER RIGHT NECK CUTTING THE AORTA
Costain Group PLC: 20 muertes registradas controlador
Seguir este controlador
Avísenme cuando se presente un nuevo incidente de la MSHA en cualquier mina que controle Costain Group PLC.
Causas principales
- IGNITION OR EXPLOSION OF GAS OR DUST 11 muertes · 22 no mortales
- POWERED HAULAGE 4 muertes · 218 no mortales
- HANDTOOLS (NONPOWERED) 2 muertes · 198 no mortales
- ELECTRICAL 2 muertes · 25 no mortales
- OTHER 1 muerte · 25 no mortales
- FALL OF ROOF OR BACK 796 no mortales
Cronología de incidentes
Operadores bajo este controlador
Minas en registro
- Stonecoal Tipple (T-3) KY
- Smith Underground No 1 KY
- Ivy Creek Mine KY
- #2 KY
- Pyro Prep Plant KY
- Island Creek #1 KY
- Chapperal Plant KY
- Spradlin Branch Mine KY
- Caseyville Dock KY
- Area #6 Mine AL
- Sealy Ann Mountain Mine AL
- Dillon Branch Mine KY
- Central Shop KY
- Dyson Creek Mine KY
- Baker Mine KY
- Carlisle Loadout WV
- Pax South Surface Mine WV
- Files Bottom AL
- Gnadenhutten Strip OH
- Yeshic AL
- Shannon Washer Facility AL
- Pleasant Grove #20 AL
- Black Creek #22 AL
- Red Cedar #5 KY
- Cypress Creek KY
- Saragossa Rail Siding AL
- Prater Creek Mine #1 KY
Muertes bajo este controlador
20 registradasEMPLOYEE WAS EVIDENTLY INSPECTING HIS SHUTTLE CAR CABLE WHICH HAD LOST POWER. HE WAS STANDING AT THE SHUTTLE CAR REEL BETWEEN THE CAR AND CURTAIN APPROXIMATELY 5' AWAY. A SCOOP BACKED THROUGH THE CURTAIN AND HIT THE CAR AND EMPLOYEE, PINNING HIM BETWEEN THE SCOOP AND CAR.
THE VICTIM HAD DUMPED A LOAD OF COAL IN THE BIN. HE PULLED AWAY FROM BIN, GOT OUT OF HIS TRUCK, WENT TO REAR OF TRUCK TO CLEAN OFF LOOSE COAL FROM PUSH BLOCK. THE END LOADER USED TO CLEAN UP T HE BIN, BACKED AWAY FROM BIN, STRUCK HIM, PINNED HIM AGAINST BACK OF TRUCK.
EMPL WAS FOUND BENEATH GOLF CART WITH EXTENSIVE HEAD INJURIES. VICTIM WAS UNCONSIOUS & APPARENTLY NOT BREATHING. INVESTIGATIVE IS BEING CONDUCTED BY MSHA.
IGNITION ON OLD LONGWALL FACE.
IGNITION ON OLD LONGWALL FACE.
IGNITION ON OLD LONGWALL FACE.
IGNITION ON LONGWALL FACE.
IGNITION ON OLD LONGWALL FACE.
INVESTIGATION NOT COMPLETE.
IGNITION ON OLD LONGWALL FACE.
IGNITION ON OLD LONGWALL FACE.
IGNITION ON OLD LONGWALL FACE.
IGNITION ON OLD LONGWALL FACE.
DUST SET OFF BY3SHOOTING FALL OF COAL - #3 UNIT/#2 ENTRY
INDIVIDUAL PICK9D UP ENERGIZED CABLE AND HELD IT BY FEMALE OUTLET.CABLE WAS WIRED WRONG HE GOT SHOCKED THROUGH OUTLET.#3 ENTRY OF #1 UNIT 001.WENT TO GET EXTENSION CABLE FOR POWER SAW 4 X-CUTS OUTBY #1 UNIT 1OWER CENTER.FOUND LYING FACE DOWN IN 3'' WATER.
EMPLOYEE WAS FO6ND LAYING FACE DWON APPROX 20' INSIDE AN OLD ABANDONED UNDERGROUND MINE OPENING. UNKNOWN CAUSES OF DEATH PENDING AUTOPSY REPORT
EMPLOYEE WAS PERFORMING ELECTRICAL WORK ON A BELT STARTER BOX AND CAME IN CONTACT WITH AN ENERGIZED CIRCUIT THE RESULTING ELECTRICAL SHOCK CAUSED CARDIAC ARREST AND DEATH
EMPLOYEE PUT POWER UP ON FEEDER HYDRAULIC HOSE HAD TRAM LEVER ENGAGED FEEDER SWUNG AROUND AND PINNED EMPLOYEE AGAINST RIB EMPLOYEE DIED FROM RUPTURED AORTA AT 1:17 PM
TWO MOTORS HAULING EMPTY TRAILERS RAN TOGETHER-ONE SUPPLY CAR WENT ONTO THE TOP OF ONE MOTOR
Where Costain Group PLC stands on silica, penalties, and injury rate
MSHA's standard limits respirable silica to 50 micrograms per cubic metre, but MSHA publishes dust and quartz as separate files and never the silica figure itself. We derive it per sample, score it against the limit, and set the operator's injury rate against a benchmark built from the full MSHA operator record. With the 26-year penalty trail, contest posture, and fatality history. Delivered as a PDF with the underlying data as CSV.
The federal record itself stays free on this site. What costs money, and why.