ON JUNE 17-1991 THE VICTIM TOOK A DIFFERENT ROUTE THAN THE REST OF EXPLORATORY DRILL CREW AND HIS 1978 FORD 4X4 VAN GOT STUCK IN A MUD HOLE ON AN UNIMPROVED ROAD. IT IS SPECULATED HE GOT COLD AND STARTED AN ONAN GEN SET IN THE BACK OF THE VAN TO RUN A SMALL ELECTRIC HEATER. THE BACK CARGO DOORS OF THE VAN WERE OPEN BUT THE FRONT DOORS WERE CLOSED THERE WAS A HOLD 1/2 WIDE BY 1 1/2
Cimarron Mine Coal
Seguir esta mina
Avísenme cuando se presente un nuevo incidente de la MSHA en Cimarron Mine.
- Muertes
- 1
- Incidentes totales
- 200
- Años en registro
- 1987–1995
- Último incidente
- Nov 1995
Muertes en esta mina
1 registradasIncidentes reportables
199 en archivo (excluyendo las muertes anteriores)1995 · 34 incidentes
ON OR ABOUT 11/16/95 EE WAS DIAGNOSED WITH PROBABLE OCCUPATIONAL ASTHMA FROM OVER EXPOSURE TO M.D.I., AN INGREDIENT IN POYLURETHANE FORM THAT WAS USED AT THE MINE FROM APPROX. DEC OF 94 TO JUN E OF 95.
ON OR ABOUT 11-16-96 EE WAS DIAGNOSED WITH PROBABLE OCCPATIONAL ASTHMA FROM OVER EXPOSURE TO MD.I. AN INGREDIENT IN POLURETHANE FROM THAT WAS USED AT THE MINE FROM APPROX DEC OF 94 TO JUNE OF 95.
EE WAS CUTTING A PIECE OF CONVEYOR BELT TO TAKE HOME.
A ROOFFALL OCCURRED IN THE MAIN RETURN ENTRY 1 AT X CUT 22. THE FALL MEASURED APPROX. 18 FT WIDE BY 30 FT LONG BY 8 TO 10 HIGH. VENTILATION WAS SLIGHTLY IMPAIRED BUT TRAVEL ACCESS WAS BLOCKED. THERE WERE NO INJURIES AND ONLY MINER DAMAGE TOTHE MINE WATER DISCHARGE LINE.
A ROOF FALL OCCURRED IN THE RIGHT MAINS 2 ENTRY, BETWEEN X CUT 24 AND 25. THE FALL MEASURED APPROX. 16 FT WIDE BY 10 TO 15 FT HIGH BY 30 FT LONG. THERE WERE NO INJURES INVLOVLED. VENTILATION A ND TRAVEL ACCESS WAS IMPAIRED.
EE WAS CUTTING THE BONNET OFF OF THE TRIPPER BELT WITH A CUTTING TORCH.
EE WAS HELPING PULL TRIPPER BELT FOR DISASSEMBLY.
A ROOF FALL OCCURRED IN THE INTERSECTION OF THE MAINS #1 ENTRY AND THE #2 FAN ENTRY, BETWEEN X-CUT #23 AND #24 OF THE MAINS #1 ENTRY. THE FALL MEASURED APPROXIMATELY 18 FT. WIDE BY 20 FT LONG BY 6 FT HIGH. THERE WERE NO INJURIES INVOLVED BUT THERE WAS DAMAGE TO AN OVERCAST WHICH CAUSED IMPAIRMENT TO THE VENTILATION.
EMPLOYEE WAS CHIPING OFF A PIECE OF METAL WITH A CHIPPING HAMMER.
DETERIORATION OF THE #3, 7 LEFT START-UP ROOM ENTRY HAS OCCURRED BY CAUSES FROM HEAVY FLOOR HEAVE AND START OF ROOF FALLS AT X-CUT #1 TO #6. ACCESS INTO THIS AREA HAS BEEN DANGERED OFF. VENTIL ATION HAS NOT BEEN IMPAIRED AT THIS TIME, BUT COULD BE AT A LATER DATE.
TRYING TO RELOAD A D.A. RAM THAT HAD ROLLED OUT OF HIS SCOOP'S BUCKET.
A ROOF FALL OCCURRED IN THE 7 LEFT LONGWALL HEADGATE SECTION THE FALL MEASURED APPROX 13FOOT LONG BY 1 5FEET WIDE BY 9FEET HIGH THERE WERE NO INJURIES INVOLVED & VENTILATION WAS NOT IMPAIRED
EE WAS WALKING BELTLINE ENTRY AND WALKED INTO LOW HANGING FIRE VALVE TWISTING HIS NECK.
EMPLOYEE THREW A CRIB BLOCK UNDER SCOOP TIRE TO CHOCK IT AGAINST MOVEMENT. CRIB BLOCK BOUNCED OFF OF TIRE AND STRUCK EMPLOYEE ON THE FOOT.
EE WALKED BACK INTO A CROSS-CUT WITHOUT RESPIRATORY PROTECTION AFTER SPRAYING POLYURETHANE FOAM ON A KENNEDY STOPPING. HE EXPERIENCED CHEST PAIN& AN INCREASED HEART BEAT. IN JULY 1995 HE WAS D IAGNOSED WITH ISOCYANAYE INDUCED ASTHMA. HE MISSED 3 DAYS WORK FOR DR'S VISITS BETWEEN JULY & NOV. 1995.
EMPLOYEE WAS HELPING 3 OTHER EMPLOYEES MOVE A 250 MCM CABLE & STATED WHEN HE PICKED UP THE CABLE & STARTED TO WALK WITH IT HE FELT SOMETHING IN HIS BACK (MIDDLE RT SIDE) START HURTING
EMPLOYEE WAS DRAGGING POWER CABLE FOR PETITO MULE. REINJURED ON 6-12 WHILE REPLACING A PANEL ON POWER CENTER.
EMPLOYEE STEPPED ON A SMALL ROCK CAUSING HIM TO SLIP EMPLOYEE LOST HIS BALANCE & TWISTED HIS BACK
EE WAS STEPPING OVER SOME RIB SLOUGHAGE WHEN HE TURNED HIS ANKLE.
EE WAS LIFTING 2-5 GALLON CANS OF GREASE INTO MANTRIP WHEN HE SLIPPED & FELL, LANDING ON A PIECEOF COAL.
EMPLOYEE WAS CLEANING WAGNER AXLE HOUSING WITH GRINDER IN SHOP AND A SMALL PARTICLE OF STEEL FELW INTO HIS RIGHT EYE SOMEHOUW AROUND THE SAFETY GLASSES WITH SIDE-SHIELDS HE WAS WEARING.
EMPOYEE WAS TRYING TO CLEAN HAWK EYE FOR MUCKER.WHEN HE TRIED TO TIGHTEN CLAMP UP WITH HIS KNIFE SCREWDRIVER, THE KNIFE SLIPPED AND CUT HIS RIGHT INDEX FINGER.
EMPLOYEE WAS WALKING ALONG PAN LINE ON LONGWALL FACE HE WAS MONITORING THE PROGRESS OF A MOTOR BEING CONVEYED TOTHEHEADGATE WHEN HE SLIPPED & STRUCK SPILL PAN
EMPLOYEE WAS STRUCK BYAN AXE ANOTHER EMPLOYEE WAS USING TO SET RIVETWITH WHILE SPLICING A BELT
EMPLOYEE SLIPPED OFF BLOCKING, TRYING TO JACK CANOPY DOWN ON MINER BOLTER. HE HIT HIS LOWER BAKC ON ROOF MAATTS STORED ON MINER.
EMPLOYEE WENT TO PICK UP CRIB BLOCK & FELT A BURNNING PAIN IN HIS BACK & COMPLAINED OF HIS LEG FEELING WEAK.
EE WAS HELPING SET PROPS USING A LADDER. WHEN HE STEPPED OFF HTE LADDER ONTO AN UNEVEN SPOT ON THE GOURND HE TWISTED HIS KNEE AND FELL TO THE GROUND.
EE WAS LOADING 20 INCH VENTILATION TUBE INTO SHUTTLE CAR.
A ROOF FALL OCCURRED IN THE #1 ENTRY OF THE 6 LEFT INACTIVE AREA, X-CUT #54. THE FALL ENCOMPASSED THE THREE WAY INTERSECTION AND MEASURED APPROX. 17 FEET WIDE BY 17 FEET LONG BY APPROX. 10 FEE T HIGH. THERE WERE NO INJURIES INVOLVED AND SLIGHT VENTILATION IMPAIRMENT.
EE WAS INSTALLING SCRAPER ON BELTLINE. AS EE BEGAN TO MOVE SCRAPER, IT FELL AND STRUCK HIM.
A POTENTIAL METHANE IGNITION OCCURRED IN THE #5 RAISE HOLE BEING REAMED OUT. THE POTENTIAL IGNITION OCCURRED AT A LOCATION APPROX. 345 FEET FROM THE SURFACE IN THE 1050 FOOT RAISE HOLE. THERE WERE NO INJURIES AND SLIGHT DAMAGE TO A VENTILATION TUBE ELBOW.
EE STEPPED OFF OF BELT STRUCTURE ONTO A CABLE LYING IN THE WATER.
A ROOF-FALL OCCURED IN THE TWO-WAY INSTERSECTION OF HTE DRAG-LEG TO THE MAIN FAN ADJACENT OT X-CUT #22 OF THE MAINPORTAL RETURNENTYR. THE FAALL MEASURED APPROX 17'W X 17'LX6'H. THERE WERE NO INJUIRES INVOLVED AND NO VENTILATION IMPAIRMENT OR EQUIPMENT DAMAGE.
EMPLOYEE WAS INSPECTION BROKE DYNATRAC CHAIN. WAS HE STEPPED OVER SPIL PLATE A PIECE OF ROCK AND COAL FELL FROMT EH FACE PINNING RIGHT LEG AGAINST SPILL PLATE.
1994 · 52 incidentes
EMPLOYEE WAS WALKING DOWN THE LONGWALL FACE WHILE CUTTING COAL WHEN HE SLIPPED ON THE LOOSE COAL & ROCK ON THE GROUND. THIS LED TO EMPLOYEE SDTRAINING A MUSCLE IN HIS LEFT THIGH. EMPLOYEE'S FI RST DAY OFF OF WORK WAS 12/28/94.
EE WAS RAISING HYDRAULIC CYLINDER WITH COME A LONG. AS CYLINDER WAS SUSPENDED THE CHAIN ON THE COME A LONG BROKE AND EE GOT HIS THUMB CAUGHT IN THE CHAIN.
EMPLOYEE WAS ADVANCING LONGWALL SHIELDS WHEN A CHUNK OF COAL FELL FROM FACE AREA OVER THE PAN AND STRUCK HIM ON THE FOOT.
EMPLOYEE WAS REMOVING A DUKE FROM BETWEEN THE CRUSHER AND THE RIB WHEN HE FELT A PAIN IN HIS BACK.
EMPLOYEE WAS RESETTING A TIMBER UNDER A BEAM. WHEN HE STRUCK THE TIMBER WITH A SLEDGE HAMMER THE TIMBER FELL. WHEN THE EMPLOYEE JUMPED TO GET OUT OF HTE WAY HE FELT A PAIN TO HIS LOWER BACK .
EMPLOYEE WAS INJURED WHEN HE WAS STRUCK BY A SHEAVE BLOCK THROWN AT HIM BY ANTOHER EMPLOYEE DURING NA ARGUMENT.
EMPLOYEE WAS RIDING IN ISUZU PICKUP INTO THE MINE WHEN HHE STRUCK HI HEAD O TEH ROOF OF TH EPICKKUP WHEN THE VEHHICLE STRUCK A HOLE IN THE ROADWAY.
EMPLOYEE WAS DISMANTLING A CRIB TO MOVE TO ANOTHER AREA. HE HAD CLIMBED TH ESIDE OF HTE CRIB TO KOCK OFF THE TOP BLOCKS WHEN THE BLOCK HE WAS HOLDING ONTO OPULLED FREE AND HE FELL TO THE GORU ND. AT THIS TIME AT LEAST ONE CRIB BLOCK FELL ON EMPLOYEE.
EMPLOYEE WAS CHANGING CLOTHES AFTER SHIFT IN THE BATHOUSE WHEN HE BENT OVER TO TAKE OFF HIS SOCKS AND FELT A PAIN TO HIS LWOER BACK.
A ROOF FALL OCCURRED AT THE OUTBY SIDE OF THE #5 RAISE (PROPOSED) SHAFT BETWEEN XCUT #58 & XCUT #59 OF THE 6 LEFT AREA OF THE CIMARRON MINE. THE FALL MEASURE APPROX. 19' WIDE BY 10-12' HIGH BY 15' LONG. THERE WERE NO INJURIES INVOLVED & SLIGHT IMPAIRMENT TO VENTILATION.
EE WAS HELPING HANG CABLE ON L W SET UP.
EMPLOYEE WAS CARRYING PLANK WHEN HE DROPPED IT ON HIS LEG & ANKLE
EMPLOYEE WAS WALKING IN RETURN WHEN HE SLIPPED WHEN HE STEPPED IN SOME WATER & FELL ON HIS RT KNEE
EE WAS MOVING A CRIB BLOCK TO SET SHIELD.
A ROOF FALL OCCURRED IN THE #2 ENTRY XCUT #18 OF THE RT MAINS LEFT AREA OF THE CIMARRON MINE THE FALL MEASURED APPROX 12FT HIGH BY APPROX 18FT WIDE BY APPROX 50FT LONG THERE WERE NO INJURIES I NVOLVED & SLIGHT DAMAGE SAME ELECTRICAL CABLES &WATER LINES THERE WAS SLIGHT IMPAIRMENT TO VENTILATION
EMPLOYEE WAS CARRYING OXYGEN BOTTLE UP LONGWALL FACE
EMPLOYEE WAS PULLING DRILL STEELS OUT OF HOLE WHEN THE STEELS SEPARATED & THE TOP STEEL FELL OUT OF HOLE & STRUCK EMPLOYEE ON THE FINGER
A LARGE AIR BLAST CAME DOWN ENTRY KNOCKING EMPLOYEE INTO SHUTTLE CAR
A METHANE EXPLOSION OCCURRED IN THE 6-LEFT #5 RAISEBOR SHAFT AT APPROX. 11:15 AM ON 9-27-94. TWO MINERS WERE INJURED DUE TO RESULTING AIR BLAST FELT IN THE 6-LEFT SECTION.
A LARGE AIR BLAST CAME DOWN ENTRY KNOCKING EMPLOYEE INTO SHUTTLE CAR
A ROOF FALL OCCURRED IN THE 1 ENTRY X CUT SS OF THE 6 LEFT DEVELOPMENT SECTION. THE FALL MEASURED 17 FT WIDE BY 42 FT LONG BY 10 FT HIGH. THERE WERE NO INJURIES INVOLVED AND SLIGHT DAMAGE TO S OME ELECTRICAL CABLES. VENTILATION WAS NOT IMPAIRED.
EMPLOYEE ALLEGES HE STRAINED HIS NECK. EMPLOYEE WAS STANDING AROUND PERFORMING NO WORK TASKS. THIS REPORT IS BEING FILED ONLY TO TERMINATE CITATION 2930239. THE CITATION WILL BE CONTESTED.
EE WAS CLIMBING LADDER MOUNTED ON FORKLIFT AND HIS FOOT SLIPPED CAUSING EE TO SPIN AROUND AND TWIST HIS LOWER BACK.
A ROOF FALL OCCURRED IN 6-LEFT SECTION AT XCUT 59 AT THE BOTTOM OF RAISE SHAFT #5 MEASURING APPROX. 10' WIDE X 15' LONG X 10-14' HIGH. THIS FALL WAS ON THE CORNER OF THE SHAFT AND ONLYH AFFECT ED 4 ROOF BOLTS CAUSED BY ROOF DETERIORATION DUETO WATERIN ROOF FROM SHAFT.
EE WAS KNOCKING OUT DAMAGED STOPPING WHEN A CINDER BLOCK FELL STRIKING EE ON LEFT LEG AND FOOT.
EE WAS HELPING TO MOVE A HYDRAULIC DUKE (PROP) AND A PIECE OF RIB COAL FELL STRIKING EE ON LEFT LEG.
EE WAS HANDLING CRIB BLOCKS WITH HIS PARTNER AND THE CRIB BLOCK FELL ON EE'S RIGHT FOOT.
ROOFBOLTING AND HIS PARTNER WASHANDING HIM A ROOF BOLT AND DROPPED IT ON EE'S RIGHT FOOT.
EMPLOYEE WAS OPERATING EIMCO SCOOP WHEN HE HIT AHOLE IN THE ROADWAY CAUSING HIM TO JAR HIMSELF INSIDE OPERATORS COMPARTMENT FIRST DAY AWAY FROM WORK WAS SEPT 16 1994
MAKING CONNECTION ON THE RAISEDRILL, FINGER GOT CAUGHT BETWEEN THE WRENCH AND DRIVE HEAD. DRIVE HEAD NOT SECURED FELL, CUTTING FINGERS ON RIGHT HAND.
EMPLOYEE WAS PULLING CABLE FOR FLETCHER ROOF BOLTER AND TRIPPED CAUSIGN HIM TO FALL ON HIS PWSCSR AND THE MINE FLOOR.
EMPLOYEE WAS PUSHING WHEEL BARROW IWHT PARTS IN IT, THE WHEEL BARROW TIPPED AND THE EMPLOYEE TWISTED HIS RIGHT KNEE TRYING TO STOP IT.
ACCIDENT OCCURRED WHEN EMPLOYEE WAS LIFTING 60 INCH ROLLERS OFF OF PICKUP TRUCK AND CARRYING THEM THROUGH A MANDOOR. EMPLOYEE'S FIRST DAY AWAY FROM WORK WAS 8-2-94.
EMPLOYEE WAS HELPING BOLT CAVE AREA IN THE LONGWALL AND WHEN THE DRILL WAS BEING LOWERED AWAY FROM DRILL HOLE, THE DRILL STEEL CAME OUT OF DRILL CHUCK AND FELL OUT OF DRILL HOLE STRIKING EMPLO YEE ON LEFT HAND MIDDLE FINGER.
A ROOF FALL OCCURRED IN ENTRY 3 AT CROSSCUT 37 IN THE RIGHT MAINS LEFT SECTION. THIS FALL DID NOT IMPAIR VENTILTION OR BLOCK ESCAPEWAYS. THE EXACT SIZE OF THE FALL COULD NOT DETERTMINED DUE TO CONDITIONS IN THE SECTION.
A ROOF FALL OCCURRED IN THE #1 BELT & HEADGA TE ENTRY OF THE 5LLW SECTION APPROX 3FT INBY XCUT #17 RIBLINE THE FALL MEASURED APPROX 17FT WIDE BY 30FT LONG BY 10FT TO 12FT HIGH THERE WERE NO I NJURIES INVOLVED & SLIGHT DAMAGE TO EQUIPMENT VENTILATION WAS NOT IMPAIRED
VICTIM WAS DRIVING SCOOP AND RAN OVER A HOLE OR BUMP AND HIT HIS HEAD ON CANOPY JAMMING NECK.
A ROOF FALL OCCURRED IN THE FACE INTERSECION OF #3 ENTRY OF THE RIGHT MAINS LEFT AREA. THE FALL MEASURED APPROXIMATELY 23 FT WIDE X 24 FT LONG X 10 FT HIGH. THERE WERE NO INJURIES AND NO VENTI LATION IMPAIRMENT.
A ROOF FALL OCCURRED IN THE 5 LEFT # 1 ENTRY BELTLINE 46FT INBY X CUT #9. THE ROOF FALL MEAS URED APPROX 10 FT WIDE X 12 FT LONG X 6 FT HIGH.THIS AREA FELL WHILE ROCK LOCKING ROOF WITH RESIN INJECTIONS THIS AREA WAS BOLTED WITH 7 GROUTED COMPRESSION BOLTS. THERE WERE NO INJURIES AND NO IMPAIRMENT TO VENTILATION.
A ROOF FAL LOCCURED APPROX BETEWEEN 5-25-94 AND 5-26-94NIN THE BLEEDER ENTRY INTERSECTION AT APPROX SPAD #262 10' OUTBY THE NUMBER 1 BLEEDER EVALUATION POINT. THE FALL MEASURED APPROX 6' HIHG X 16' WIDE X 25' LONG. T HERE WERE NOT INJURIES INVOLVED AND NO IMPAIRMENT OF VENTILATION.
A ROOF FALL OCCURRED BETWEEN 1000AM, 4-25-94 AND 1000AM, 5-3-94. IT WAS DISCOVERED BY THE FIRBOSS DURING HIS WEEKLY EXAM OF THE BLEEDERS. THE FALL MEASURED APPROX. 8' H X 19' W X 23' L AND IS LOCATED APPROX. 30' OTUBY THE #3 RAISE SHAFT. THE CAUSE OF THE FALL APPEARS TO BE WATER SEEPAGE WHICH WEAKENED THE ROCK STRATA ABOVE THE 6' BOLTS.
EMPLOYEE WAS LIFTING A BAG OF ROCK DUST AND FELT A PAIN ON THE LEFT SIDE OF BACK. FIRST DAY OFF OF WORK WAS 4-23-94.
EMPLOYEE WAS GETTING INTO WAGNER SCOOP WHEN HIS FEET SLIPPED AND HE FELL ONTO THE OUTSIDE WALL OF OPERATOR'S COMPARTMENT RESULTING IN PAIN IN HIS TAILBONE AND LOWER BACK.
EMPLOYEE WAS STEPPING OFF OF ROOF BOLTER WHEN HEFELT A PAIN TO HIS LOWER BACK.
AT APPROX 1:30 AM A ROOF FALL OCCURRED N THE NO 1 ENTRY OF THE 5 LEFT HEADGATE SECTION THE FALL MEASURED 16FT WIDE 10FT LONG & 8FT HIGH & FELL ON THE STAGE LOADER NO INJURES OCCURR4ED MEN EXIT ED FACE FROM TAILGATE CAUSE OF FALL WAS DUE TO ABUTEMENT PRESSURES
EMPLOYEE SITTIN GAT HEAD GATE CONTROL PANEL WITH HIS BACK TO THE RIB. THE RIB GAVE WAY KNOCKIN GOUT A HYDRAULIC PROP AND HTE RI BSTRUCK HIM ON THE BACK BRUISIN IT.
EMPLOYEE WAS CARRYING A PLANK & SLIPPED CAUSING PLANK TO BOUNCE UP & STRIKE EMPLOYEE'S CHIN. RESULTED IN SEVER SUTURES REQUIRED TO CLOSE CUT.
EMPLOYEE WAS PULLING INPUT CABLES THROUGH LONGWALL HEADGATE WHEN HE ATTEMPTED TO PULL CABLE FROM OUTBY GROUND & PULLED OR STRAINED MUSCLE ON HIS RIGHT LOWER BACK.
EMPLOYEE WAS SHOVELING ON BELTINE.
EMPLOYEE WAS LIFTING SEVERAL ROLLS OF ROCK DUST HOSE FROM THE BACK OF TRUCK THEY SLIPPED FROML HIS HANDS & CAUGHT HIS LITTLE FINGER & BENT IT BACK
EMPLOYEE WAS CARRYING A BAG OF ROCK DUST & SDLIPPED & FELL INJURING HIS LOWER BACK.
EMPLOYEE WAS HELPING SCOOP OPERATOR UNLOAD BELT STRUCTURE AND SLIPPEDINA HOLE AND THE WEIGHT OF THE STRUCTURE WENT ON LOWER BACK. EMPLOYEE TRIED TO CATCH FOOTING. EMPLOYEE WAS WALKING BACKWAR DS WHENHE SLIPPED OFF LEDGE.
1993 · 36 incidentes
EMPLOYEEW AS ASSEMBLIGNA KENNEDY STOPPIGNAND WAS SLIDIGN A KENNEDY METAL PANEL APART AND WHIE DOIGN SO, HE CUT THE SMALL FINGE RON HIS RIGHT HAND.
EMPLOYEE WAS INSTALLING ROOF BOLT ABOVE HIS HEAD WHEN HE STRUCK THE ROOF WITH HIS HEAD AND FELT PAIN IN HIS NECK AND SHOULDERS.
EE WAS OPERATING TRACTOR WHEN HE LOST CONTROL DUE TO EXCESS SPEED AND POOR BRAKES ON THE TRACTOR. WHEN HE LOST CONTROL, TRACTOR RAN INTO RIB AND TURNED ONTO ITS SIDE. AT THIS POINT IN TIME EE FELL OFF. EE WORKED FOR 4 DAYS AFTER ACCIDENT. FIRST DAY OFF WORK WAS 12-8-93.
EE WAS IN 3 L.W. SET UP ROOM SETTING CRIBS AND LIFTING CRIBS.
EE WAS LAYING IN CONVEYOR PAN & KNEELING IN PUSHING A 1" CABLE THROUGH THE BOTTOM TO CONNECT TO FACE CONVEYOR CHAIN. WHEN HE GOT BACK UP HIS LEFT KNEE POPPED, REINJURING AN OLD INJURY TO HIS K NEE.
EMPLOYEE WAS WALKING ACROSS OVERCAST AT CROSS #23 RM LEFT & CAUGHT HIS BACK ON A ROOF BOLT.
EE WAS CARRYING WEDGES. HE SLIPPED AND FELL AND LANDED ON HIS BACK, BRUISING IT.
EMPLOYEE WAS UNLOADING CRIB BLOCKS OUT FO SHUTTLE CAR. HE SLIPPED AND FELL, STRIKING HIS BACK AND RIGHT ARM ON HIS FILTER SELF RESCUER. EMPLOYEE WORKED UNTIL 9-27-93. HIS FIRST DAY AWAY FROM W ORK WAS 9-28-93 DUE TO CONTUSION OF LOWER BACK.
EMPLOYEE WAS CARRYING A BELT STRUCTURE SIDE RAIL & LOST HIS FOOTING & SLIPPED & FELL AGAINST HIS LEFT UPPER LEG & HIP AREA.
EMPLOYEE WAS OPERATION EIMCO SCOOP AND ALLEGES THAT WHEN GETTING ON AND OFF OF SCOOP HE PULLED SOMETHING IN HIS STOMACH. EMPLOYEE WAS OPENING DOWN WHEN WEIGHT OF DOOR PULLED HIM.
A ROOF FALL OCCURRED IN THE #1 ENTRY, X-CUT 357 OF THE 5 LEFT STARTING ROOM. THE FALL MEASURED APPROX. 24' WIDE X 38' LONG X 10' HIGH. THERE WERE NO INJURIES INVOLVED AND SLIGHT DAMAGE TO SOME ELECTRICAL CABLES. VENTILATION WAS NOT IMPAIRED
EMPLOYEE WAS ROOF-BOLTING WITH FLETCHER BOLTING MACHINE. THE DRILL STEEL WAS HUNG UP IN HOLE. EMPLOYEE HAD HIS THUMB OVER CHUCK AND STEEL CAME LOOSE STRIKING EMPLOYEE'S THUMB.
EMPLOYEE WAS WALKING IN CROSSCUT #12 RT MAINS & STEPPED ON A OBJECT & TWISTED HIS LEFT KNEE
EMPLOYEE WAS FIREBOSSING BELT LINES AND TWISTED HER RIGHT FOOT SPRAINING HER ANKLE.
EMPLOYEE WAS GETTING OFF BUS AT CIMMARON MINE & STUMBLED ON 1ST STEP & FELL
EMPLOYEE STATED HE WAS STANDING AT L.W. HEADGATE WATCHING THE COAL COME DOWN THE CONVEYOR AND A HYDRAULIC JACK (DUKE) FELL OVER AND HIT THE FRONT OF HIS HARD HAT AND THEN FELL ON HIS FOOT.
EMPLOYEE WAS LINING AND LEVELING BELT STORAGE UNITS, INVOLVING USING STEP JACKES AND HEAVY LIFTING. HE WAS USING STANDS TO LEVEL UNITS.
EE WAS RIDING ON MANTRIP GOING OUT AND MANTRIP HIT A HOLE IN ROADWAY JARRING HIS BACK.
EMPLOYEE WAS OPERATING SHUTTLE CAR & RAN OVER A ROCK JOLTING IM OUT OF SEAT & CAME DOWN HARD ON SEAT CAUSING INJURY TO LOWER LEFT BACK 1ST DAY AWAY FROM WORK 06-24-93
EE WAS CARRYING A WATER PUMP ACROSS OVERCAST. EE BELIEVES THAT HE PULLED SOMETHING IN HIS BACK WHILE CARRYING PUMP. EE EXPERIENCED PULLED MUSCLE IN HIS LOWER BACK.
EMPLOYEE WAS ALIGNING REAR OF MOBILE BELT TAILPIECE. HE WAS USING A HYDRAULIC SINGLE PROP TO PUSH TAILPIECE OVER, WHEN RIB SLOUGHED OFF STRIKING HIM.
EE SAID SHE WAS WALKING ALONG BELTLINE AND SLIPPED SHE SAID SHE GRABBED THE BOLT STRUCTURE AND TWISTED HE BACK.
EMPLOYEE CAME OT WORK WITH BACK PAINS FROM AN OLD INJURY. EMPLOYEE STATED THAT HE HAD BEEN SHOVELING MUD ON 3-8-93 ALONG BELTLINES.
EE WAS CARRYING A CRIB BLOCK WHEN HE STEPPED ON A ROCK AND SLIPPED AND SPRAINED HIS ANKLE.
EE WAS TRYING TO REMOVE A CRIB BLOCK OUT OF HIS WAY THERE WAS AN EXCESS AMOUNT OF MUD IN THE AREA AND WHEN HE TRIED TO PICK UP THE CRIB IN THE MUD HE INJURED HIMSELF.
EMPLOYEE WAS PUTTING CAP ON CRIB AND A PIECE OF COAL BROKE LOOSE, HITTING PERSON PERSON ON HARD HAT.
EMPLOYEE WAS WORKING ON RIGHT DRILL LEAD JUNCT- ION HE STRAIGHTENED THE HOSE AND PUT HIS HAND ON THE CHUCK TO FEEL FOR SUCTION. THE DRILL OPERATOR WAS LOWERING STEEL FROM THE ROOF WHEN IT SLIPPED AND FELL DOWN WITH THE END STRIKING THE RIGHT RING FINGER, SMASHING THE BONE AND LACERATING THE FINGER.
EMPLOYEE WAS REHANGING A 6" AIRLINE. HE WAS HELPING LIFT THE LINE AT A COULPLER WHEN THE PIPE BROKE. THE AIR BLAST KNOCKED THE EMPLOYEE TO THE GROUND AND HE STRAINED HIS BACK.
EMPLOYEE WAS MOVING A CHAIR IN THE BATH HOUSE.
EMPLOYEE WAS STEPPING OFF OF ROOF BOLTER & CAUGHT FOOT ON HITCH TRIPPING & FALLING HE TRIED TO CATCH HIMSELF WITH OTHER LEG
EE WAS MOVING PROPS HE PICKED UP ONE END OF A PROP AND WAS WALKING BREAKWARDS STUMBLED EVEN A I BEAM FELL DOWN AND STRUCK MOTHER BEAM WITH LOWER BACK.
EMPLOYEE WAS PULLING SLACK OFF SHUTTLE CAR REEL TO HANG UP TRAILING CABLE TO MOVE ROOFBOLTING MACH UNDER. HE GRABBED A PLACE ON CABLE WHERE THERE WAS A CUT THROUGH THE OUTER COVER & INTO ONE OF THE PHASE LEAD INSULATION & RECIEVED A SHOCK.
EMPLOYEE WAS WALKING UP TO THE STACKER BELT AREA. HE SLIPPED ON SOME ICE, FALLING ON HIS BACK AND LANDED ON HIS SELF RESCUE UNIT.
EE WAS HANGING 3 INCH PLASTIC PIPE AND SLIPPED AND FELL OFF OF THE 2ND STEP OF A 4 FT LADDER FALLING AND HITTING HIS SIDE.
A ROOF FQALL OCCURRED IN X-CUT #11 OF THE RIGHT-MAINS LEFT, BETWEEN ENTRY #2 AND ENTRY #3. THE FALL MEASURED APPROX. 16' WIDE X 28' LONG X 18' HIGH. THERE WERE NO INJURIES INVOLVED AND SLIGHT VENTILATION IMPAIRMENT TO THE IDLE INBY 6 LEFT SECTION. THE STOPPING IN THE X-CUT WAS BROKEN INTO THE BELTLINE.
A WELDER WAS WELDING A SECTION OF CASING PIPE TOGETHER IN PREPARATION OF CASING A BROREHOLE INTO THE MINE WHEN A PIECE OF HOT SLAG DROPPED TO THE GROUND AND IGNITED A METHANE BLEEDEA WITHIN TH E AREA OF THE COLLAR AROUND THE PIPE CASING.
1992 · 30 incidentes
EMPLOYEE WAS DRILLING HOLE WITH A GOPHEN DRILL AND THE UP PRESSURE WAS INADVERTENTLY RELEASED. THE DRILL STEEL FELL OUT OF ROOF PINCHING EMPLOYEE'S FINGER ON RIGHT HAND.
POSSIBLE MIS-ALIGNING OF THE SWITCH BLADES, CUAISING AN ARCING WHICH LEAD TO THE INSULATION CATCHING ON FIRE. AND THE EMPLOYEE WHO WAS EXTINQUISHING THE FIRE INHALED SOME SMOKE PRIOR TO DANCI NG HIS SCSR AND APPARENTLY STRUCK HIS RIB CAGE AGAINST THE RIB OR EQUIPMENT.
EMPLOYEE WAS GETTING INTO BACK OF 5 LEFT PICK-UP, THE FRAME OF CAMPER SHELL REAR DOOR FLIPPED OPEN, STRIKING EMPLOYEE ON LOWER LIP.
EE HAD RIGHT HAND ON TOP OF DRILL HEAD ROCK THE SIZE OF FOOTBALL SMASHED TOP OF HAND.
EMPLOYEE WAS HANDLING CABLE RIB COAL CAME FREE STARTING EMPLOYEE WHO STUMBLED & HURT RT WRIST SUPPRTING HIMSELF
EE WAS USING A CABLE COME A LONG WHICH SLIPPED WHILE HE WAS USING IT PINCHING HIS RIGHT THUMB AREA.
EMPLOYEE HAD CONNECTED A WATER PUMP TO THE DISCHARGE LINE. A VALVE WAS OFF DOWN TEH LIEN AND THE CUPPLER HE HAD HOOKED UP TO WAS NOT PINNED IN. HE STARTED THE PUMP AND WHEN IT BUILT UP PRESS URE, THE TEST VALVE FLEW OFF. HITTING HIKM ON THE RIGHT ARM AND BACK.
A ROOF-FALL OCCURED INT EH NUBMER ONE BELT ENTRY OF THE 5 LEFT ENTIRES, BETWEEN X-CUT #21+#23. THE FALL MEASURED 16'WX40'LX9'H. THERE WERE NO INJURIES INVOLVED AND NO VENTILATION IMPAIRMENT. THERE WAS SOME DAMAGE TO 40' OF BELT STRUCTURE.
EMPL HELPING RIGHT BOOM ROOFBOLTER CLEAR SUCTION HOSE OBSTRUCTION. KNEELING ON BOTTOM NEAR THE DRILL HEAD BETWEEN BOLTER AND RIB. A ROCK 4' X 4' X 1'THICK FELL FROM ROOF ALONG RIB LINE STRIK ING RIGHT BOOM ROOFBOLTER AND THEN LANDING ON EE BACK RESULTING IN 2 HAIRLINE FRACTURES OF RIGHT FOOT.
EMPL OPERATING RIGHT SIDE ROOFBOLTER. WAS ON THE DRILLING PLATFORM AND LEANED OVER CONTROLS TO HELP UTILITYMAN CLEAR OBSTRUCTION ON SUCTION HOSE. ROCK 4' X 4' X 1'THICK FELL FROM ROOF ALONG RIB LINE AND STRUCK EMPL FORCING HEAD AND RIGHT TRUNK INTO MACHINE RESULTING IN LACERATIONS TO RIGHT EYELID,CHEEK & CHIN REQUIRING 45 SUTURES. FRACTURED 5 RIBS,CONCUSSION TO HEAD ,CONTUSIONS
EMPLOYEE WAS CARRYING A ROLLER FOR 5 LEFT TAKE-UP FIRST DAY AWAY FROM WORK 09-28-92
EMPLOYEE BENT OVER TO PICK UP A CHAIN. WHEN EMPLOYEE STRAIGHTENED UP, HE STRAINED HIS BACK.
ROOF FALL OCCURRED AT AND ABOVE ANCHORAGE ZONE IN #3 RETURN ENTRY OF 5 LEFT ENTRANCE BETWEEN X-CUT 8 & 10. FALL MEASURED 14'LONG X 11'WIDE X 7'HIGH. NO INJURIES,NO VENTILATION IMPAIRMENT OR EQ UIPMENT DAMAGE.
10966F FALL IN THE BLEEDER ENTRY OCCURRED BETWEEN 07-20-92 AND 07-27-92.THE FALL WAS DISCOVERED DURING THE WEEKLY EXAMINATION OF THE BLEEDER AND MEASURED 17'W X20'L X6'H.ADEQUATE VENTILATION W 12063OWING OVER THE CAVE.READINGS TAKEN WERE METHANE 0%,OXYGEN 20.5%,CARBON MONOXIDE 1PPM.THE FALL WAS LOCATED APPROX 240 FT INBY THE NO 3 RAISE SHAFT.
54736YEE WAS WALKING THROUGH MUD WHEN HE STEPPED ON A PIECE OF WIRE AND IT WENT THROUGH THE BOTTOM OF HIS BOOT,PUNCTURING HIS FOOT.
54736YEE WAS MOVING A SIGHT STRING OUT OF THE WAY WHEN HE PULLED A SPAD FROM THE ROOF.THE SPAD STRUCK HIS LEFT INDEX FINGER CAUSING A SMALL LACERATION.SEVERAL DAYS AFTER THE WOUND BECAME INFEC 35401ND HE WAS HOSPITALIZED.
EMPLOYEE HAD HIS LEFT ARM ON TOP OF AN I-BEAM THAT WAS SETTING ON TOP OF THE ROOF BOLTER CANOPIES. THE OTHER ROOF BOLTER KICKED AT THE PANIC BAR TO SHUT THE MACHINE OFF SO THEY COULD REPOSITI ON THE BEAM. HIS FOOT HIT THE LEVER TO RAISE THE CANOPY AND IT WENT UP, PINCHING THE EMPLOYEE'S WRIST BETWEEN THE I-BEAM AND THE ROOF DOING SEVERE SOFT TISSUE DAMAGE TO HIS LEFT ARM.
A ROOF FALL OCCURRED ABOVE THE ANCHORAGE ZONE IN THE INTERSECTION OF X-CUT #16 IN THE #2 HAULAGE (INTAKE) ENTRY OF 5 LEFT AREA. THE FALL MEASURED APPROX. 40' LONG BY 17' TO 18' WIDE BY 14' HIG H. THERE WERE NO INJURIES INVOLVED AND NO VENTILATION IMPAIRMENT, WITH DAMAGE TO APPROX. 45' OF PRIMARY CABLE. THE CAUSE BEING A GEOLOGY AREA OF SLICKEN-SIDED MATERIAL.
EMPLOYEE ADN CO-WORKER WERE MOVING BELT STRUCTURE WHEN A CHANNEL RAIL FELL ON HER IGHT FOOT, CAUSIGN A HAIR LINE FRACTURE.
EMPLOYEE WAS HOLDING VENT TUBE OVER HEAD. TUBE SHIFTED, CAUSING VENTING TO CHANGE POSITION. THIS RESULTED IN EMPLOYEE PULLING A MUSCLE IN HIS BACK.
THE LEFT SIDE OPERATOR WAS ON THE BOTTOM AT THE LEFT BOOM POSITIONING A PIECE OF ROOF SCREEN TO BE RAISED WITH THE ATRS.THE RIGHT SIDE OPERATOR RAISED THE ATRS AND THE ATRS FOOT ASSEMBLY CAME DOWN ON THE INJURED EMPLOYEES RIGHT LOWER LEG,BREAKING BOTH BONES.
EE WAS RAISING BOOM ON FLETCHER ROOF BOLTER. THE BOOM HUNG UP AND WHEN IT POPPED LOOSE, IT STRUCK HIM UNDER THE CHIN, LACERATING IT, REQUIRING 9 SUTURES.
EE WAS GETTING OFF THE DRILLING DECK OF ROOF BOLTER AND TWISTED RIGHT ANKLE, STRAINING IT.
EMPLOYEE WAS LEANING ON ROOF BOLTER TALKING TO OPERATOR.THE OPERATOR LOWERED THE CANOPY PINCHING HIS RIGHT HAND IN THE JACK COLLAR FRACTURING THE INDEX FINGER OF HIS RIGHT HAND.
EE ALLEGES HE WAS CARRYING A CRIB BLOCK WHEN HE STEPPED ON A ROCK AND PULLED A MUSCLE IN HIS LOWER BACK.
EE ALLEGES HE WAS BENDING A PIECE OF LOT ROD. HE CONTACTED THE HOT STEEL WITH HIS LEFT WRIST CAUSING A 2 BARN. HE MISSED 2-28 AND 2-29 DUE AND INFECTION.
EMPLOYEE WAS MOVING LARGE STEEL PLATE WITH A PRY BAR IN CONJUNCTION WITH ANOTHER EMPLOYEE WHO WAS HOISTING THE STEEL WITH A COME-A-LONG AS TENSION WAS APPLIED TO THE CHAIN THE NUT & PLATE WHIC H WAS HOLDING THE COME-A-LONG IN PLACE CAME LOOSE WITH THE PLATE STRIKING VICTIM ON THE LEFT FINGER (INDEX)FRACTURING IT
EMPLOYEE WAS BOLTING ON FLETCHER MACHINE WHEN BOOM BOUNCED WHEN MOVING IN & OUT CAUSING VICTIM TO COME IN CONTACT WITH SHARP EDGE ON ATRS (CAUSING SMALL CUT REQUIRING 4 STITCHES)
EMPLOYEE WAS HELPING 6 OTHER EMPLOYEES LIFT AN I-BEAM UP ON THE HEADS OF THE ROOF BOLTER AND PULLED HIS BACK MUSCLES.
A ROOF FALL OCCURED ABOVE THE ANCHORAGE ZONE IN THE INTERSECTION OF X CUT13, IN THE 1 BELT ENTRY OF THE 5 LEFT SECTION THE FALL MEASURED APPROX. 53 FT LONG X 16 TO 18 FT WIDE X 22 FT HIGH THRE R WERE NO INJURIES INVLVED AND SLIGHT VENTILATION IMPALEMENT WITH DAMAMGED TO APPRXO. 53 FT OF BOLT STRUCTURE THE PROBABLE CAUSE BEING A GEOLOGY AREA OF SLICKAN INSIDED MATERIAL WITH SPONSE O
1991 · 11 incidentes
A ROOF FALL OCCURRED ABOVE THE ANCHORAGE ZONE IN THE INTERSECTION OF X-CUT #9 IN THE #1 BELT ENTRY OUTBY THE 5 LEFT SECTION.THE FALL MEASURED APPROXIMATELY 17 FT LONG X30 FT WIDE X2 FT HIGH.TH ERE WERE NO INJURIES INVOLVED AND SLIGHT VENTILATION IMPAIRMENT,WITH DAMAGE TO APPROX 20 FT OF BELT STRUCTURE AND RATIO FEEDER CABLE.THE PROBABLE CAUSE BEING A SLICKED/SIDED GEOLOGY WITH WET
EE REPAIRMAN WAS LIFTING PLANETARY INTO POSITION ON 5L MINER.
EMPLOYEE WAS HELPING BOLTERS INSTALL RIB MATS WHEN A PIECE OF RIB CAME LOOSE AND STRUCK HIM ON THE LEFT LEG AND FOOT BRUISING HIS LEFT FOOT.
EMPL WAS WELDING TOP PART OF STAIRWAY HANDRAIL. HE WAS HOLDING RAIL WITH RIGHT HAND & WAS REACHING FOR SOME WELDING ROD WITH LEFT HAND WHEN RAIL FELL & HIT LEFT THUMB.
EMPLOYEE WAS OBSERVING CONTINUOUS MINER IN PRODUCTION, WHILE IT WAS BACKING UP TO CLEANUP, THE TRAILING CABLE BECAME ENTANGLED WITH A ROCK AND AS EMPLOYEE REACHED DOWN TO FREECABLE THE ROCK TI PPED OVER PINCHING EMPLOYEE RIGHT HANFD AGAINST FRAME OF MACHINE.
EMPLOYEE WAS RIDING IN BACK SEAT OF ALLIS CHALMER TRACTOR WHEN IT HIT A DIP IN ROADWAY AND EMPLOYEE STRUCK HER HEAD ON THE ROOF.
INTERSECTION OF XCUT #1 BETWEEN ENTRIES #2 & #3 OF 5TH LEFT SECTION IN ENTRY #2 EXPERIENCED ROOF FALL ABOVE ANCHORAGE ZONE OF ROOF BOLTS WITH PROBABLE CAUSE BEING SLICKEN SIDED GEOLOGY AREA.
CLEANING MATERIAL TRAPPED HIS ARM IN BETWEEN THE FRAME AND THE MAST
A SURFACE SHOP REPAIRMAN WAS PERFORMING A JOB OF WELDING A COLLAR AROUND THE TOP OF A DRILL HOLE PIPE CAUSING, WHEN A MATHANE BLEEDER WAS IGNITED BETWEEN THE PIPE AND THE EARTH HOLE.
THE FACE ITNERSECTION OF #2 ENTRY AND TO #3 ENTRY OF THE RIGHT MAINS SECTION EXPERIENCED A ROOF FALL WITH PROBABLY CAUSE BEING A SLICKEN/SIDED GEOLOGY AREA ACCOMPAINED BY A LARGE POT WITH WATE R INT HE STRATA. ABOVE THE ANCHORAGE ZONEOF THE ROOF BOLTS.
EMPLOYEE WAS HELPING MACHINIST USE LARGE PRESS AND THEY WERE USING A PIECE OF PLATE TO HOLD UP A LARGE BAR OF METAL THAT WAS BEING PUT INTO THE PRESS. WHEN WEIGHT SHIFTED, THE PLATE FELL, STRI KING EMPLOYEE'S RIGHT FOOT.
1990 · 5 incidentes
REMOVING TAKE UP JACK FROM BELT DRIVE DISCONNECTED HOSE IT STRUCK HIM ON BOTH SIDE OF FACE FRACT L CHEEK BONE
ROOF FALL ABOVE ANCHORAGE ZONE OCCURRED BETWEEN 3PM 9-19 AND 630AM 9-20 IN 4TH LEFT BELT ENTRY.DIMENSION-9'H X 17'W X 30'L. 50'INBY X-CUT 12..PROBABLE CAUSE-A FAULT WITH SLICKENSIDE GEOLOGY. LOGY.
DRILLING HOLE INSTALL RF BOLT OTHER OPER SHUT OFF MACHINE TO ALLOW MANTRIP TO PASS, ALIGNING DIRLL HEAD SMASHED MIDDLE FINGER OF L BETWEEN THE STEEL AND JAWS SEVERING THE TIP OF FINGER
EMPLOYEE WAS WORKING WITH TWO OTHER MEN CHANGING A TROUGH ROLLER ON THE 4TH LEFT BELTLINE. HIS LITTLE FINGER OF HIS RIGHT HAND GOT CAUGHT BETWEEN THE ROLLER AND THE BELT. A LACERATION REQUIRIN G FOUR SUTURES RESULTED.
SOMEONE BETWEEN 2:40 P.M. FEBRUARY 1, 1990 AND 7:20 A.M. FEBRUARY 2, 1990, THE X-CUT #5, MIDDLE ENTRY INTERSECTION OF THE 5TH LEFT SECTION EXPERIENCED A ROOF FALL ABOVE THE ANCHORAGE ZONE. DI MENSIONS APPROX 30'L X 23'W X 10'H. THIS SECTION HAS BEEN IDLE SINCE FORE X-MAS 89. INTERSECTION B MEL SHIVELY 2-2-90. PROBALBE CAUSE: SLICK N'SLIDE GEOLOGY ABOVE A POT ACCOMPANIED BY WATE
1989 · 2 incidentes
A ROOF FALL ABOVE THE ANCHORAGE ZONE OCCURRED SOMETIME BETWEEN NOON 06-06-89 AND 8:00 AM 6-7-89 IN THE 4TH LEFT BELT ENTRY.DIMENSION 8'HX20'LX17'WIDE.50' OUTBY X-CUT 28+100'WAY X-CUT 27.INVEST IGATED 06-08-89 BY(NAME).PROBABLE CAUSE WAS A WATER SLIP.THIS IS AN IDLE AREA OF THE MINE AND VENTILATION WAS NOT CONSTRUCTED.
INJURED WAS WALKING FROM THE PORTAL OF THE MINE, APPARENTLY STEPPED WRONG AND TWISTED HIS RIGHT ANKLE AND LOWER PART OF RIGHT LEG.
1988 · 4 incidentes
STOPPED TO LIFT RIB OFF ROADWAY & FELT PAIN IN GROIN AREA
SLIPPED ON ICE SPRAINED ANKLE.
GREASING ROLLER WITH BELT RUNNING.BELT STOPPED.TAKEUP ROLLER CAME BACK AND RAN OVER I.NAME FOOT.
SLIPPED ON SHIE5D RELAY BAR & TWISTED BACK
1987 · 25 incidentes
REPLACING COUPL9R ON MOTOR (CHUNK BREAKER) HE HAD HAND IN BETWEEN MOTOR AND FLANGE, COFFIN HOIST HOOK SLIPPED, HAND WAS CAUGHT BETWEEN MOTOR AND FLANGE.
WHILE DRIVING M5NTRIP TO 4 LET, HE HIT A ROCK IN ROADWAY, JERKED STEERING WHEEL OUT OF HIS HAND.
CARRIED PROP TO3MANDOOR, SLIPPEDD WITH PROP AND IT HEAD ON TOP OF MANDOOR.
SUBJECT WAS PIC5ING UP WINCH CABLE AND STATED TO ANGELO THAT HE HURT HIS BACK AGAIN.
HITTING CAP INT2 CRIB WITH BALL PEEN HAMMER.HIT LEFT INDEX FINGER INSTEAD.
KICKING COAL OF0 SHIELD BSE HIT INSTEP ON SHIELD BASE SADDLE.
PULLING CABLE O6T OF ROOF BOLTER REEL TO DO MONTHLY GROUND CHECK TEST.AS HE WAS PULLING HE FELT PAIN IN LOWER BACK.
CLEANING MUSD O6T OF DRILL STEELS WITH A WIRE AND RAG. HE WAS PULLING THE WIRE OUT WHEN HE HAD A SHARP PAIN IN HIS LEFDT SHOULDER JOINT AND THAT HIS LEFT HAND FELT LIKE IT WAS GOING TO SLEEP.
AN UNPLANNED RO2F FALL OCCURRED AT AND ABOVE THE ANCHORAGE POINT IN THE INTERSECTION OF THE LAST OPEN X-CUT AND SET UP ROOM IN THE NON-PRODUCING SECTION 4TH LEFT, M.M.U. 004-0. THE AREA OF THE FALL MEASURED A1PROX 8' X 9' HIGH BY 17'LONG. NO INJURIES OR VENTILATION IMPEDIMENT OCCURRED. ALL SAFETY PRECAUTIONS WERE TAKEN AND THE AREA PROPERLY SECURED
PROP FELL HITT3NG EMPLOYEE IN BACK OF HEAD
FELL WHILE BREA5ING ROCK THAT WA CAUGHT IN THE RIGHT MAINS LG. THE BELT WAS WET AND SLIPPERY CAUSING HIM TO LOOSE FOOTING.
VICTIM WAS TRAM4ING FLETCHER ROOF BOLTING MACHINE.PAN OVER A CHUNK IN ROADWAY CAUSING THE MACHINE TO "JUMP" AND JARRED LOWER BACK.
UNPLANNED ROOF 0ALL AT AND ABOVE ANCHORAGE POINT IN INTERSECTION OF X-CUT #2 IN 3RD LEFT LONGWALL BELTLINE.AREA OF FALL 6-9'HIGH X 21'LONG X 23'WIDE.NO INJURIES OR VENTILATION IMPEDIMENT OCCUR RED.ALL SAFETY 1RECAUTIONS TAKEN AND AREA PROPERLY SECURED.
DRIVING MANTRIP2 HIT BAD HOLE, STEERING WHEEL HIT THUMB.
PULLING 6 IN ST9EL PIPE THROUGH MANDOOR, MAN ON OUTBY PULLED PIPE AND IT SLIPPED OFF MANDOOR CATCHING HIS FINGERS BETWEEN PIPE AND MANDOOR. CUT INDEX FINGER AND MIDDLE FINGER
WAS HELPING WIT2 THE RE-SETTING OF DUKES, SLIPPED AND FELL.
INJURED WAS DRI5LING A HOLE IN THE ROOF. HE LEFT THE DRILL STEEL IN THE ROOF AND TURNED AROUND TO GET ANOTHER LENGHT OF STEEL. THE STEEL IN THE ROOF FELL OUT AND STRUCK HIS HAND WHICH HE HAD ON TOP OF THE 8RILL HEAD.
DISCHARGE LINE 7AME OFF THE PUMP AND STRUCK I NAME ON THE RIGHT LEG. PUMP ON DISCHARGE LINE WAS PLUGGED AND UNDER A LOT OF PRESSURE.
AN UNPLANNED RO2F FALL OCCURRED AT THE ANCHORAGE POINT IN THE INTAKE HAULAGE ENTRY INBY X CUT 15 OF M.M.U. 005-0 SECTION. THE FALL MEASURED APPROX. 8 FT HIGH X 17 FT WIDE X 20 FT LONG NO INJUR IES OR VENTILAT3ON IMPEDIMENT OCCURRED. ALL SAFETY PRECAUTIONS WERE TAKEN AND THE ARE APROPERLY SECURED.
CREW WAS MOVING3SOME CRIB BLOCKS OUT OF THE WAY IN 3RD LEFT BELT ENTRY WHEN THE STACK OF CRIB BLOCKS FELL OVER HITTING I NAME IN THE NOSE.
UNPLANNED ROOF 0ALL OCCURRED ABOVE ANCHORAGE POINT IN HEADGATE ENTRY 10' INBY X-CUT #26 IN 3RD LEFT LONGWALL SECTION MMU 005-0. FALL MEASURED 15'HIGH X 17'WIDE X 31'LONG. NO INJURIES OR IMPEDI MENT OCCURRED.A5L SAFETY PRECAUTIONS WERE TAKEN AND THE AREA PROPERLY SECURED.
UNPLANNED ROOF 0ALL GENERATED BY ROOF SQUEEZE OCCURRED IN TAILGATE ENTRY OF 3RD LEFT LONGWALL PANEL MMU0050 WHICH HASD IMPEDED PASSAGE THROUGH TAILGATE AREA ABOUT 30 FT OUTBY THE FACE THIS FLL ENCOMPASSES3AN AREA ABOUT 4X20 ALL SAFETY PRECAUTIONS WERE TAKEN AND AREA PROPERLY SECURED
CLEANING 3RD LE0T BELTLINE WHEN A RIB CAME DOWN STRIKING HIM ON LEFT LEG.
LIFTING A JACK 2N A WAGNER SCOOP WITH A PRY BAR THE BAR SLIPPED AND CAME DOWN ON PERSONS HAND SMASHING HIS FINGER
BOLTING ON FLET7HER CLOSED JAWS ON HIS HAND