Employee has been diagnosed with Occupational Pneumoconiosis, And has been terminated due to work force reduction on 3/25/2016.
Hunter Peerless Mine: 556 citaciones de la MSHA Coal
Hunter Peerless Mine tiene $520K en multas propuestas de MSHA y $0 pendientes en 45 expedientes impugnados, ademas del muestreo de salud y el registro completo de incidentes.
Seguir esta mina
Avísenme cuando se presente un nuevo incidente de la MSHA en Hunter Peerless Mine.
- Muertes
- 0
- Incidentes totales
- 40
- Años en registro
- 2009–2016
- Último incidente
- Jun 2016
ⓘ
Esta tasa son las citaciones registradas divididas entre las horas de inspección de la MSHA, por cada 100 horas. Refleja el esfuerzo de inspección, no el tamaño de la mina ni la producción.ⓘ
Una orden bajo la Sección 107(a) retira a los mineros de un área cuando un inspector detecta un peligro inminente. Cada orden se levanta una vez corregida la condición, por lo que esto cuenta las órdenes emitidas, no las que están en vigor ahora.Hunter Peerless Mine tiene $520K en multas propuestas de MSHA y $0 pendientes en 45 expedientes impugnados.
ⓘ
Las diferencias entre las multas propuestas y las pagadas reflejan tanto acuerdos y reducciones en conferencia como montos aun adeudados. Pendiente es el saldo que se debe actualmente.ⓘ
Las proporciones se calculan sobre las citaciones que llevan la codificación de gravedad y negligencia de la MSHA; una pequeña parte de los registros no está codificada.ⓘ
Impugnar una citación ante la Comisión Federal de Revisión de Seguridad y Salud Minera es un derecho legal. Estas cifras presentan los resultados públicos de ese proceso, según el archivo de Violaciones Impugnadas de MSHA.- Conciliadas 90 · 57%
- Quedaron como emitidas 64 · 41%
- Anuladas o retiradas 4 · 3%
ⓘ
Una citación Significativa y Sustancial cuenta como sobreviviente cuando la conciliación o la decisión del juez mantuvo la designación, o cuando la impugnación fue desestimada o quedó en rebeldía y la citación quedó como emitida. Las citaciones anuladas o retiradas, y las conciliaciones que quitaron la designación, cuentan en contra.ⓘ
Una reducción o desestimación ante la Comisión es un resultado legítimo de impugnar una multa propuesta. Las cifras son el monto propuesto y el monto confirmado en la decisión del expediente.| Expediente | Decisión | Juez | Año | Propuesta / confirmada |
|---|---|---|---|---|
| WEVA 2013-402 | Settlement | Gill | 2014 | $46K → $28K |
| WEVA 2009-1505 | Settlement | Rae | 2012 | $19K → $14K |
| WEVA 2015-0574 | Settlement | Feldman | 2016 | $18K → $9K |
| WEVA 2015-0832 | Settlement | Feldman | 2016 | $14K → $7K |
| WEVA 2012-357 | Settlement | Miller | 2012 | $12K → $9K |
| WEVA 2013-860 | Withdrawal | Gill | 2014 | $11K → $0 |
El muestreo de MSHA en Hunter Peerless Mine muestra que 95% de 1,122 muestras de polvo respirable de carbón cumplieron el estandar de 1.5 mg/m3.
ⓘ
Una muestra es una medición de cumplimiento en un momento dado, no un historial de exposición individual. Estas cifras describen registros de muestreo de MSHA y no establecen causalidad ni dosis personal.Polvo respirable de carbón
ⓘ
Las cifras de polvo respirable de carbón y sílice corresponden a instalaciones de carbón. El cumplimiento del polvo se mide frente a la norma actual de 1.5 mg/m3; se incluyen muestras anteriores a la norma de 2014, por lo que las tasas de cumplimiento son una senal historica aproximada.
Última medición: 2016-01-12, hace 10 años
ⓘ
Las cifras de polvo respirable de carbón y sílice corresponden a instalaciones de carbón. El cumplimiento del polvo se mide frente a la norma actual de 1.5 mg/m3; se incluyen muestras anteriores a la norma de 2014, por lo que las tasas de cumplimiento son una senal historica aproximada.ⓘ
El valor de concentración excesiva (ECV) es el umbral de aplicación por muestra de la propia MSHA, que incorpora la incertidumbre de medición; una muestra por encima de su ECV puede motivar una citación. El conteo cubre solo las muestras a las que MSHA asignó un ECV.- CONTINUOUS MINER OPERATOR649
- SHUTTLE CAR OPERATOR (STANDARD SIDE)137
- ROOF BOLTER (TWIN HEAD) (RETURN SIDE)60
Sílice (cuarzo)
Última medición: 2015-11-09, hace 10 años- CONTINUOUS MINER OPERATOR52
- ROOF BOLTER (TWIN HEAD) (RETURN SIDE)12
- BULLDOZER OPERATOR1
Ruido
ⓘ
La proporción cuenta las muestras de ruido cuya dosis medida superó el límite permisible de exposición de 90 dBA. Describe el lugar de trabajo muestreado, no lo que llegó al oído del minero: los programas de conservación de la audición y la protección auditiva usada durante el turno se registran por separado y no se reflejan aquí.
Última medición: 2016-01-20, hace 10 años
ⓘ
La proporción cuenta las muestras de ruido cuya dosis medida superó el límite permisible de exposición de 90 dBA. Describe el lugar de trabajo muestreado, no lo que llegó al oído del minero: los programas de conservación de la audición y la protección auditiva usada durante el turno se registran por separado y no se reflejan aquí.- SHUTTLE CAR OPERATOR (STANDARD SIDE)33
- CONTINUOUS MINER OPERATOR25
- ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)21
ⓘ
Una muestra es una medición de cumplimiento en un momento dado, no un historial de exposición individual. Estas cifras describen registros de muestreo de MSHA y no establecen causalidad ni dosis personal.ⓘ
Las cifras de polvo respirable de carbón y sílice corresponden a instalaciones de carbón. El cumplimiento del polvo se mide frente a la norma actual de 1.5 mg/m3; se incluyen muestras anteriores a la norma de 2014, por lo que las tasas de cumplimiento son una senal historica aproximada.| Año | dentro de 1.5 mg/m3 | muestras |
|---|---|---|
| 2016 | 100% | 1 |
| 2015 | 92% | 260 |
| 2014 | 95% | 160 |
| 2013 | 94% | 107 |
| 2012 | 93% | 114 |
| 2011 | 97% | 208 |
| 2010 | 98% | 195 |
| 2009 | 92% | 77 |
| Año | sílice prom. (%) | muestras |
|---|---|---|
| 2015 | 5.7 | 26 |
| 2014 | 5.1 | 17 |
| 2013 | 5.9 | 5 |
| 2012 | 3.9 | 5 |
| 2011 | 4.6 | 6 |
| 2010 | 3.9 | 9 |
| 2009 | 9.0 | 3 |
| Año | sobre el LPE | muestras |
|---|---|---|
| 2016 | 5% | 20 |
| 2015 | 0% | 15 |
| 2014 | 3% | 32 |
| 2013 | 0% | 9 |
| 2012 | 10% | 10 |
| 2011 | 0% | 3 |
| 2010 | 0% | 19 |
| 2009 | 6% | 18 |
Hunter Peerless Mine registró 17.49 casos de lesión reportables por cada 100 trabajadores a tiempo completo en 2016.
ⓘ
Esta tasa son los casos de lesión reportables por cada 100 trabajadores a tiempo completo por año, calculada como 200,000 por los casos dividido entre las horas-empleado reportadas por el operador a la MSHA. Los casos son lesiones que la MSHA clasificó en grado 01 a 07; se excluyen los eventos de solo accidente que no lesionaron a nadie, y también las lesiones de contratistas, cuyas horas no corresponden a una sola mina. Las tasas comienzan en el año 2000, cuando inicia el reporte trimestral de empleo, y se omiten por debajo de 20,000 horas en un año.| Año | tasa de casos totales | días perdidos | mortales |
|---|---|---|---|
| 2016 * | 17.49 | 0.00 | 0.000 |
| 2015 | 4.05 | 2.43 | 0.000 |
| 2014 | 5.73 | 2.29 | 0.000 |
| 2013 | 1.64 | 0.00 | 0.000 |
| 2012 | 3.22 | 0.00 | 0.000 |
| 2011 | 9.91 | 5.95 | 0.000 |
| 2010 | 6.71 | 4.02 | 0.000 |
| 2009 * | 2.66 | 0.00 | 0.000 |
- Elk Run Coal Company, LLC 2008 al presente
ⓘ
La producción de carbón se reporta trimestralmente y va con retraso respecto al periodo actual; los trimestres más recientes pueden estar incompletos.| Año | Empleados | Carbón producido (toneladas) |
|---|---|---|
| 2017 | 0 | |
| 2016 | 17 | 62,111 |
| 2015 | 101 | 840,641 |
| 2014 | 74 | 711,466 |
| 2013 | 51 | 363,390 |
| 2012 | 62 | 404,645 |
| 2011 | 85 | 794,869 |
| 2010 | 71 | 658,855 |
| 2009 | 36 | 260,705 |
| 2008 | 0 |
Hunter Peerless Mine se ubica en Boone County, West Virginia, donde la categoría minera del Censo representa el 10.1% del empleo del condado.
ⓘ
Las cifras del condado provienen de la Encuesta sobre la Comunidad Estadounidense de la Oficina del Censo de EE. UU., estimaciones quinquenales agrupadas, por lo que la edición de 2023 abarca de 2019 a 2023. La categoría del Censo es 'minería, explotación de canteras y extracción de petróleo y gas', que es más amplia que la jurisdicción de la MSHA e incluye a trabajadores de petróleo y gas que ninguna mina emplea. Estas cifras describen el condado circundante, no esta mina, y no son un factor en ningún incidente específico.ⓘ
Citaciones por millón de horas-empleado reportadas. Las tasas comienzan en el año 2000, cuando inician los datos trimestrales de empleo de la MSHA; los incidentes anteriores se cuentan pero no pueden ajustarse por tasa. Los trimestres con menos de 100,000 horas reportadas se muestran en gris: muy pocas horas para una tasa estable.| Trimestre | Horas trabajadas | Citaciones | S&S | Por 1M hrs |
|---|---|---|---|---|
| 2017 Q4 | 0 | 0 | 0 | |
| 2017 Q3 | 0 | 0 | 0 | |
| 2017 Q2 | 0 | 0 | 0 | |
| 2017 Q1 | 0 | 0 | 0 | |
| 2016 Q4 | 0 | 0 | 0 | |
| 2016 Q3 | 192 | 0 | 0 | 0.0 |
| 2016 Q2 | 481 | 0 | 0 | 0.0 |
| 2016 Q1 | 33,641 | 4 | 0 | 118.9 |
Mostrar 29 trimestres anteriores Ocultar trimestres anteriores
| Trimestre | Horas trabajadas | Citaciones | S&S | Por 1M hrs |
|---|---|---|---|---|
| 2015 Q4 | 67,574 | 11 | 2 | 162.8 |
| 2015 Q3 | 62,581 | 12 | 5 | 191.8 |
| 2015 Q2 | 59,809 | 17 | 10 | 284.2 |
| 2015 Q1 | 57,122 | 36 | 12 | 630.2 |
| 2014 Q4 | 52,157 | 37 | 7 | 709.4 |
| 2014 Q3 | 57,663 | 51 | 19 | 884.4 |
| 2014 Q2 | 33,030 | 23 | 8 | 696.3 |
| 2014 Q1 | 31,783 | 35 | 6 | 1101.2 |
| 2013 Q4 | 26,156 | 20 | 2 | 764.6 |
| 2013 Q3 | 28,728 | 10 | 2 | 348.1 |
| 2013 Q2 | 31,878 | 9 | 1 | 282.3 |
| 2013 Q1 | 34,894 | 5 | 0 | 143.3 |
| 2012 Q4 | 29,519 | 10 | 3 | 338.8 |
| 2012 Q3 | 30,174 | 18 | 5 | 596.5 |
| 2012 Q2 | 29,041 | 32 | 11 | 1101.9 |
| 2012 Q1 | 35,440 | 16 | 6 | 451.5 |
| 2011 Q4 | 46,917 | 23 | 9 | 490.2 |
| 2011 Q3 | 49,522 | 24 | 5 | 484.6 |
| 2011 Q2 | 51,627 | 21 | 10 | 406.8 |
| 2011 Q1 | 53,689 | 27 | 15 | 502.9 |
| 2010 Q4 | 47,638 | 24 | 10 | 503.8 |
| 2010 Q3 | 44,589 | 17 | 1 | 381.3 |
| 2010 Q2 | 30,330 | 22 | 11 | 725.4 |
| 2010 Q1 | 26,553 | 14 | 3 | 527.2 |
| 2009 Q4 | 25,661 | 9 | 1 | 350.7 |
| 2009 Q3 | 23,737 | 6 | 5 | 252.8 |
| 2009 Q2 | 21,744 | 2 | 0 | 92.0 |
| 2009 Q1 | 4,116 | 17 | 7 | 4130.2 |
| 2008 Q4 | 0 | 0 | 0 |
Incidentes reportables
40 en archivo2016 · 3 incidentes
Employee has been diagnosed with Occupational Pneumoconiosis. Employee was terminated due to work force reduction on March 25, 2016
Employee has been diagnosed with Pneumoconiosis on 11/30/2015. The safety department did not receive notification of diagnosis until 04-13-2016.
2015 · 5 incidentes
Employee has been diagnosed with Occupational Pneumoconiosis. The safety department was notified of his diagnosis on December 22, 2015. Employee retired December 2015.
Employee was setting up to take 1st lift out of block. Injured bent over to throw miner slack (cable) next to rib, when without warning, Rib Rolled off and struck him on the lower left leg and ankle pinning him between the miner and the rock. went to hospital and received X-rays RX.
Employee was traveling along the track on 4belt. When a piece of rock (measuring 4'X 2.5' X4") Fell from between the bolts and struck the Employee in the right shoulder knocking him off the ride. Injured went hospital and received a Diagnosis of Injury to the head, sprain of shoulder, contusion and a Concussion.
Employee has been diagnosed with occupational Pneumoconiosis. The safety department was informed of his diagnosis on August 5th 2015.
As Employee was picking up supplies his foot got twisted in a piece of plastic causing him to fall injuring his back. Employee was treated at CAMC General Division.
2014 · 6 incidentes
While walking across section Employee stepped in a hole causing his body to twist straining his back.
While Employee was pulling a hydraulic hose through the boom of the right continuous miner he felt a pain in his lower back. The Employee has been diagnosed with degenerative disc disease Degree 7 Occupational Illness.
While Employee was standing in #4 entry top brow fell off striking Employee in both legs. Employee was transported by EMS to CAMC General Division. (Resulted in fracture of lower right leg.)
An unintentional roof fall has occurred 7 breaks inby surface at spad 3939. The roof fall was approximately 100ft x 18ft x 5ft. There were no injuries reported and no equipment involved.
Employee has been diagnosed with Occupational Pneumoconiosis. The Safety Department received notification of this diagnosis on May 5, 2014. Employee has been off work since March 25, 2013.
Employee felt a pop in his right elbow as he was throwing a piece of curtain on the flat car. There was a piece of shuttle car cable tangled in the curtain. Employee was treated at MedExpress and x-rays indicated joint effusion with a possible fracture.
2013 · 4 incidentes
An unplanned roof fall occurred on the Stallion mains inby spad 3973 located in the face on #2 section. The falls specific location is in the last open crosscut from #3 entry to #7 entry. It starts from 1 break inby #3 entry and runs through 6 right crosscut.
An unplanned roof fall occurred at spad #1054, in #1 entry in the old works. Ventilation and passage of persons were not affected. Area was initially developed in 2010 and was supported by 6' resin bolts. Length of the fall was 40ft long X 18ft wide X 7ft high. Area will not be rehabilitated and all intersections have been timbered off. Federal and State agencies were notified.
Injured was setting supplemental roof support. He was holding the jack that a beam was resting on. Hand was resting on the tightening ear of the heintzman jack. While other employee was tightening his jack, the jack that injured was holding rolled, smashing his ring finger (no ring on).
Roof Fall in the #1 entry (return) along #11 belt measuring 100'long by 19'wide and 6'- 7' high. Area was bolted with 48" resin bolts in conjunction with 72" torque tension bolts. All approaches have been timbered off and no plans at this time to clean up.
2012 · 5 incidentes
An unplanned roof fall occurred at spad #936, in #3 entry up in the old works. Ventilation and passage of persons were not affected. Area was initially developed in 2010 and was supported by 6 foot torque tensions. The length of the fall was 20ft x 20ft x 8ft high. Area will not be rehabilitated and all intersections have been timbered off. Federal and State agencies were notified.
Walking across the section, injured tripped over a cable and caught himself. In doing so he put pressure onto his left shoulder and it became dislocated. Doctors put it in place and gave him 3-5 days of light duty.**Restrictions did not prevent the employee from doing ALL of his regular duties**
A unplanned roof fall occurred at Spad#1448 in the #6 Entry on the Old#2 Left Panel. The size of the fall was 80'L. X 18'W. X 3-5' H. Passage of person was not affected, ventilation was affected. Area was developed on Jan. 2011 and was originally supported resin roof bolts. Area has been dangered off, and will not be rehabilitated. Federal and State Agencies notified immediately.
Two electricians were lifting a small power box onto the top of a kva box on the yard at the mine site. The small box shifted and caught the index finger of the left hand of one man. He received a laceration that required four stitches. He was wearing leather gloves without metacarpal protection.
A unplanned roof fall occurred in the 1st panel in the #7 entry at spad 1686 in the return air course. Fall is approx. 5,700' from nearest active section. Fall will not be rehab. Passage of person and ventilation was not affected. Fall meas. 160'X20'X4' area was initially supported with 5' torque tension roof bolts. Federal and State agencies were notified immediately.
2011 · 10 incidentes
Employee was splicing a shuttle car cable. He laid the cable on his thigh and began cutting, using a utility knife. The knife slipped and cut his thigh. The laceration required three stitches. He returned to work on his next shift.
Employee was using a chain hoist to raise the top conveyor belt to change a top of piece of belt structure. The hoist came loose and fell onto his right hand near the thumb. His hand was laying on the belt rail at the time. He received a fracture. He was not wearing his metacarpal gloves. He retuned to work on his next shift.
Miner operator and two shuttle car operators were hanging the miner cable. The miner operator was on his knees and over-stretched while lifting the cable. He complained of his back hurting. He was transported to CAMC where he was diagnosed with a muscle strain in his back. He was given two days off.
EE was using torches to remove the cable stand off the right continuous miner. While cutting, hot slag went into his left ear. He continued working until Aug.28,2011. He sought medical attention on the third day after becoming light headed. Doctors said he had burned his eardrum and the ear was infected. He is off work receiving treatment.
EE was riding mantrip with the crew to #2 section. He was riding with the operator instead of the passenger compartment. The mantrip was not over crowded. EE said he was just riding there. He reached for his tobacco and his head hit the mine roof causing neck pain. He was released from CAMC hospital and told to remain off work a couple of days to rest his neck.
Employee was taking down MRS cables. The cables had been hung with nylon hangers with two hooks. He removed one hook. The hanger had been wrapped around the cable several times. The weight of the cable caused the hanger to spin free. The cable hook hit his nose. He had six stitches to the left nostril. He missed no work.
Power knocked on CM (JM6432). Operator and scoop man were tightening the waterline swivel near a damaged place in the cable. Someone reset the circuit breaker and cable went phase to phase creating an arc. The scoop operator may have received. a shock when the arc occurred as he stumbled away from the cable. EE was kept in the hospital two days for observation.
While replacing the rub rail on the miner, electrician felt pain in his back. Tests were negative and he was released from the hospital emergency room. He missed work and went back to the doctor. He was excused from work for three days.
Electrician was at the section power center drilling a larger hole in a ring terminal. He was holding the terminal with his left hand and the drill in the right. The drill bit caught his glove and lacerated his left thumb. He continued working and later sought medical treatment. The cut required 7 stitches. The safety department did not receive the report until 2/15/11.
Employee was taking a left-handed lift on the #2 pillar section. He backed the miner out to check a leaking boom swing hose. He and a miner helper were on the offside of the miner checking the leak when a rib rolled and struck employee on his lower left leg. He received multiple fractures to the left foot. *Doctors had to amputate below knee.
2010 · 6 incidentes
Loading structure into scoop bucket, EE told the operator to pull ram in to tighten pull chain. EE had his index finger in back of ram. He had swelling to his finger but x-rays revealed no injury. He stayed off for a follow up with specialist and no injury was found. No therapy or treatment has been scheduled. Due to soreness, he remains off work.
Employee was walking to the mantrip when he tripped and fell. A pick hammer he was carrying pierced his left hand between his thumb and index finger. He drove to CAMC and received six stitches. He returned to work on his next shift.
EE was unloading a pallet of roof "pizza" pans with the forklift. He dropped the load, breaking the pallet and scattering the pans. He said he was throwing a temper tantrum and slinging the pans to theside. One of the pans cut his left middle, ring and small finger. He went to Boone Memorial and rec. 2 stitches on the middle finger.
Employee was walking around the mantrip which was parked at the end of the track in a spur for the new section. He was going for electrical tape. He heard a flyboard crack and then rock knocked his hardhat off. The rock hit his left shoulder and then rolled down to the back of his leg. His leg and foot were bruised. He was instructed to keep it elevated for three days.
EE was on the Brookville Mantrip heading underground when he felt he was having a heart attack. He was transported to Raleigh General Hospital where test confirmed he had a heart attack. His Dr advised him that he is not able to perform physical labor and we are currently trying to place him in a mine office or similar position.
Crew was spot bolting outby face in #2 entry. EE was operating the helper side of a Fletcher RRII. He swung the drill out to spot a bolt between the outside bolt and the rib, when loose rock fell onto his right foot. X-rays revealed fractures to ankle. Surgery on 3/28/10. A plate and screws were inserted. Rock measrued 5"X12"WX30"L. Wearing tiger-tip metatarsal boots.
2009 · 1 incidente
Member was working on a brookville pump motor coupling. He was in the process of removing a coupling off of pump shaft by using a chisel and hammer, upon striking the chisel with the hammer, chisel bounced and struck member on the left cheek. Member finished shift and went to a medical facility and received 3 stitches.