EE was on 2700 station. EE's partner went to find a chain, upon return EE was on the ground having a seizure. A call for help was made for a medical emergency; the EE had multiple seizures. EE could not remember what happened. Medical testing concluded EE must have struck EE's head with triggered the seizures. That diagnosis was made on 10/17/2026.
En todo el registro
- Incidentes totales
- 741.923
- De los cuales mortales
- 3.130
- Años en el registro
- 1983–2026
- Clasificaciones
- 20
8 registros en total
Mostrando los 8Notificarme sobre esta búsqueda
Envíenme un correo cuando un nuevo incidente coincida con estos filtros. Un correo de confirmación; deje de recibir estas alertas cuando quiera.
Employee was in the process of cutting vent bag with a razor knife and it slipped striking employee on opposite left hand.
During a winter storm, we lost power to the site causing us to lose hoisting capabilities. Seven employees were downshaft at the time.
During a winter storm, a tree fell onto the power lines coming into the mine. This caused a power outage which made the hoist inoperable.
EE was installing air header onto existing HDPE pipe valve. EE tightened the vic between the valve and header. EE realized the header needed to be rotated so EE used the impact and started to loosen the bolt. EE inadvertently loosened the bolt on the charged side of the valve causing the header to break free from the vic.
EE was swamping on the back of the track lowboy that was loaded with an electrical cabinet. The cabinet came in contact with the lockbox for the portal gate causing the lowboy to come to a sudden stop. The stop caused the employee to come in contact with the electrical cabinet.
The electric motor for the pump on the 1700 level lost one leg of the 3 phases. This caused the remaining two legs to heat up because they were drawing more amperage. The varnish on the coils and insulation started to smoke as a result of the motor heating up.
A hydraulic hose fitting failed on the Chippy hoist braking system. The hydraulic braking system lost pressure and the brakes set. The hoist was not operational.