Setting feeder on belt move pinched thumb between two crib blocks
En todo el registro
- Incidentes totales
- 740,335
- De los cuales mortales
- 3,118
- Años en el registro
- 1983–2026
- Clasificaciones
- 20
Notifícame sobre esta búsqueda
Envíame un correo cuando un nuevo incidente coincida con estos filtros. Un correo de confirmación; cancela la suscripción cuando quieras.
95 registros en total
Mostrando 50 de 95Setting feeder on belt move pinched EE's thumb in between 2 crib blocks
Pulling a bearing off feeder shaft because bearing was down while pulling it off chain, slipped off bearing, striking them on the right wrist.
Roof had a slickened side to it plus it fell above anchorage.
Roof fall occurred on belt line due to slicken sided undetected roof. Top was also bolted with approved 4' bolts.
A roof fall occurred on the primary escapeway. No one or equipment was involved.
The victim was loading rock dust when they threw a bag of dust. They hurt their right shoulder.
While removing drill steel from the drilled hole, a piece fell out striking employee on the right hand.
After removing rub rail pin, the rub rail fell on victim's left foot.
The transformer in a belt power center became grounded and caught fire.
Slick sided slip (horse back) fell on primary escapeway. Damaged high voltage cable
The fall occurred in intersection due to high angle slips
While operating shuttle car the victim ran thru a pothole causing the car to bounce and felt pain in his lower back.
A roof fall was discovered int he No. 6 of the second left pillared panel. The fall measured 80'l x 20'w x 7'h. The fall was located 30' inby station #1204.
A roof fall was discovered in No. 2 return entry 300' outby the face area of the No. 1 South. The fall measured 8' H x 20' W x 85' L. Ventilation and travel was not affected.
The operator of the fletcher roof bolter dropped the head of the machine on his knee.
The injured man stated that while unloading timbers from a scoop, he felt a sharp pain in his abdomen.
A roof fall occured approx. 1600' outby the 001 section fall measured 65Lx7'Hx20'W. The fall was located 60' outby spad 1069 in the No. 3 neutral entry.
A ROOF FALL OCCURRED APPROX. 1200' OUTBY THE 001 SECTION. IT MEASURED 80' LONG X 20' WIDE X 8' HIGH. THE LOCATION WAS IN THE INTAKE JUST OUTBY SURVEY STATION #1056 IN THE #6 ENTRY.
A roof fall was discovered in the return (no. 1 entry). The fall 18' in width, 40' in length and 7' in height. It was located 400' outby face area at spad 1082.
A ROOF FALL WAS DISCOVERED IN THE RETURN (NO. 1 ENTRY) OF THE 001 SECTION. IT BEGAN 80' INBY SPAD NO. 1024 AND EXTENDED 70' UP TO THE NO. 1 ENTRY. THE FALL WAS 20' WIDE AND APPROXIMATELY 7' HIGH.
A ROOF FALL WAS DISCOVERED IN THE INTERSECTION OF NO.3 HEADING ON THE 001 SECTION ONE CROSSCUT OUTBY FACE. SPAD NO. 916.
THE VICTIM WAS TRAVELING UNDER THE HUNG MINER CABLE WHEN HIS SHUTTLE CAR CAME INTO CONTACT WITH CABLE TEARING IT DOWN AND CUTTING HIM BEHIND THE LEFT EAR.
ROOF FALL FOUND DVRING REHABILITATION OF THE MINE.
EE WAS INJURED WHILE HELPING TO MOVE A DISTRIBUTION BOX FROM THE SHOP. WHILE ATTEMPTING TO LEVEL THE UNIT ON A FLOOR JACK, IT SLIPPED OFF. THE EDGE OF THE UNIT STRUCK HIS RIGHT FOOT BEHIND THE HARD TOE RESULTING IN 4 FRACTURED TOES. ON 9/17/00 THE FOURTH TOE AND THE SMALL TOE WERE AMPUTATED DUE TO THE INJURY.
WHILE DRILLING STARTER HOLE WITH STARTER STEEL 24" LONG. HAD FINISHED DRILLING HOLE 24" DEEP. HE HAD LOWERED BOOM SOME. HE PUT HIS HAND ON STEEL. (NOT ROTATING) TO LOWER STEEL OUT OF HOLE. HE RAISED BOOM BY MISTAKE AND CAUGHT RT HAND 1ST FINGER FROM THUMB, BETWEEN ROOF AND STEEL. PINCHING FINGER.
EMPLOYEE HURT HIS LOWER BACK WHILE OPERATING MACHINE. AFTER HANGING THE MINER CABLE HE SAT DOWN IN THE MINER DECK AND FELT A PAIN IN HIS LOWER BACK.
ROOF BOLTER OPERATOR WHILE INSTALLING 42" FULLY GROUTED BOLT CAUGHT HIS FINGER BETWEEN THE BOLT AND THE HEAD OF THE MACHINE.
EMPLOYEE WAS OPERATING ROOF BOLTER IN FACE ON #3 ENTRY ON THE 001 SECTION WHEN THE ATRS SYSTEM ON THE ROOF BOLTER ROLLED DOWN CATCHING HIM AGAINST FRAME OF ROOF BOLTER RESULTING IN DEATH.
ELECTRICIAN WAS INSTALLING A 800 AMP MINER BREAKER AFTER SUPPLYING POWER (600 VOLTS) TO THE TOP OF THE BREAKER HE WAS MAKING A CHECK ON THE MONITOR CIRCUIT. WHEN HE PUT THE BREAKER IN THE TO P OF OF IT SHORT CIRCUITED CAUSING AN ELECTRICAL FIRE.
THE INJURED MAN WAS DROPPING THE TRAILING CABLE FROM THE HANGNERS WHEN THE OPERATOR ACTIVATED THE CABLE REEL TAKE UP. THE CABLE STRUCK EE ON HI S LOWER LIP, RESULTING IN A BROKEN TOOTH.
OPERATOR INSTALLED 1ST BOLT IN THE CUT. HE HAD REPOSITIONED BOLTER SO THE OTHER OPR COULD PUT UP ADDITIONAL BOLT. HE WAS WAITING ON THE OTHER OPR TO FINISH HIS BOLT. SITTING ON RIB 3 RAIL OF B OLTS OUTBY LAST ROW WHEN A ROCK & COAL BROW FELL HITTING HIM ON LEFT KNEE. ROCK & COAL 18" TRIANGLE. 2" THICK. (#5 RT CUT THROUGH TO #6. 140' INBY SPAD #136.)
ROOF FALL OCCURRED APPROX. 850 FEET FROM SURFACE AND 5000 FT OUTBY WORKING SECTION. FALL WAS 40' LONG 20' WIDE 4 TO 6' THICK. ROOF WAS SHALE. THERE WAS A SLIP IN FALL AREA. THERE ARE NO PLANS OF CLEANING UP AT THIS TIME. ALL APPROACHES HAVEBEEN TIMBERED AND DANGERED OFF.
EE WAS HANGING A LINE CURTAIN HE WAS PULLING UP EXCESS CURTAIN WHEN HE FELT A PAIN IN HIS LOWER BACK.
EE WAS INJURED WHILE DRILLING ANCHOR HOLES FOR A TAILPIECE IN THE MINE FLOOR. THE GLOVE ON HIS RIGHT HAND CAME INTO CONTACT WITH THE ROTATING AUGER STEEL RESULTING IN A BROKEN FINGER ON HIS RI GHT HAND.
ROOF FALL OCCURRED APPROX. 600 FT UNDERGROUND ON THE BELT LINE. IT WAS A SLIP APPROX. 20' WIDE 40' LONG 6' HIGH. IT WAS IN AREA WHERE SANDSTONE CHANGED OVER TO SHALE. THE MINE IS 4,000 FT DEEP
ROOF FALL OCCURED DURING AN IDLE SHIFT IN THE FACE AREA. NO 4 ENTRY INTERSECTION IT WAS A HORSEBACK APPROX 2O'LONG 18'WIDE AND 6' THICK. THE CRACK WAS NOT DETECTED DURING DEVELOPMENT. THERE WA S NO EQUIPMENT OR PERSONNEL INVOLVED.
WHILE UNLOADING A BUNDLE OF ROOF BOLTS FROM A FLAT BED TRUCK THE INJURED MAN LOST HIS FOOTING ON A SLIPPERY METAL SURFACE. HE FELL FROM THE TRUCK TO THE GROUND. THE FALL WAS RESULT OF FOUR FRA CTURED RIBS.
AREA WAS MINED ON 5/20/97. SLIP WAS SEEN INAREA WHEN MINED. LONGER BOLTS WERE USED AND AREA WAS CRIBBED. FALL WAS LOCATED AT SPAD 55 1800 FT FROM FACE AREA. FALL IS 70'L, 20'W APX 5'THICK.
MAKING BELT MOVE,EMPLOYEE WAS LOCKING BELT DOG ON STEEL ROPE WITH A HAMMER. SMALL PIECE OF METAL CHIPPED OFF AND HIT HIM ABOVE LEFT EYE. EMBEDDING IN SKIN.
INTERSECTION AT SPAD #279. SLIP WAS DETECTED ON DEVELOPMENT OF ENTRY 4-9-97. 6'POINT ANCHOR WERE INSTALLED DURING DEVELOPMENT. THE WORKING FACES ARE 1100 FT FROM FALL AREA. NO DAMAGE OR AIR IN TERRUPTION WAS CAUSED BY FALL. FALL WILL NOT BE CLEANED UP AT THIS TIME. ACCESS TO FALL WILL BE CRIBBED OFF.
VICTIM WAS IN PROCESS OF PLACING TURP ON THE COAL TRACK WHEN BRACE COME IN CONTRACT WITH 1 PHASE OF 12470 VOLTS HIGH VOLTAGE LINE.
GETTING 2 LIFT ON RT. HAND CUT IN #7 ENTRY. TOP FELL IN GOB AREA COMING INTO #7 ENTRY. MINER WAS MOVING OUT OF THE CUT. TOP CAUGHT 4' OF RIPPER HEAD, FOULING MINING. FALSE BOTTOM BROKE UP UNDE R MINING. USED JUMPER RAIL UNDER CATS TO GET MINING OUT. MINING WAS OUT AT 5:00 P.M.
EMP WAS SPOT BOLTING THE ROOF. PIECE OF ROCK 6" THICK BY 2" WIDE, 6.8"LONG, FELL WHEN THE PINNERSTEEL STARTED IN THE ROOF CATCHING HIS FINGER ONTHE HEAD OF THE BOLTING MACHINE.
CONTINUOUS MINER WAS CAUGHTIN A ROOF-PILLAR FALL 200' OUTBY SPAD 776. THE FALL CAOVERED NEARLY 2/3 OF THE MACHINE. THE MACHINE WAS RECOVERED 22 HR. LATER.
CONTINUOUS MINER WAS CAUGHT IN A PILLAR FALL. THE FALL COVERED APPROX. 1/3 OF THE ?. THIS HAPPENED 60' INBY SPAD # 766. MACHINE WAS CAUGHT APPROX. 5 HOURS.
WAS INJURED WHILE OPENING ROCK CHUTE DOOR ON STACKER BELT. WHILE OPENING DOOR THE OTHER DOOR FELL CATCHING FINGER INBETWEEN THE TWO DOORS.
MINER HELPER STRAINED LOWER BACK WHILE LIFTING MINER CABLE.
THE MAN WAS INJURED WHEN HE SLIPPED WHILE ATTEMTING TO BEND A FOUR FOOT ROOF BOLT.
INJURED MAN WAS HELPING INSTALL A POT ON A CONTINUOUS MINER. IT WAS DUTING THIS PROCEDURE THAT HE STRAINED HIS BACK.