July 10, 1991 at 12:45 PM
Continental Mine · Montana Resources, LLC · Silver Bow County, MT
Investigator narrative
THE EMPLOYEE, AN ELECTRICIAN, WAS CALLED TO THE MINE TO REPOWER 793 DRILL FROM THE "IRON HORSE" 4160 VOLT POWER DISTRIBUTION CENTER BY THE MINE FOREMAN. #4 CUBICLE WOULD NOT "RACK IN" THUS POW ER WAS TO BE CONNECTED FROM #1 CUBICLE. #1 HAD A BLOWN FUSE THUS THE VICTIM ELECTED TO PULL A FUSE FROM #4 TO IN #1. RETURNING TO #4, THE VICTIM OPENED THE DOOR AND GRABBED FOR A FUSE. THE FU
Record details
Classification
ELECTRICAL
Accident type
Contact with electrical current
Activity at time
Electrical Maintenance
Subunit / location
STRIP, QUARY, OPEN PIT
Source of injury
ELECTRICAL APPARATUS,NEC
Nature of injury
ELECT SHOCK,ELECTROCUTION
Body part affected
BODY SYSTEMS
Total mining experience
28 years
Experience at this mine
5 years
Experience in this job
20 years
Mine type
Surface
Sector
Metal/Non-Metal
Similar incidents in MSHA records · same classification: ELECTRICAL
  • September 13, 2025 · Tower Rock Stone Company · MO · Electrician

    Miner was on first floor of "New Office" working on a ladder changing a light. Miners co-worker went to basement to retrieve another new light. Co-worker heard a thump and a bang on the ceiling. Co-worker found miner sitting slumped on the floor unresponsive. Started CPR, called 911, deployed AED but the miner could…

  • July 26, 2025 · Stillwater Mining Company · MT · Electrician

    The employee was performing routine preventative maintenance on a transformer when EE was fatally electrocuted.

  • August 9, 2024 · Buzzi Unicem USA · TX · Master Mechanic

    Arc flash event involving electrical equipment that resulted in burns to the employee's arms and torso as well as electrical equipment damage. The employee was injured and hospitalized after the incident but, passed away in the hospital on 08/22/2024.