Superintendent fatality
POWER (480 V) TO THE SHUTTLE CAR LOCATED AT THE 7 SHAFT PUMP PROJECT AREA WAS INTERRUPTED WHEN THE GROUND FAULT UNIT TRIPPED. THE CIRCUIT WAS DE-ENERGIZED AND THE TRAILING CABLE, WHICH WAS PAR TIALLY COVERED WITH WATER, WAS HUNG ALONG THE RIB IN ORDER TO DUMP MATERIAL IN RUTS CREATED BY MOBILE EQUIPMENT. POWER WAS RESTORED TO THE SHUTTLE CAR. THE VICTIM CONTACTED A DAMAGED SPOT ON
- Classification
- ELECTRICAL
- Accident type
- Contact with electrical current
- Activity at time
- Move Power Cable
- Subunit / location
- UNDERGROUND
- Underground location
- INBY PERMANENT SUPPORT
- Source of injury
- CONDCTR,ELCT,CBL,TROL POL
- Nature of injury
- ELECT SHOCK,ELECTROCUTION
- Body part affected
- BODY SYSTEMS
- Mine type
- Underground
- Sector
- Metal/Non-Metal
-
September 13, 2025 · Tower Rock Stone Company · MO · Electrician
Miner was on first floor of "New Office" working on a ladder changing a light. Miners co-worker went to basement to retrieve another new light. Co-worker heard a thump and a bang on the ceiling. Co-worker found miner sitting slumped on the floor unresponsive. Started CPR, called 911, deployed AED but the miner could…
-
July 26, 2025 · Stillwater Mining Company · MT · Electrician
The employee was performing routine preventative maintenance on a transformer when EE was fatally electrocuted.
-
August 9, 2024 · Buzzi Unicem USA · TX · Master Mechanic
Arc flash event involving electrical equipment that resulted in burns to the employee's arms and torso as well as electrical equipment damage. The employee was injured and hospitalized after the incident but, passed away in the hospital on 08/22/2024.