Mining Incidents

Knife River Construction Vernalis PlantMetal/Nonmetal

TRACY, San Joaquin County, CA · Active
MSHA Mine ID: 0405459
Fatalities
1
Total incidents
5
Years on record
2006–2023
Latest incident
Sep 2023

Fatalities at this mine

1 recorded
Caught in, under or between a moving and a stationary object

Knife River miners were replacing a screen. Our sales representative was on site. He was on site to provide technical assistance. He was struck in the head by the feeder box. EMS was notified and responded. A Knife River operator notified MSHA within 15 minutes. Injured person was taken to the hospital where he then passed away.

Reportable incidents

4 on file (excluding fatalities above)

2023 · 1 incident

Caught in, under or between a moving and a stationary object

Replacing a coarse material washer (CMW) located inside a tub the employee was pinned between the CMW and a material chute above the tub. the employee was pinned for approximately 30 seconds, briefly lost consciousness and suffered bruising to the ribs and chest.

2020 · 1 incident

Struck by... (Not Elsewhere Classified)

Laceration to the non-dominant hand, Right ring finger approx 1/2 inch in length. 7 stitches. Employee was unbolting a screen deck with a leather glove and battery operated impact tool. As EE was removing the bolt, the bolt spun and it had a small metal bur on the end. Which spun and cut the glove and the employee's finger on the distal digit (tip) of finger.

2007 · 1 incident

Caught in, under or between a moving and a stationary object

Two men were replacing bottom seal ring on cone crusher. The seal ring slipped off retaining lip while installing bolts mashing man's left hand 2nd finger between ring and main shaft.

2006 · 1 incident

(Not Elsewhere Classified)

Reportable hearing loss 1-16-06 had sinus infection after repeted doctor visits, M.R.I, Cat Scan, Full audio Tests, on 6-28-06 doctor was unable to rule out noise induced hearing loss, damage may have been as mutch as 10 year ago. hearing loss in both ears in exess of 10 db