Mining Incidents
Fatality · MSHA Record #220203300010

Maintenance Man, Mechanic, Repair/Serviceman, Boilermaker, Fueler, Tire Tech, Field Service Tech

November 23, 2020 at 1:13 PM
Houston Plant · Facility · Metal/Nonmetal
Harris County, TX
ClassificationELECTRICAL
TypeContact with electrical current
Investigator narrative
Contributing Factors: (1)Energized equipment. (2)EE failure to follow company LO/TO procedures. (3)Outer wire jacket showed signs of heating & cooling. (4)EE grabbed the live ""C"" phase wire.
Record details
Activity at time of incident
Electrical Maintenance
Subunit / location
MILL OPERATION/PREPARATION PLANT
Accident type
Contact with electrical current
Source of injury
ELECTRICAL APPARATUS,(Not Elsewhere Classified)
Nature of injury
ELECT SHOCK,ELECTROCUTION
Total mining experience
1.17 years
Experience at this mine
1.17 years
Experience in this job
1.17 years
Degree of injury
FATALITY