Mining Incidents
Fatality · MSHA Record #220112150040

Superintendent fatality at Superior Cleaning Plant (Superior Processing, Inc.), WV, July 27, 2011

at 8:40 PM

On July 27, 2011, a superintendent was fatally injured in an electrical accident at Superior Cleaning Plant (Superior Processing, Inc.), WV.

Superior Cleaning Plant · Facility · Coal
Contractor on site: LVQ
Mcdowell County, WV
Classification ELECTRICAL
Type Contact with electrical current

Watch this mine

Email me when a new MSHA incident is filed at Superior Cleaning Plant.

Investigator narrative
Employee was welding two pipes together at an elevated location when an apparent electrocution happened. He was working in a confined location and was probably wet with sweat.
Record details
Activity at time of incident
Welding Or Cutting
Subunit / location
MILL OPERATION/PREPARATION PLANT
Accident type
Contact with electrical current
Source of injury
MACHINE,(Not Elsewhere Classified)-WELDR,OFC MAC
Nature of injury
ELECT SHOCK,ELECTROCUTION
Body part affected
BODY SYSTEMS
Total mining experience
22 years
Experience at this mine
1 year
Experience in this job
22 years
Degree of injury
FATALITY

Related fatalities

Same classification

Same year

Verify on MSHA

Every record on this page mirrors what MSHA publishes under its Open Government Data program, refreshed weekly. MSHA does not publish per-accident URLs (the Accidents data is distributed as a single bulk file), so this is how to retrieve the source for the specific record below:

Source: US Mine Safety and Health Administration (MSHA) · Document 220112150040 · Mine ID 4603303 Trainer view →