FAULT IN ROOF CAUSED ROOF FALL APPROX 140\ OUTBY SPAD #3884 IN #1 ENTRY, THIS FALL IS APPROX 4\ THICK, 18\ WIDE, AND 40\ LONG. THIS AREA HAD SHOWN SIGNS OF WEAKING AND ADDITIONAL SUPPORT SUCH CRIBS HAD BEEN SET, THIS AREA HAS BEEN DANGERED OFF
No 7 Mine Coal
Watch this mine
Email me when a new MSHA incident is filed at No 7 Mine.
- Fatalities
- 0
- Total incidents
- 5
- Years on record
- 1983–1984
- Latest incident
- Aug 1984
Reportable incidents
5 on file1984 · 1 incident
1983 · 4 incidents
WHILE BOLTING TOP PIECE OF DRAW SLATE FELL CATCHING LEFT HAND AGAINST HEAD OF ROOF BOLTING MACHINE
ENTRIES DRIVEN THRU A FAULT AREA WITH WEAK IMMEDIATE ROOF THE TOP SHIFTED CAUSING STRATA TO SEPARATE SUBSEQUENTLY CAUSING A FALL IN THE INTERSECTION
WITH ALREADY WEAK STRATA FOR IMMEDIATE ROOF -TOP SHIFTED CAUSING CRACKS AND ROOF FALL.STEPS HAD BEEN TAKEN TO SECURE TOP ..RESIN BOLTING AND CRIBS INSTALLED.
WHILE OPERATING ROOF BOLTER STEEL BECAME LODGED IN TOP WHILE TRYING TO FREE STEEL IT CAME LOOSE FALLING AND STRIKING LEFT HAND BROKEN BONE TO THUMB AND F OREFINGER