AN UNINTENTIONAL ROOF FALL OCCURRED STARTING IN THE 4 ENTRY EXTENDING TO 5 ENTRY SPAD 706 IN THE 4 ENTRY. THE FALL WAS ESTIMATED TO BE APPROX. 6' H X 20' W X 60-70' L. AREA HAD BEEN BOLTED WIT H 4' RESIN BOLTS WITH ADDITIONAL SUPPORT CONSISTTING OF 9' COMBINATION BOLTS. NO INJURES, 1 MBC 2 BRIDGE WAS CAUGHT VENTILATION WAS NOT INTERRUPTED.
13a-H4 Coal
MSHA record for 13a-H4 (mine ID 1517885). Fatalities, non-fatal incidents grouped by year, current operator and controller, and mine context.
Watch this mine
Email me when a new MSHA incident is filed at 13a-H4.
- Fatalities
- 0
- Total incidents
- 9
- Years on record
- 1997
- Latest incident
- Aug 1997
Reportable incidents
9 on file1997 · 9 incidents
EE WAS TRAVELING ALONGSIDE OF MOBIL BRIDGE WHEN EE SLIPPED/TRIPPED FALLING STRIKING HIS RIGHT SHOULDER ON MOBILE BRIDGE. EE SUSTAINED DISLOCATION TO RIGHT SHOULDER.
AN UNINTENTIONAL ROOF FALL OCCURRED IN THE #1 ENTR AT #1 BREAK, 1 BREAK OUTBY SPAD #491. THE FLAL WAS ESTIMATED TO BE 5-6'H 18'-20'W,20'-25'L. AREA HAD BEEN BOLTED WITH A 4' FULLY GROUTED RE SIN BOLTS, WITH ADDITIONAL SUPPORT CONSISTING OF 9'COMBINATION BOLTS. NO INJURIES, NO EQUIPMENT WAS CAUGHT VENTILATION WAS NOT INTERRUPTED. FALL WILL BE CLEANED UP.
AN UNINTENTIONAL ROOF FALL OCCURRED IN THE #7 ENTRY AT #34 BREAK, 1 BREAK INBY SPAD #443. THE FALL WAS ESTIMATED TO BE 6-9' HIGH, 25' WIDE, 25' LONG. AREA HAD BEEN BOLTED WITH 4' FULLY GROUTED RESIN BOLTS WITH ADDITIONAL SUPPORT CONSISTING OF 9' COMBINATION BOLTS. NO INJURIES, NO EQUIPMENT WAS CAUGHT, VENTILATION WAS NOT INTERRUPTED. FALL WILL NOT BE CLEANED UP.
AN UNINTENTIONAL ROOF FALL OCCURRED IN THE #6 ENTRY AT #35 BREAK 1 BREAK INBY SPAD #442. THE FALL WAS ESTIMATED TO BE 6-9' HIGH, 25' WIDE, 25' LONG. AREA HAD BEEN SUPPORTED WITH 4' FULLY GROUT ED RESIN BOLTS WITH ADDITIONAL SUPPORT CONSISTING OF 9' COMBINATION BOLTS. NO INJURIES, NO EQUIPMENT WAS CAUGHT, VENTILATION WAS NOT INTERRUPTED.
AN UNINTENTIONAL ROOF FALL OCCURRED IN THE #5 ENTRY AT #21, 1 BREAK INBY SPAD #364. THE FALL WAS ESTIMATED TO BE 6'-9' HIGH, 25' WIDE, 25' LONG. AREA HAD BEEN SUPPORTED WITH 4' FULLY GROUTED, RESIN BOLTS WITH ADDITIONAL SUPPORT CONSISTING OF 9' COMBINATION BOLTS. NO INJURIES, NO EQUIPMENT WAS CAUGHT, VENTILATION WAS NOT INTERRUPTED. FALL WILL NOT BE CLEANED UP.
AN UNINTENTIONAL ROOF FALL OCCURRED IN TEH #7 ENTRY AT #20 BREAK, 1 BREAK INBY SPAD #366. THE FALL WAS ESTIMATED TO BE 6'-9' HIGH, 25' WIDE, 25' LONG. AREA HAD BEEN SUPPORTED WITH 4' FULLY GRO UTED RESIN BOLTS WITH ADDITIONAL SUPP0RT CONSISTING OF 9' COMBINATION BOLTS. NO INJURIES, NO EQUIPMENT WAS CAUGHT. VENTILATION WAS NO INTERRUPTED. FALL WILL NOT BE CLEANED UP.
EE WAS HELPING INSTALL 8" IBEAMS WHLE IN THE PROCESS OF INSTALLING ONE OF THE BEAMS, BEAM SLIPPED/DISLODGED STRIKING EE ON THE BACK OF NECK KNOCKING HIM TO MINE FLOOR. INITAL DIAGNOISED AS SPR AIN AND BRUISE TO NECK, AFTER CT SCAN EE WAS DIAGNOISED WITH HAVING COMPRESSION FRACTURE TO THE T11 & T12 VERTRABRAE
AN UNINTENTIONAL ROOF FALL OCCURRED IN 13A-H4 MINE IN #4 ENTRY(BELT & TRACK) 10'-15' INBY SPAD #9. FALL WAS APPROX. 50'-60'LONG, 6'-8'HIGH, 18'-20'WIDE. AREA HAD BEEN SUPPORTED WITH 5' FULLY G ROUTED RESIN BOLTS WITH SUPPLEMENTAL SUPPORT CONSISTING OF 9' COMBINATION BOLTS. NO INJURIES, BELT LINE WAS CAUGHT, VENTILATION WAS NOT INTERRUPTED. *FALL WILL BE CLEANED UP.