AN UNINTENTIONAL ROOF FALL OCCURRED 160'INBY SPAD #701 IN THE #5 ENTRY. SIZE OF FALL WAS APPROX 4'HX12'WX20'L-NO INJURIES CONTINUOUS MINER WAS CAUGHT VENTILATION WAS NOT INTERRUPTED. AREA HAD BEEN SUPPORTED WITH 4' FULLY GROUTED RESIN BOLTSFALL WILL NOT BE CLEANED UP
Big Springs #17 Mine: 2 reportable incidents Coal
Big Springs #17 Mine has had no fatalities among 2 reportable incidents since 1998.
Watch this mine
Email me when a new MSHA incident is filed at Big Springs #17 Mine.
- Fatalities
- 0
- Total incidents
- 2
- Years on record
- 1998
- Latest incident
- Dec 1998
- Consol Of Kentucky Inc 1997 to present
ⓘ
Coal production is reported quarterly and lags the current period; the most recent quarters may be incomplete.| Year | Employees | Coal produced (tons) |
|---|---|---|
| 1999 | 29 | 50,785 |
| 1998 | 43 | 430,536 |
| 1997 | 0 |
Big Springs #17 Mine sits in Knott County, Kentucky, where the Census mining category is 2.8% of county employment.
ⓘ
County figures come from the US Census Bureau's American Community Survey, 5-year pooled estimates, so the 2023 vintage covers 2019 through 2023. The Census category is 'mining, quarrying, and oil and gas extraction', which is broader than MSHA jurisdiction and includes oil and gas workers no mine employs. These figures describe the surrounding county, not this mine, and are not a factor in any specific incident.Reportable incidents
2 on file1998 · 2 incidents
AN UNITENTIONAL ROOF FALL OCCURRED IN THE #2 ENTRY 2ND BREAK INBY PORTAL. SIZE OF THE FALL WAS APPROXIMATELY 4-6' HIGH, 20-30' LONG. NO INJURIES, NO EQUIPMENT CAUGHT , VENTILATION WAS NOT INTE RRUPTED. AREA HAD BEEN SUPPORTED WITH 4' FULLY GROUTED RESIN BOLTS WITH SUPPLEMENTAL SUPPORT CONSISTING OF 9' COMBINATION BOLTS. FALL WILL BE CLEANED UP.
US Mine Safety and Health Administration. Mine record, Mine ID 1517996: Big Springs #17 Mine. Mining Incidents, miningincidents.org. https://miningincidents.org/mine/big-springs-17-mine-1517996. Accessed November 25, 2026.