ROCKFALL ON UNIT HEADER & MAIN LINE TAILPIECE. AT 11+81 ON N. E. MAIN TAIL & UNIT HEADER. THE FALL IS ABOUT 8' H & 40' L.
Diamond Mine: 13 reportable incidents Coal
MSHA record for Diamond Mine (mine ID 1517444). Fatalities, non-fatal incidents grouped by year, current operator and controller, and mine context.
Watch this mine
Email me when a new MSHA incident is filed at Diamond Mine.
- Fatalities
- 0
- Total incidents
- 13
- Years on record
- 1993–1994
- Latest incident
- Dec 1994
- Diamond Mining Company 1993 to present
Diamond Mine sits in Webster County, Kentucky, where the Census mining category is 4.5% of county employment.
ⓘ
County figures come from the US Census Bureau's American Community Survey, 5-year pooled estimates, so the 2023 vintage covers 2019 through 2023. The Census category is 'mining, quarrying, and oil and gas extraction', which is broader than MSHA jurisdiction and includes oil and gas workers no mine employs. These figures describe the surrounding county, not this mine, and are not a factor in any specific incident.Reportable incidents
13 on file1994 · 9 incidents
ROCK FALL ACROSS #6 AND 7# ENTRIES AT 1+40 IN N.E.
ROCKFALL OLD NW HEADINGS 2ND XCUT OUTBY LAST OPERN BETWEEN #6 ENTRY 1/2WAY IN INTERSECTION 25FTX19FTX6FT THIS AREA WAS MINED IN JAN 94 & BOLTED WITH 5FT &6FT TENSION REBAR ROOF BOLTS & TIMB ERED THE FALL WAS CAUSED BY A HIDDEN SLIP
INSTALLING ROOF BOLT WITH AN EXTENSION WRENCH WHEN WRENCH CAME LOOSE STRIKING HIM ABOVE THE RIGHT EYE CAUSING A LACERATION REQUIRING 4 SUTURES.
PULLING ON MINER CABLE & FEET SLIPPED OUT FROM UNDER HIM CAUSING HIM TO STRAIN HIS LOWER BACK
LIFTING ROCK OUT OF UNIT BELT TAILPIECE AND STRAINED HIS BACK.
40' X 18' X 6'. NW ENTRIES--#6 ENTRY IN PILLAR LINE BETWEEN #18 & #19 X-CUT. THIS AREA WAS MINE IN JAN. 94 & BOLTED WITH 5' & 6' TENSION REBAR ROOF BOLTS. THE FALL WAS CAUSED BY A HIDDEN SLIP.
60X18X6 ORIGNIATED AT FACE IN AN UNBOLTED AREA AND FELL OUTBY 40 ADDITION FEET THERE WAS AN UNDETECTED MUD SLIP IN THE ROOF.
A ROOF FALL OCCURED AT 14 XCUT IN THE NORTH WEST ENTER IN THE PILLAR LINE BETWEEN 3 TO 4 X CUT 19X25X7 THE CAUSE OF THE ROOF FALL WAS UNDETECTED SLIP THE AREA HAD BEEN BOLTED WITH 5 TO 6 GLUE BOLTS ON 4X4 CENTERS.
1993 · 4 incidents
EE AND OTHER TOOK THE DOUBLE BOOM BOLTER INTO THE FACE OF 4 ENTRY INBY SPAD 6 & 20 TO BOLT A 20 FT CUT. THEY PUT UP THEIR 1 ST BOLT AND WERE IN THE PROCESS OF PUTTING UP THEIR 2ND BOLT WHEN A ROCK FELL AND HIT EE IN THE RIGHT SIDE CAUSING HIM TO FALL ON HIS RIGHT SHOULDER.
A FALL OF ROOF MEASURING 18X18X6 IN 4 ENTRY 5 X CUT INBY PORTAL AND 150 OUTBY THE FACE IT HAD BEEN BOLTED WITH 5 & 6 TENSION REBAR ROOF BOLTERS ON 4 FT CENTRESS WATER HAD BEEN DRIPPING OUT OF ROOF AND THEIR WAS AN UNDETECTED SLIP.
EMPLOYEE WAS CUTTING OPEN A CAN OF WELDING RODS WITH SIDE CUTTERS WHEN A PIECE OF THE CAN CAME LOOSE CUTTING HIM ON THE LEFT FOREARM. THE CUT REQUIRED 18 SUTURES.
EMPLOYEE WAS STEPPING DOWN OFF OF DOZER WHEN HE SLIPPED ON THE TRACK AND FELL APPROX. 4 1/2 FEET TO THE GROUND LANDING ON HIS RIGHT ARM HEAD.