THE EMPLOYEE SAID THAT HE WAS CUTTING AND LOADING COAL WITH THE CONTINUOUS MINER WHEN THE COAL RIB ROLLED AND STRUCK HIM IN THE UPPER BACK.
Mine No 3: 415 MSHA citations Coal
Mine No 3 has $65K in proposed MSHA penalties and $61K outstanding across 0 contested dockets, plus health sampling and the full incident record.
Watch this mine
Email me when a new MSHA incident is filed at Mine No 3.
- Fatalities
- 0
- Total incidents
- 21
- Years on record
- 2000–2004
- Latest incident
- Jul 2004
ⓘ
This rate is recorded citations divided by MSHA inspection hours, per 100 hours. It reflects inspection effort, not mine size or production.Mine No 3 has $65K in proposed MSHA penalties and $61K outstanding across 0 contested dockets.
ⓘ
Differences between proposed and paid penalties reflect both settlements and conference reductions and amounts still owed. Outstanding is the balance currently owed.ⓘ
Shares are computed over citations that carry the MSHA gravity and negligence coding; a small share of records are uncoded.MSHA sampling at Mine No 3 shows 95% of 507 respirable coal dust samples met the 1.5 mg/m3 standard.
ⓘ
A sample is a point in time compliance measurement, not an individual exposure history. These figures describe MSHA sampling records and do not establish causation or personal dose.Respirable coal dust
ⓘ
Respirable coal dust and silica figures cover coal facilities. Dust compliance is measured against the current 1.5 mg/m3 standard; samples predating the 2014 standard are included, so compliance rates are a coarse historical signal.
Last sampled: 2005-08-22, 21 years ago
ⓘ
Respirable coal dust and silica figures cover coal facilities. Dust compliance is measured against the current 1.5 mg/m3 standard; samples predating the 2014 standard are included, so compliance rates are a coarse historical signal.- CONTINUOUS MINER OPERATOR257
- SCOOP CAR OPERATOR41
- SHUTTLE CAR OPERATOR (STANDARD SIDE)29
Silica (quartz)
Last sampled: 2005-06-22, 21 years ago- CONTINUOUS MINER OPERATOR14
Noise
ⓘ
The share counts noise samples whose measured dose exceeded the 90 dBA permissible exposure limit. It describes the sampled workplace, not what reached the miner's ear: hearing conservation programs and the hearing protection worn during the shift are recorded separately and are not reflected here.
Last sampled: 2005-05-16, 21 years ago
ⓘ
The share counts noise samples whose measured dose exceeded the 90 dBA permissible exposure limit. It describes the sampled workplace, not what reached the miner's ear: hearing conservation programs and the hearing protection worn during the shift are recorded separately and are not reflected here.- SHUTTLE CAR OPERATOR (STANDARD SIDE)11
- CONTINUOUS MINER OPERATOR8
- UTILITY MAN6
ⓘ
A sample is a point in time compliance measurement, not an individual exposure history. These figures describe MSHA sampling records and do not establish causation or personal dose.ⓘ
Respirable coal dust and silica figures cover coal facilities. Dust compliance is measured against the current 1.5 mg/m3 standard; samples predating the 2014 standard are included, so compliance rates are a coarse historical signal.| Year | within 1.5 mg/m3 | samples |
|---|---|---|
| 2005 | 92% | 26 |
| 2004 | 97% | 72 |
| 2003 | 97% | 32 |
| 2002 | 98% | 124 |
| 2001 | 93% | 149 |
| 2000 | 95% | 104 |
| Year | silica avg (%) | samples |
|---|---|---|
| 2005 | 7.9 | 5 |
| 2004 | 8.4 | 8 |
| 2003 | 8.3 | 3 |
| 2002 | 10.6 | 10 |
| 2001 | 10.3 | 12 |
| 2000 | 8.9 | 12 |
| Year | over PEL | samples |
|---|---|---|
| 2005 | 0% | 6 |
| 2004 | 14% | 7 |
| 2003 | 0% | 4 |
| 2002 | 0% | 10 |
| 2001 | 10% | 10 |
Mine No 3 recorded 24.72 reportable injury cases per 100 full-time workers in 2004.
ⓘ
This rate is reportable injury cases per 100 full-time-equivalent workers per year, computed as 200,000 times cases divided by MSHA operator-reported employee-hours. Cases are injuries MSHA graded degree 01 through 07; accident-only events that hurt no one are excluded, and so are contractor injuries, whose hours do not attach to a single mine. Rates begin in 2000, when quarterly employment reporting starts, and are withheld below 20,000 hours in a year.| Year | total case rate | days-away | fatal |
|---|---|---|---|
| 2004 * | 24.72 | 24.72 | 0.000 |
| 2002 | 8.18 | 5.45 | 0.000 |
| 2001 | 2.28 | 0.00 | 0.000 |
| 2000 * | 10.89 | 8.71 | 0.000 |
- Paramont Coal Corporation 2000 to 2002
- Paramont Coal Company Virginia, LLC 2002 to 2003
- Kelly Branch Resources Incorporated 2003 to 2005
- Double A Mining Inc 2005 to present
ⓘ
Coal production is reported quarterly and lags the current period; the most recent quarters may be incomplete.| Year | Employees | Coal produced (tons) |
|---|---|---|
| 2006 | 0 | |
| 2005 | 4 | 4,502 |
| 2004 | 16 | 67,706 |
| 2003 | 10 | 37,988 |
| 2002 | 70 | 338,639 |
| 2001 | 74 | 372,752 |
| 2000 | 40 | 246,298 |
Mine No 3 sits in Dickenson County, Virginia, where the Census mining category is 9.8% of county employment.
ⓘ
County figures come from the US Census Bureau's American Community Survey, 5-year pooled estimates, so the 2023 vintage covers 2019 through 2023. The Census category is 'mining, quarrying, and oil and gas extraction', which is broader than MSHA jurisdiction and includes oil and gas workers no mine employs. These figures describe the surrounding county, not this mine, and are not a factor in any specific incident.ⓘ
Citations per million reported employee-hours. Rates begin in 2000, when MSHA's quarterly employment data starts; earlier incidents are counted but cannot be rate-adjusted. Quarters under 100,000 reported hours are greyed: too few hours for a stable rate.| Quarter | Hours worked | Citations | S&S | Per 1M hrs |
|---|---|---|---|---|
| 2006 Q1 | 0 | 0 | 0 | |
| 2005 Q4 | 0 | 11 | 0 | |
| 2005 Q2 | 2,460 | 89 | 31 | 36178.9 |
| 2005 Q1 | 800 | 4 | 0 | 5000.0 |
| 2004 Q4 | 4,294 | 71 | 22 | 16534.7 |
| 2004 Q3 | 6,874 | 38 | 10 | 5528.1 |
| 2004 Q2 | 6,904 | 42 | 20 | 6083.4 |
| 2004 Q1 | 6,202 | 22 | 10 | 3547.2 |
Show 16 earlier quarters Hide earlier quarters
| Quarter | Hours worked | Citations | S&S | Per 1M hrs |
|---|---|---|---|---|
| 2003 Q4 | 6,608 | 15 | 5 | 2270.0 |
| 2003 Q3 | 5,644 | 14 | 10 | 2480.5 |
| 2003 Q2 | 2,142 | 12 | 10 | 5602.2 |
| 2003 Q1 | 0 | 0 | 0 | |
| 2002 Q4 | 32,458 | 1 | 1 | 30.8 |
| 2002 Q3 | 36,877 | 2 | 1 | 54.2 |
| 2002 Q2 | 33,280 | 4 | 1 | 120.2 |
| 2002 Q1 | 44,086 | 6 | 2 | 136.1 |
| 2001 Q4 | 44,489 | 4 | 2 | 89.9 |
| 2001 Q3 | 45,964 | 5 | 3 | 108.8 |
| 2001 Q2 | 41,719 | 5 | 1 | 119.8 |
| 2001 Q1 | 43,410 | 3 | 0 | 69.1 |
| 2000 Q4 | 40,461 | 3 | 3 | 74.1 |
| 2000 Q3 | 30,921 | 2 | 0 | 64.7 |
| 2000 Q2 | 19,501 | 6 | 3 | 307.7 |
| 2000 Q1 | 972 | 1 | 1 | 1028.8 |
Reportable incidents
21 on file2004 · 3 incidents
Employee said he raised lid on battery to water the batteries on the 488 scoop and that the lid fell, striking him on the hand, left hand, hurting middle index finger.
Employee claims back injury while laying track.
2002 · 9 incidents
ROOF FALL WAS DISCOVERED BY THE SECTION FOREMAN. IT WAS APPROXIMATELY 7250' OUT OF THE FACE AREA AND WAS BY THE #7 ENTRY. THE AREA MEASURED 23' X 21' WIDE X 12' HIGH AND DOES NOT AFFECT VENTIL ATION AND NO EQUIPMENT OR PEOPLE WERE INVOLVED.
THIS FALL OF THE MINE ROOF WAS DISCOVERED BY FOREMAN WHILE TRAVELING THE INTAKE AIRWAY TO THE WORKING SECTION. FALL WILL NOT BE CLEANED UP, VENTILATION NOT AFFECTED NOR THE ESCAPEWAY AFFECTED. THE AREA WAS BOLTED WITH 6' TENSION POINT ANCHOR BOLTS. FALL WAS APPROXIMATELY 9100 FEET OUTBY THE WORKING SECTION #2 BELTLINE OF THE NORTHWEST MAINS.
THE FALL OCCURRED AS THE 001 CONTINUOUS MINER WAS CUTTING THE RIGHT PILLAR CUT OUT OF THE #4 BLOCK. THE MINER WAS CAUGHT FROM THE CUTTER DRUMS BACK TO THE CUTTER BOOM HINGE POINT. THIS MINE US ES THE MINERS TO PILLAR WITH UTILIZING THE 3-CUT PILLAR PLAN. THE INCIDENT OCCURRED APPROXIMATELY 70' INBY SURVEY STATION #3587.
EE WAS CLEANING BELT WHEN HE WAS EMPTYING HIS SHOVEL WHEN HIS SHOVEL CONTACTED A PIECE OF ROCK THAT WAS ON THE BELT CAUSING THE SHOVEL TO KICK BACK AND THE HANDLE STRUCK THE EE INT HE MOUTH CA USING 2 FRACTURE OF 2 TOOTH.
EE WAS KNEELING BESIDE ROOF BOLTER WHEN THE EE WAS BENDING ROOF BOLTS WHEN HE FELT PAIN IN HIS LEFT GROIN AREA.
EE KNEELD DOWN BESIDE CAR TO HOOK UP PULL ROPE TO PULL MINER CABLE AND STARTED TO GET UP TO GET BACK ON CAR WHEN HE TWISTED HIS LEFT KNEE.
EMPLOYEE WAS IN THE PROCESS OF CHANGING A TIRE ON THE S&S 488 SCOOP. AS HE REMOVED THE TIRE FROM THE SCOOP HE FELT A PAIN IN HIS LOWER BACK.
THIS EE HAS BEEN DIAGNOSED AS HAVING CARPAL TUNNEL SYNDROME IN BOTH HANDS DUE TO REPETITIVE TRAUMA AND CORRECTIVE SURGERY HAS BEEN DONE ON THE RIGHT HAND AND SURGERY FOR THE LEFT HAND HAS BEEN SCHEDULED FOR 4-26-02.
EE HAD INSTALLED A ROOF BOLT & WAS STARTING TO GET OUT FROM UNDER THE CANOPY. HE WAS ON HIS TOES & AS HE WAS TURNING AROUND HE FELT A POP IN HIS RIGHT KNEE & FELT PAIN. ON 4/17/02 THE EE HAD S URGERY TO CORRECT THE PROBLEM.
2001 · 4 incidents
ROOF FALL WAS DISCOVERED BY FIRE BOSS IN THE #2 ENTRY 90'INBY SS#479. FALL IS 20'LONG X 18'WIDE X 9'THICK IN THE INTERSECTION. FALL WILL NOT BE CLEANED UP AND DOES NOT EFFECT VENTILATION OR ES CAPEWAYS.
ROOF FALL WAS DISCOVERED IN THE #8 ENTRY IN RIGHT RETURN. SIZE OF FALL 30'LONG X 17'WIDE X 9'THICK. SUPPLEMENTAL SUPPORT WAS INSTALLED IN AREA. HAS BEEN DANGERED OFF, FALL WILL NOT BE CLEANED UP.
EE STATED WHILE WALKING TOWARD HIS VECHILE IN PARKING LOT HE STRUCK HIS RIGHT KNEE AGAINST A EXHAUST PIPE OF VEHCILE PANTKER BESIDE HIS CAUSING A LACERATION.
EE STATES HE WAS BEHIND MINER REMOVING CONVEYOR BOOM JACK FROM MINER. EE WAS SHAKING JACK IN AN ATTEMPT TO FREE IT FROM GOB. JACK BECAME LOOSE AND CAUGHT MIDDLE FINGER LEFT HAND AGAINST FRAME OF MINER, RESULTING IN LACERATION.
2000 · 5 incidents
ON 2/1/01 EE REPORTED AN ALLEGED INJURY BY PHONETO A MINE SUPERVISOR AT HIS HOME. THE ALLEGED INJURY WAS TO HAVE OCCURED WHILE THROWING ROOF BOLT PLATES ACROSS THE ROOF DRILL TO HIS COWORKER AND STRUCK HIS HEAD AGAINST THE DRILL WC HAS RULED COMPENSIBLE. INTERVER INVESTIGATION EVALUATEDTHE COWORKER REMEMERED EE HURTING HAND SOMETIME IN 2000. NO MANAGEMENT EE WAS AWARE OF ISSUE PRI
EE STATES HE WAS RIDING W MANTRIP TO SECTION WHEN MANTRIP WENT THRU DEEP AND BETWEEN OUT CAUSING PAIN IN LOWER BACK ALLEGED ACCIDENT ON 10-10-00 WAS TREATED AS FIRST AID. EE HAS HAD BACK SURGR Y FOR PREVIOUS ACCIDENT ON JAN 1995. INCIDENT WAS TREATED AS RECORRAUCNE BY MEDICAL PERSONAL OF OLD INJURY ON 11-14-00. MEDICAL SPECIALIST MADE ASSEMBENT THAT THERE WAS A NEW INJURY AT WHICH
EMPLOYEE STATED HE WAS HELPING MINER CABLE ALONG WITH 2 OTHER EMPLOYEES WHEN HE EXPERIENCED PAININ HIS LEFT SHOULDER. EMPLOYEE WORKED UNTIL 10-17-00 WHEN DOCTOR PLACED HIM ON NON-WORKING STATU S PENDING MEDICAL EXAM RESULTS.
EMPLOYEE WALKED BESIDE ROOF DRILL; A PIECE OF ROCK SUDDENLY BROKE FROM THE TOP, STRIKING HIM. INITIAL VISIT TO EMERGENCY ROOM REVEALED NO FRACTURE, BUT REVISIT TO SPECIALIST ON 8/16/00 REVEAL ED A NON-DISPLACED FRACTURE OF 9TH RIB ON LOWER RIGHT SIDE.
EMPLOYEE STATES HE WAS OPERATING A CINTINUOUS MINER WHEN A PIECE OF DRAW DISLODGED FROM BEHIND BOLTS AND RIBS STRIKING HIM ON THE HEAD, LEFT ARM, WRIST. REFERRED TO SPECIALIST ON 7-25-00 WHEN HE WAS PLACED ON RESTRICTED DUTY.