The inspection cover on the VSI was open, the employee bumped the plate causing the cover to shut. The plate struck the employee, resulting in a broken arm. Two conditions contributed to the accident (1) the inspection cover lacked an OEM locking mechanism to hold it safely open (2) the employee was new to the position and had not developed adequate safety awareness.
PCR-1Metal/Nonmetal
Tidewater Contractors, Inc. · Surface
Controlled by George Harold Fitzhugh; John David Baldwin
John Day, Grant County, OR · Intermittent
MSHA Mine ID: 0405838
- Fatalities
- 0
- Total incidents
- 2
- Years on record
- 2020–2025
- Latest incident
- Jul 2025
No fatalities recorded at this mine.
Reportable incidents
2 on file2025 · 1 incident
Struck by falling object
2020 · 1 incident
Fall to the walkway or working surface
Miner turned switch for batteries on Horizontal, sitting on 4ft elevated surface. Bank of surface sloped 1:1. Miner stepped back and lost footing. Miner slipped down bank, put left arm out to brace. Miner heard pop, experienced shoulder pain. Initial injury occurred on 12/14/20. Simple strain diagnosis and no time loss. On 5/27/21 Miner approved for surgery, therefore reportable.