EE WAS BURNING BOLTS OFF OF BELT TAIL WHEN HE STEPPED BACK AND FELL OFF OF TAIL STRIKING HIS RIGHT SIDE ON SUPPLY CAR.
Florence Mine No 2 Coal
Watch this mine
Email me when a new MSHA incident is filed at Florence Mine No 2.
- Fatalities
- 0
- Total incidents
- 200
- Years on record
- 1988–1992
- Latest incident
- Sep 1992
Reportable incidents
200 on file1992 · 3 incidents
55061S GREASING BELT TAKE UP FOR OVERLAND BELT HE PUSHED IN ON GUARD TO REACH GREASE FITTING THE GUARD CONTACTED THE BELT CAUSING IT TO KICK BACK STRIKING HIS NOSE.
ROOF FALL ABOVE ROOF BOLT ANCHORAGE STATION 8047 #5 ENTRY OF PARALLELS. FALL WAS APPROX. 30' X 20' X 6'-10' HIGH. THE ROOF HAD BEEN SUPPORTED WITH 6' AND 9' COMBINATION BOLTS.
1991 · 58 incidents
ROOF FALL ABOVE ROOF BOLT ANCHORAGE LOCAT ED IN D MAINS #1 ENTRY 50FT INBY STATION 5 199 FALL IS APPROX 60FT LONGX5FT HIGH X18FT WIDE ROOF HAD BEEN SUPPORTED BY 4FT RESIN BOLTS & MATS
ROOF FALL ABOVE BOLT ANCHORAGE #5 ENTRY OF PARELLES 70' INBY STATION 7655 5'X20'X20'. ROOF HAD BEEN SUPPORTED WITH 4' RESIN BOLTS.
EMPLOYEE WAS WALKING WHEN THE TRIPPED OVER A BAG OF ROCK DUST CAUSING PAIN IN RIGHT KNEE.
EMPLOYEE WAS MOVING OXYGEN TANK WHEN HE FELT PAIN IN BACK.
EMPLOYEE WAS SHOVELING AS HE WAS LIFTING SHOVEL IT GOT CAUGHT BY BOTTOM ROLLER CAUSING PAIN IN BACK & GROIN
EMPLOYEE WAS STEPPING OFF DEISEL MOTOR WHEN HE SLIPPED & FELL INJURING HIS LEFT KNEE
ELECTRICAL TROUBLE ON ELEVATOR FROM 11 AM TO 3:30 PM. BAD SWITCH ON TOP OF CAR.
EMPLOYEE WAS REACHING FOR DRILL STEELS IN TRAY ON BOLTER WHEN HE FELT PAIN IN HIS BACK.
EMPLOYEE WAS USING A 6' BAR TO MOVE TOOL BOX CLOSER TO RIB WHEN HE FELT PAIN IN GROIN.
EMPLOYEE WAS PULLING MINER CABLE WHEN HE FELT PAIN IN UPPER BACK.
EMPLOYEE WAS GOING THRU A MANDOOR WHEN HE HIT HIS HEAD ON THE ROOF.
ROOF FALL ABOVE BOLT ANCHORAGE B-1 #3 ENTRY STATION 7206. ROOF HAD BEEN SUPPORTED WITH INSTALL 1A BOLTS. THE SIZE OF THE FALL IS 20' X 120' X 6'-8'.
EMPLOYEE WAS CARRYING ROCKDUST WHEN HE HIT HIS HEAD ON WATER FOR BELT FIRE SUPPRESSION.
ROOF FALL ABOVE BOLT ANCHORAGE D MAINS #2 ENTRY.40'INBY STATION 5583. 100'LONG X 20'WIDE X 6-8'HIGH.ROOF HAD BEEN SUPPORTED BY 6'COMBINATION BOLTS.
EMPLOYEE WAS GRINDING WELD OFF OF CAT FRAMES WHEN HE GOT METAL & RUST IN HIS EYES HE WAS LAYING ON HIS BACK & WESARING EYE PROTECTION
EMPLOYEE WAS OPERATING A SHUTTLE CAR WHEN HE HIT A BUMP AND STRUCK HIS HEAD AGAINS THE CANOPY.
ROOF FALL ABOVE ROOF BOLT ANCHORAGE IN 4 LEFT NO. 2 ENTRY AT 9+40. FALL IS 40' X 20' X 6'. ROOF HAD BEEN SUPPORTED WITH 4' RESIN BOLTS AND MATS.
EMPLOYEE PICKED UP A BAG OF ROCK DUST AND TURNED TO SET IT DOWN WHEN HE FELT PAIN IN HIS BACK. HE WAS ON HIS KNEES AT THE TIME.
EMPLOYEE WAS GETTING OUT OF SHUTTLE CAR TO MOVE A CABLE WHEN HE SLIPPED AND FELL CAUSING INJURY TO RIGHT WRIST.
EMPLOYEE WAS PULLING MINER CABLE WHEN HE FELT PAIN IN RIGHT ARM AND SHOULDER.CASE NOT DECIDED UNTIL 07-23-91.
EMPLOYEE STATES HE WAS STANDING ON TOP OF 6 PALLETS LOOKING INTO DUMPSTER.PALLETS MOVED CAUSING LEFT FOOT TO FALL BETWEEN BOARDS,CAUSING HIM TO FALL INJURING LEFT KNEE.CASE NOT DECIDED UNTIL 0 7-08-91.
EMPL WALKING,HIT HEAD ON MINE ROOF.CASE NOT DECIDED UNTIL 6-28-91.
EMPLOYEE WAS WALKING WHEN HE TRIPPED & FELL DOWN 3 STEPS 30IN TO GROUND
CLEANING ROCK OFF MINER ROCK SLID AND STRUCK L RING FINGER
ROOF FALL ABOVE BOLT ANCHORAGE #4 AND X-CUT 4-5 AT 6/00 IN PARALLELS.FALL WAS 30' X 20' X 6-10'HIGH.THE ROOF HAD BEEN SUPPORTED WITH 9'KEYSTONE COMBINATION BOLTS.
OPER SHUTTLE CAR, ROCK EJECTED FROM MINER TAIL,BOUNCED STRUCK HIM ON L EAR
EXTENSION OF PILLAR FALL ONTO CONTINUOUS MINER AT 27 STUMP IN A BUTT THE FALL COVERED APPROX. 23 FT OF THE MINER.
ULOADING CRIB FROM CAR END OF CRIB SLIPPED FELL STRUCK L FOOT
EMPLOYEE WAS TIGHTENING WHEEL LUGS ON SHUTTLE CAR WHEN HE FELT PAIN IN RT. SHOULDER.
ROOF FALL ABOVE ROOF BOLT ANCHORAGE 50' X 20' X 6'-7' IN #4 ENTRY AND S-CUT 4-5 AT 4+50 IN PARALLELS SECTION. ROOF HAD BEEN SUPPORTED WITH 6' COMINATION BOLTS AND MATS AND SOME ROOF RAILS.
SHOVELING PC OF RIB FELL KNOCKING AGAINST BELT RAIL FOUND UNCONSCIOUS WITH PC OF RIB ON FOOT
EE WAS GETTING INTO SCOOP OPERATOR SEAT WHEN FELT PAIN IN HIS RIGHT LEG AND HIP.
HOIST DOWN FROM 920 AM TO 1020 AM A CONTACTOR TIP ON HOIST BRAKE BURNED OFF REPAIRED.
ROOF FALL ABOVE ROOF BOLT ANCHORAGE DMAINS 6&7 ENTRIES 75FTX20FTX6FT-8FT HIGH ROOF HAD BEEN SUPPORTED WITH 6FT INSTALL 1A BOLTS
WALKING A LONG BELT WHEN EE SLIPPED ON WET BOTTOM AND FELL CATCHING HIMSELF WITH RIGHT ARM.
ROOF FALL ABOVE BOLT ANCHORAGE 0-1 ENTRIES OF PAR MAINS AT STATION 7442B. ROOF HAS BEEN SUPPORTED WITH 4' & 6' RESIN BOLTS. 70' LONG X 20' WIDE X 6' HIGH.
EMPLOYEE WAS PULLING A PIECE OF ROOF DOWN BETWEEN ATRS AND LAST ROW OF BOLTS. THE ROCK FELL STRIKING A DRILL STEEL LAYING IN BOLTER TRAY. THE STEEL FLEW UP STRIKING HIS LEFT HAND.
EMPLOYEE WAS GETTING INTO SCOOP OPERATOR SEAT PULLING HIMSELF UP BY HAND HOLES ON CANOPY WHEN HE FELT PAIN IN LEFT SHOULDER
ROOF FALL ABOVE ROOF BOLT ANCHORAGE LOCATED IN #3 ENTRY OF PAR SUMP TR. 50' INBY STATION 7116. ROOF HAD BEEN SUPPORTED WITH 6' INSTALL 1A BOLTS ANDF MATS. THE FALL IS 150' LONG X 22' WIDE X 8' -10' HIGH.
EMPLOYEE WAS UNLOADING SUPPLIES FROM TRANSPORT WHEN HE HIT HIS HEAD ON THE ROOF.
EMPLOYEE WAS OPERATING A SHUTTLE CAR WHEN HE EXPEREINCED BACK PAIN. NO SPECTIFIC INCIDENT. INDUSTRIAL ILLNESS CASE NOT DECIDED UNTIL 4-30-90.
EE WAS HANGING MINER CABLE WHEN THE WIRE BEING USED TO HANG THE CABLE BROKE, CAUSING THE CABLE TO FALL AND BENDING HIS WRIST BACKWARDS.
EMPLOYEE WAS SETTING RAILS USING A MASON HAMMER TO TIGHTEN WEDGES. WHEN HAMMER APPARENTLY STRUCK RAIL CAUSING HAMMER TO BOUNCE BACK STRIKING HIM IN MOUTH CRACKING AND CHIPPING FRON TEETH.
WAS HELPING 4 OTHER MEN INSTAL AIR LOCK FELT PAIN IN BACK LATER IN SHIFT.
EMPLOYEE WAS TRAMMING A SHUTTLE CAR WHEN THE CAR STRUCK A POST LAYING ALONG THE RIG,CAUSING THE POST TO COME INTO THE OPERATORS COMPARTMENT STRIKING HIM ON HIS RIGHT SIDE.
EMPLOYEES HANDS SWELLED UP AFTER 2 DAYS OF USING JACK HAMMER DOCTORS SLIPPED SAYS REPEATED TRAUMA
EMPLOYEE WAS SHOVLEING ALONG BELT WHEN SHOVEL CONTACTED ROLLER CAUSING SHOVEL TO KICK BACK STRIKING HIS LEFT ARM.
EMPLOYEE WAS OPERA TING MINER CUTTING ROCK WHEN MINER BROUNCED CAUSING HIM TO JAR HIS BACK
INJ SCALING ROOF PRIOR TO DRILLING ROOF BOLT HOLE.STANDING UNDER CANOPY.ROOF WAS 10'HIGH.ROCK FELL STRIKING CANOPY THEN STRIKING INJ ON BACK FORCING HIM TO BOTTOM STRIKING RIGHT KNEE ON BOTTOM
EMPLOYEES WAS WALKING ON HIS KNEES CARRYING A BOX OF RESIN WHEN HE TWISTED HIS KNEE
EE WAS WALKING WHEN HE STRUCK HIS HEAD ON THE ROOF.
ROOFFALL ABOVE ROOF BOLT ANCHORAGE PARALLEL MAIN 0-6 ENTRIES AT 43+90. FALL ISAPPROX500' LONGX10' HIGH ROOF HAD BEEN SUPPORTED WITH 4' & 6' RESIN BOLTS. STARTED TO REBOLT AREA WITH 6' COMBINAT ION BOLTS.
EMPLOYEE WAS INSTALLING A 4 RESIN BOLT WHEN A PIECE OF ROCK FELL STRIKING HIS LEFT INDEX FINGER.
EMPLOYEE WAS PERFORMING REGULAR JOB AS MINER HELPER WHEN HE EXPERIENCED BACK PAIN AT END OF SHAFT. EMPLOYEE HAS BEEN EXPERIENCING BACK PAIN FOR PAST YEAR. NO SPECIFIC INCIDENT.
EE WAS SETTING A POST ALONG BELT WHEN HE PINCED HIS RIGHT INDEX FINGER BETWEEN TWO POSTS.
EMPLOYEE WAS LIFTING AND PULLING RAILS OFF TRANSPORT AND EXPERIENCED NECK AND SHOULDER PAIN.
EMPLOYEE WAS WALKING WHEN HE STRUCK HIS HEAD ON THE ROOF INJURING HIS NECK.
ROOF FALL ABOVE BOLT ANCHORAGE 5 RIGHT #2 ENTRY 7+50. THE FALL IS 21'X43'X6'-8' HIGH. THE ROOF HAS BEEN SUPPORTED WITH 6' COMBINATION BOLTS AND T.5 MATS.
1990 · 53 incidents
STEPPED OFF JEEP, TWISTED R ANKLE
ROOF FALL ABOVE ROOF BOLT ANCHORAGE 5 RIGHT #4 WENTRY AT 3/85. ROOF FALL IS 20' X 20'X 6-8'HIGH.ROOF HAD BEEN SUPPORTED WITH 4'INSTALL 1A BOLTS.
EMPLOYEE WAS ON SURFACE TRYING TO UNCOUPLE SUPPLY CARS WHEN HIS HAND SLIPPED AND HE STRUCK LEFT MIDDLE FINGER ON SUPPLY CAR.
CHECKING ROOF, ROCK FELL HE JUMPED BACK FELL ON R SIDE INJ RT SHOULDER ; Y
EMPLOYEE WAS WALKING FROM SHUTTLE CAR TO MINER WHEN HE HIT HIS HEAD ON THE ROOF.
INJURED WAS WORKING ON ROOF BOLTER CABLE REEL.AFTER WORKING ON REEL HE EXPERIENCED BACKPAIN. CASE NOT DECIDED UNTIL 11-08-90.
EMPLOYEE WAS PUTTING SIDE RAIL ON MINER BACK INTO PLACE. HE HIT SIDE RAIL WITH HAMMER. RAIL BOUNCED OUT AND FELL ON LEFT FOOT.
ROOF FALL ABOVE ROOF BOLT ANCHORAGE, 5 RIGHT #2 ENTRY. THE WAS APPROX. 20' X 20' X UNKNOWN HEIGHT. ROOF HAD BEEN SUPPORTED WITH COMBINATION BOLTS (6') AND ROOF MATS.
EMPLOYEE WAS WALKING WHEN HE STRUCK HIS HEAD ON A ROOF MAT. LACERATION RIGHT SIDE OF TEMPLE.
ROOF FALL ABOVE BOLT ANCHORAGE #4 ENTRY 5 RIGHT 5+20. 30' LONG X 20' WIDE X 6-8' HIGH. ROOF FALL STARTED IN UNBOLTED FACE.
ROOF FALL ABOVE BOLT ANCHORAGE DMAINS 7TRACK#5 ENTRY 1XCUT INBY STAT7395 FALL WAS 60FT LONG X20FT WIDE X6FT-8FT HIGH THE ROOF HAD BEEN SUPPORTED WITH 6FT INSTALL 1A BOLTS
EMERGENCY STOP ACCIDENTALLY PUSHED ON ELEVATOR-MTION SWITCH KICKED ON TOP OF ELEVATOR.15 MEN ON ELEVATOR UNTIL 5:15 WHEN SWITCH WAS RESET.
ROOF FALL D AINS #2 ENTRY ACROSS FROM STATION 7384 #3 ENTRY. FALL WAS 40' LONG X 20' WIDE X 6 -8' HIGH. ROOF HAD BEEN SUPPORTED BY 6' INSTALL 1A BOLTS & MATS.
WALKING STRUCK HEAD ON OVERCAST
ROOF FALL ABOVE BOLT ANCHORAGE #7 ENTRY NEMAINS 50' INBY STATION 2262. FALL IS 15' LONG X 20' WIDE X 8' HIGH. ROOF HAD BEEN SUPPORTED WITH 6' CONVENTIONAL BOLTS AND MATS.
ROOF FALL ABOVE BOLT ANCHORAGE DMAINS#1 ENTRY 30FT LONGX20FTWIDE XABOVE 4IN INSTALL #1ABOLTS
ROOF FALL ABOVE ROOFBOLT ANCHORAGE D MAINS #3 ENTRY 30FT LONGX20FT WIDE X61/2FT HIGH ROOF HAD BEEN SUPPORTED WITH 4FT INSTALL 1@A BOLTS
ROOF FALL ABOVE ROOF BOLT ANCHORAGE #2 ENTRY 3 LEFT 2+45.ROOF FALL IS 30' LONG X 20' WIDE X 6'-8'' HIGH. ROOF HAD BEEN SUPPORTED WITH 6' 1A BOLTS & MATS.
ROOF FALL ABOVE ROOF BOLT ANCHORAGE D MAINS S CUT 4-S. FALL WAS 70' LONG X 20' WIDE X 6' HIGH. ROOF HAD BEEN SUPPORTED WITH INSTALL 1A BOLTS.
EMPLOYEE WAS GETTING OFF BUS WHEN HE ST RUCK HIS RT LEG ON STEEL ABOX FOR
ROOF FALL ABOVE ROOF BOLT ANCHORAGE #3 ENTRY OF B1 OFF 1 LEFT THE FALL STARTED 100' INBY STATION 7119.THE FALL IS 8' HIGH X20' WIDE X60' LONG.ROOF HAD BEEN SUPPORTED WITH 4'RESIN BOLTS.
EMPL WAS TIGHTNING BIT BLOCKS ON 14 CM MINER WHEN FELT PAIN IN GROIN AREA.
EMPLOYEE WAS MOVING BOLTER BOOM FROM RIB BOLT TO CENTER BOLT WHEN HE PINCHED HIS RIGHT INDEX FINGER BETWEEN BOOM FRAME AND BOLT HEAD AND SAFETY POST.
ROOF FALL ABOVE ROOF BOLT ANCHORAGE IN D MAINS #2 ENTRY STARTING AT 24 + 65 AND EXTENDING INBY 180' X 20' X 6'-8' HIGH. THE ROOF HAD BEEN SUPPORTED WITH 4' INSTAL 1A BOLTS.
EMPLOYEE WAS OPERATING SHUTTLE CAR AND STRUCK HEAD ON CANOPY DURING SHIFT.INVESTIGATION NOT COMPLETED UNTIL 09-28-90.
EMPL BLOCKING DISCHARGE ROLLER.STANDING IN FRONT OF FORKS ON HYSTER IT DRIFTED FORWARD AND THE R TIRE STRUCK LEFT FOOT.
ROOF FALL ABOVE BOLT ANCHORAGE D MAINS #1 ENTRY 100' INBY STATION #5183. THE FALL IS 30' LONG X 20' WIDE X 5' HIGH. THE ROOF HAD BEEN SUPPORTED WITH 4' RESIN BOLTS AND STRAPS.
INJURED WAS OPERATING MINER WHEN THE 10SC SHUTTLE CAR HIT THE BACK OF THE MINER CAUSING INJURED TO STRIKE HIS BACK AGAINST MINER FRAME.
CONTINUATION OF ROOF FALL ON 7-2-90 IN DMAINS #7 ENTRY. ORIGINAL FALL STARTED AT 16+60 AND FELL FOR 200'. THIS EXTENDED THE FALL TO 350' OR AN ADDITIONAL 150'. THE AREA HAD BEEN SUPPORTED WITH 6' INSTALL BOLTS AND SOME CRIBBS.
EMPLOYEE WAS PLUGGING IN PRESSURE PUMP AT POWER CENTER. THE PLUG SLIPPED OUT AND PINCHED HIS FINGER AGAINST FRAME OF POWER CENTER.
ROOF FALL ABOVE ROOF BOLT ANCHORAGE J#6 ENTRY D MAINS STATION 6620.FALL CONTINUES THRU X-CUT INTO #5 ENTRY.FALL WAS 130'LONG X 70'WIDE X 6-8'HIGH.ROOF HAD BEEN SUPPORTED BY 4'RESIN BOLTS.
ROOF FALL ABOVE ROOF BOLT ANCHORAGE AT INTERSECTION OF #3 ENTRY AND #1 ROOM OF 3 LEFT. THE FALL WAS 20' WIDE X 8' HIGH X 30' LONG. THE ROOF HAD BEEN SUPPORTED WITH 6' INSTAL BOLTS AND STRAPS .
THE DOORS ON THE ELEVATOR WERE NOT WORKING. THE ELEVATOR WAS REPAIRED AND PUT BACK IN SERVICE.
ROOF FALL ABOVE BOLT ANCHORAGE 7 ENTRY D MAINS STARTING 10 FT INBY 16 &60. THE FALL IS 200 FT LONG X 20 FT WIDE X 5-6'LONG THE ROOF HAD BEEN SUPPORTED WITH 6 FT INSTAL 1A BOLTS.
ROOF FALL ABOVE ROOFBOLT ANCHORAGE #3 ENTRY SUMP RT PARALLELS FALL STARTED 40'INBY STA 7203.FALL IS 8'HIGH X 20'WIDE X 80'LONG.ROOF HAD BEEN SUPPORTED WITH 6' INSTAL 1A BOLTS AND MATS.
ROOF FALL ABOVE ROOF BOLT ANCHORAGE #5 ENTRY NE MAIN 60' INBY STATION 4441. THE FALL WAS 5' HIGH X 20' LONG X 20' WIDE. THE ROOF WAS SUPPORTED WITH 4' RESIN BOLTS.
EMPL TRAMMING BOLTER,BOLTER STRUCK POST SUPPORTING RIB,PART OF RIB FELL INTO OPER DECK INJURING LEFT ANKLE.
STOPPED ABOVE TOP LANDING. ELEVATOR REPAIRED AT 7 AM.
ELEVATOR STOPPED 5' FROM TOP LANDING WITH ONE MAN ON ELEVATOR. THE COUNTER WEIGHT CHAIN WRAPPED AROUND THE BEAM AT THE BOTTOM OF THE SHAFT. ELEVATOR READY FOR USE AT 6:20 PM.
ROOF FALL ABOVE BOLT ANCHORAGE 100' LONG #4 ROOM OF 7 PANEL AND 250' LONG ACROSS 8 PANEL- 6'-8' HIGH IN 1 LEFT RIGHT SIDE. THE ROOF HAD BEEN SUPPORTED WITH RESIN BOLTS (4').
EMPLOYEE WAS LIFTING AND CARRYING A BUCKET OF B BOND IN LOW AREA WHEN HE DEVELOPED PAIN IN LOWER BACK.
EMPLOYEE WAS THROWING A ROCK INTO X-CUT WHEN HE CAUGHT HIS FINGER BETWEEN THE ROCK AND THE RIB.
ELECTRICAL FIRE IN HIGH VOLTAGE ENO OF 750 KVA BOX AT E BUTT 1 BELT DRIVE. SMOKE 1 ST OBSERVED AT APPROX. 11 15 AM FLAMES ERUPTED SHORTLY AFTER FLAMES OUT AT 1135 AM THIS REPORT IS BEING FILED UNDER PROTEST IN THAT WE BELIEVE FIRE DULATION WAS ONLY 25 MIN.
ROOF FALL ABOVE BOLT ANCHORAGE #4 ENTRY OF NE MAINS AT STA 4447.FALL WAS 5'HIGH X 20'WIDE X 40'LONG.ROOF HAD BEEN SUPPORTED BY 4'RESIN BOLTS AND STRAPS.
EMPLOYEE WAS OPERATING MINER, CUTTING ROCK, WHICH WAS HARD CUTTING AND CAUSED MACHINE TO BOUNCE. INJURED STRUCK HIS HEAD ON MINER CANOPY.
ROOF FALL ABOVE ROOF BOLT ANCHORAGE DMAINS #6 ENTRY 8+30. THE FALL WAS APPROX. 30'X40' LONG X 20' WIDE AND OVER 6' HIGH. THE ROOF HAD BEEN SUPPORTED WITH INSTALL 1A BOLTS 6' LONG.
EMPL SCALING ROOF WHEN ROCK FELL.INJ FELL BACK AND TWISTED RIGHT KNEE.
EMPLOYEE WAS WALKING DRAGGING CANVAS WHEN HE HIT HIS HEAD ON THE ROOF-REPEATED TRAUMA-THIS IS AN INOUSTRIAL ILLNESS-DOCTOR'S REPORT ATTACHED.
EMPLOYEE WAS LIFTING A 3INX8INX16FT PLANT WITH 3 OTHER MEN WHEN HE EXPERIENCED BACK PAIN CASE NOT DECIDED UNTIL 03-15 -90
EXPER BACK PERFORMING REG DUTIES OF RF BOLTER NOT SURE HOW IT OCC
EMPLOYEE WAS SETTING UP TO DRILL A HOLE IN ROOF. HE HAD HAND ON END OF STEEL WHEN HE RAISED BOLTER HEAD HE PINCHED LEFT HAND BETWEEN STEEL AND ROOF.
ELEV. DOORS WOULD NOT OPEN AT BOTTOM LANDING ON EMP WAS STUCK IN ELE FOR 40 MIN. ELEV BACK IN SERVICE AT 2:00 AM
EMPLOYEE WAS OPERATING A SHUTTLE CAR WHEN HE HIT A HOILE IN THE ROADWAY, JARRING HIS NECK AND LEFT SHOULDER.
1989 · 50 incidents
ROOF FALL ABOVE BOLT ANCHORAGE #6 ENTRY OF 02 MAINS 1 X-CUT OUTBY STATION 4481. THE FALL IS 6' HIGH X 15' WIDE X 15' LONG. THE ROOF HAD BEEN SUPPORTED WITH 4' RESINS BOLTS AND STRAD.
ROOF FALL ABOVE BOLT ANOCHORAGE #6 ENTRY 02 MAINS 1 X-CUT OUTBY 6 RIGHT SWITCH. THE FALL IS 5' HIGH X 15' WIDE X 20' LONG THE AREA HAD BEEN SUPPORTED BY 4' RESIN BOLTS AND STRAPS.
EMPL WAS IN ELEVATOR AT BOTTOM OF SHAFT.ELEVATOR WOULDNT MOVE AND DOORS WOULDNT OPEN.EMPL WAS REMOVED FROM ELEVAYOR 5:20 PM AND ELEVATOR WAS BACK IN SERVICE AT 6:55 PM. THERE WAS A LOOSE WIRE ON OVERLOAD.
CONTIOUS MINER WAS BACKING UP AND INJURED WAS MOVING CABLE OUT OF WAY WHEN HE FINGER WAS CAUGHT BETWEEN CABLE ARM AND COAL RIB.
ROOF FALL ABOVE ROOF BOLT ANCHORAGE 5 LEFT RIGHT SIDE RM #6 2ND INTERSECTION.FALL 5'HIGH X 20' X LENGTH UNK.AREA HAD BEEN SUPPORTED BY 4' RESIN BOLTS AND STRAPS.
EMPLOYEE PULLED LINE CANVAS DOWN & A ROCK FELL STRIKING HIM & CAUSING HIM TO FALL STRIKING HIS LEFT KNEE ON BOTTOM
ROOF FALL 1 ENTRY OF 5 LEFT AT 1 70 THE FALL WAS 5 FT HIGH X 20 FT WIDE X 20 FT LONG. THE AREA HAD BEEN SUPPORTED BY 4 FT RESIN BOLTS.
EMPL WAS REMOVING BATTERY LID FROM SCOOP WHEN HE TWISTED HIS BACK
ROOF FALL ABOVE ROOF BOLT ANCHORAGE 1 ENTRY OF D MAINS STATION 5457 THE FALL IS APPROX. 100 FT LONG X 20 FT WIDE X 6-8 FT HIGH. THE AREA HAD BEEN SUPPORTED BY 4 AND 6 FT INSTALL BOLTS AND MATS .
INJURED WAS MING A FINAL PUSHOUT STUMP IN STUMP OF BUTT BETWEEN ROOMS. AFTER LOADING THE LAST SHUTTLE CAR THE ROOF FELL WITHOUT WARNING COVERING THE MINER AND TRAPPING THE OPERATOR FOR 20 MIN UTES. THE ROOF FALL WAS APPROX 20 FEET WIDE, 10FEET HIGH, 30 FEET LONG.
ROOF FALL IN AREA OF STUMP. THE SIZE OF THE FALL WAS 70 FEET LONG,20 FEET WIDE, 6 FEET HIGH. THE AREA WAS SUPPORTED WITH RESIN BOLTS. THIS WAS AN EXTESION OF A PILLAR FALL. THE SECTION IS RETREAT MINING. THE FALL COVERED PART OF ROOF BOLTER.
EMPLOYEE WAS RIDING IN BUS WHEN ANOTHER BUS THAT PARKED DRIFTED OFF AND RAN INTO THE BUS HE WAS RIDING IN. INJURED SUFFERED A NECK SPRAIN.
EE BENT OVER TO PICK UP BOLTER CABLE WHEN THE BOLTER MOVED AROUND THE CORNER CAUSING THE CABLE OTO SWING ACROSS THE ENTRY. THE CABLE STRUCK HIS LEFT ANKLE CAUSING HIM TO FALL.
ROOF FALL ABOVE ROOF BOG ANCHORAGE #5 ENTRY 1 LEFT 1 X-OUT INBY STATION 5160. THE FALL WAS 20' WIDE X 5' HIGH X 30' LONG. THE AREA HAD BEEN SUPPORTED BY RESIN BOLTS 4' LONG.
EMPLOYEE GOT OFF 3 WHEELER & RAISED STRIKING HIS BACK ON A ROOF BOLT CASE NOT DECIDED UNTIL 090189
EMPLOYEE WAS PLACING BLOCK UNDER A PALLET OF ROCK DUST, WHEN THE PALLET BROKE AND FELL ON HIS RIGHT HAND.
ROOF FALL ABOVE ROOF BOLT ANCHORAGE 0 ENTRY OF 1 LEFT AT STATION 5823. THE FALL WAS 6'-8' HIGH X 80' LONG X 20' WIDE. THE AREA HAD BEEN SUPPORTED BY 4' RESIN BOLTS.
ROOF FALL ABOVE ROOF BOG ANCHORAGE IN #3 ENTRY ADN X-CUT 3-4 IN D MAINS. THE FALL STARTED 100' INBY STATION 9830. THE FALL WAS 6' HIGH X 20' WIDE X 60' LONG. THE AREA HAD BEEN SUPPORTED BY 4' RESIN BOLT.
ROOF FALL ABOVE ROOF BOLT ANCHORAGE,STARTING 17+10 #1 ENTRY AND PROCEEDING INBY FOR 120' AND IN THE X-CUT 1-2 ENTRY FOR 55'.THE FALL WAS 20' WIDE HEIGHT UNKNOWN.THE AREA HAD BEEN SUPPORTED BY 4'RESIN BOLTS AND PARTIALLY REBOLTED WITH 6' INSTALL II BOLTS.
ROOF FALL ABOVE BOLT ANCHORAGE IN #3 ENTRY AT 17+75/ THE FALL EXTENED INBY TOWARD THE FACE FOR AN UNKNOWN DISTANCE. THE FALL IS 20' WIDE AND ABOVE THE ROOF BOLTS. THE AREA HAD BEEN SUPPORTED B Y 4' RESIN BOLTS.
EMPL GOT PIECE OF RUST IN RIGHT EYE.HE ISNT SURE HOW OR WHEN IT HAPPENED.
EMPLOYEE LIFTED A PIECE OF ROCK OFF OF THE MINER. THE ROCK BROKE IN HALF AND CUT HIS LEFT 2ND AND 3RD FINGERS.
EMPL WALKING WHEN STEPPED ON CABLE AND SPRAINED HIS RIGHT KNEE.
RF FALL ABOVE ANCH. 3 ROOM OF B-2 OUTBY 2 AND 85. FALL 150' L X 20' W X 6'-8'H FALL EXTNEDED IN X-CUTS R AND LFT AREA SUPPORTED BY RESIN BOLTS.
ROOF FALL ABOVE ROOF BOLT ANCHORAGE B-1 #2 ROOM H 61 TO 2/20. FALL WAS 20'WIDE X 5-6'HIGH X 60'LONG.ROOF HAD BEEN SUPPORTED WITH 4' RESIN BOLTS.
EMPL TRIPPED OVER MINER CABLE & FELL ON RIGHT WRIST FRACTURE.
ROOF FALL ABOVE ROOF BOLT ANCHORAGE #6 ENTRY OF 2 LEFT AT 15+85 THE FALL WAS 10' HIGH X20' WIDE X55' LONG.THE AREA HAD BEEN SUPPORTED WITH 4' RESIN BOLTS.
EMPL PERFORMING NORMAL DUTIES OPERATING MINER AND MOVING PUMPS.FOLLOWING DAY DEVELOPED BACK PAIN NO SPECIFIC INCIDENT.
EMPLOYEE WAS WALKING,HE STRUCK HIS FACE ON A ROOF BOLT MAT.
WHEN LIFTING A RIPPER CHAIN IDLER IT SLIPPED AND HIT HIS 3RD FINGER LEFT AHND.
ROOF FALL ABOVE ROOF BOLT ANCHORAGE FACE OF #12 ROOM OFF LEFT RIGHT THE SIZE OF THE FALL IS 5 FEET HIGH, 20 FEET WIDE, 24 FEET WIDE. THE AREA HAD BEEN SUPPORTED BY RESIN BOLTS.
ELEVATOR DOWN FROM 3;05 TO 4;05 DUE TO FAULTY DOOR SWITCH HOWEVER THE ELEVATOR COULD BE OPERATED MANUALLY.
EMPL USING TROWEL TO APPLY B-BOND TO WALLS.AT END OF SHIFT RIGHT WRIST WAS SORE.NOT REPORTED UNTIL 5-11-89.
ROOF FALL ABOVE BOLT ANCHO;R. 1 ENTRY OF Z LEFT AT 8+ 00 AND EXTENDING OUTBY FOR 90'L, 20'W, 4-6' H. AREA BEEN SUPP BY 4'RESIN BOLTS .
LOADING RAIL ONTO SUPPLY CAR AFTER LIFTING RAIL ON CAR WITH 3 OTHER MEN RAIL SLID OFF ONTO BO;TTOM PINCHING FINGER BETWEEN RAIL AND BAR USING TO LIFT RAIL WITH.
ROOF FALL ABOE BOLT ANCHORAGE 70' INBY STATION AREA HAD BEEN SUPP BY 4'RESIN BOLTS AND STRAPS FALL WAS 70' L, 8'H. 20W.
ROOF FALL ABOVE ROOF BOLT ANCHORAGE AT 1 + 80 #^ ROOOMOF 1 BUTT AREA BEEN SUPP. BY 4 ' RESIN BOLTS STRAPS FALL WAS 50'L, 8'H, 20'W.
ROOF FALL ABOVE BOLT ANCHORAGE 2 ENTRY OF 2 LEFT AT 8 & 75 THE FALL WAS 60 FT LONG X 20 FT WIDE X 4-6FT HIGH. THE AREA WAS SUPPORTED WITH 4 FT RESIN AND 6 FT INSTALL II BOLTS AND STRAPS.
ROOF FALL AVEOVE ROOF BOLT ANCHORAGE IN 9TH PANEL OF 1 LEFT ROOMS AT 5+11 OF #4 ROOM AND 4+8S #3 ENTRY THE FALL WAS 50'L 20'W 8'H THE AREA HAD BEEN SUPPORTED WITH 4' RESIN BOLTS AND MATS
EMPLOYEE WAS LIFTING A BATTERY COVER OFF A BUS WITH ANOTHER EMPLOYEE THE COVER CAUGHT & THE EMPLOYEE JERKED ON CAUSING A SPRAIN TO HIS LEFT SHOULDER
EMPLOYEE STEPPED OFF OF A SUPPLY CAR ONTO A SLEDGE HAMMER CAUSING HIM TO SPRAIN HIS ANKLE
EMPLOYEE WAS LOWERING BOLTER HEAD AS HE WAS DOING SO IS FOOT SLIPPED ON LOOSE COAL CAUSING BOLTER HEAD TO STRIKE RT LEG
ROOF FALL ABOVE ROOF BOLT ANCHO;RAGE AT 24 AND 66 34 ENTY A OF 1 LEFT FALL WAS 20' X 6' -10' HIGH AREA HAD BEEN SUPP BY 4' RESIN BOLTS AND STRAPS.
ROOF FALL ABOVE ROOF BOLT ANCHORAGE IN #8 PANEL OF B-1 ROOMS ROOF FALL OCCURRED IN X-CUT 4-5 AT 2+11 FOR 20 FT WIDE X 7 FT - 10FT HIGH X 20 FT WIDE THE FALL CONTINUED IN #4 ROOM FOR AN ADDITIO NAL 55 FT INBY THE AREA HAD BEEN SUPPORTED WITH 4 FT RESIN BOLTS AND ROOF MATS
EMPLOYEE WAS BARRING DOWN LOOSE MATERIAL. THE MATERIAL STRUCK THE CONVEYOR BELT, BOUNCING AND STRUCK INJURED'S LEFT HAND.
EMPLOYEE WAS USING A PUMP JACK AND BAR TO LIFT, WHEN THE BAR SLIPPED OUT OF THE JACK CATCHING HIS FINGER BETWEEN THE BAR AND MINE BOTTOM.
EMPLOYEE WAS CUTTING A PLANK WITH A SAW. WHEN SAW CUT THRU EMPLOYEE STRUCK HIS FINGER AGAINST PLANK.
ROOF FALL ABOVE ROOF BOLT ANCHORAGE AT 29+16 1 LEFT. FALL WAS 20' X 20' X 5' HIGH. THE ROOF WAS SUPPORTED WITH 4' RESIN BOLTS WITH MATS.
EMPLOYEE WAS UNLOADING A CANOPY FROM A SUPPLY CAR WHEN HE CAUGHT HIS FINGER BETWEEN THE SUPPLY CAR AND CANOPY.
EMPLOYEE WAS DRILLING A HOLE TO INSTALL A ROOF BOLT WHEN A ROCK FELL FROM THE ROOF STRIKING HIS LEFT ANKLE.
1988 · 36 incidents
THE INJURED WAS BENDING A 4' REBAR AND FELT PAIN IN BACK.
EMPL TRIPPED OVER MINER CABLE AND FELL STRIKING HIS HAND ON MINER
ROOF FALL WAS FOUND ON 110188 AT 330 AM IN #11 ROOM OF B-1 FALL WAS 200FT.LONG X 20FT.WIDE X4-S FT.HIGH AREA WAS S UPPORTED BY 4FT.RESIN BOLTGS
EMPLOYEE WAS REMVING A ROOF BOLT FROM TOP OF BOLTER WHEN IT CAUGHT ANOTHER ROOF BOLT PULLING IT OFF AND STRIKING HIS CHEEK.
BELT SUPPORT CHAIN BROKE STRIKING HIS FINGER.
EMPLOYEE WAS DRILLING A HOLE WHEN A PIECE OF MATERIAL FELL STRIKING HIS BACK.
ROOF FALL ABOVE ANCHORAGE OUTBY AREA OF 1 LT. 3 ENTY STATION 2499. FALLIS 20' W.. X 20' L. X 4'-6' H. CONDITION FOUND ON 10-1488 AT 10:50 AM
EMPL WALKIGN WHEN HE TRIPPED AND FELL ON HIS RIGHT HAND.
ROOF FALL ABOVE ROOF BOLT ANCHORAGE APPROX 30 FT LONG X 20 FT WIDE X 6 FT HIGH LOCATED IN 5 LEFT 90 FT INBY #21 ROOM OFF SPAD 4776
AS THE EMPLOYEE WAS LIFTING ROOF BOLTS HE HURT HIS UPPER BACK.
INJURED HIT HEAD ON A ROOF BOLT WHEN OPERATING SCOOP
THE INJURED WAS TRAMMING A CONTINUOUS MINER AWAY FROM A FINAL PUSHOUT STUMP. A ROOF FALL OCCURRED. INJURED RECEIVED BRUISED RIBS WHEN MINER CANOPY STRUCK ROOF. CUTTER HEAD WAS IN RAISED POSITI ON WHEN FALL OCCURRED. FALL IS APPROX. 8' HIGH IN PILLAR EXTRACTION AREA OF #56 BLOCK.
THE INJURED WAS REPOSITIONING A POGO STICK USED TO HANG LINE CANVAS. WHEN HE REMOVED THE POGO STICK, A PIECE OF ROOF 8" X 8" X 4" THICK FELL STRIKING HIS ELBOW.
EMPLOYEE WAS GETTING OUT OF LOCOMOTIVE AFTER MOVING IT WHEN HE SLIPPED STRIKING RIGHT KNEE AGAINST FRAME OF LOCOMOTIVE.
THE INJURED STATED THAT WHILE PULLING MINER CABLE HE TWISTED HIS KNEE.
INJURED WAS SHOVELING COAL FROM RIB WHEN HE INJURED HIS LEFT WRIST INJURED STATED MINE BOTTOM IS UNEVEN. BOTTOM CAUSING SPRAINED WRIST.
INJURED WAS KNEELING AND PREPARING TO BOLT WHEN HE FELT HIS KNEE GIVING OUT.
INJURED WAS TRAMMING SHUTTLE CAR TO THE MINER IN 5 ENTRY THE MINER CABLE WAS HUNG FROM THE ROOF ACROSS THE ENTRY AS HE WAS GOING UNDER THE CABLE IT STRUCK HIS HEAD.
THE INJURED WAS GRADING MINE BOTTOM A METAL POST WHICH IS MOUNTED ON THE MINER BEHIND OPERATOR COMPARTMENT CAUGHT AGAINST ROOF HE RECEIVED A BACK INJURY WHEN THE MINER BOUNCED.
INJURED WAS LOADING ROOF BOLTS PLATES & RESIN FROM SHUTTLE CAR TO ROOF BOLTER AREA WHERE INJURY OCCURED IS LOW. INJURED STATED HE STRAINED HIS BACK.
INJURED WAS OPERATING SHUTTLE CAR ON PILLAR SECTION. HEIGHT IS APPROX 8'. PIECE OF RIB ROLLED OFF STRIKING HIS RIGHT SHOULDER. EMPL SWITCHED OUT IN CROSSCUT WAITING FOR ANOTHER SHUTTLE CAR TO GO PAST WWHEN RIB FELL.
INJURED STRAINED BACK WHILE LIFTING 8' LONG POST.
ROOF FALL IN BLEEDER OF 1 SOUTHEAST LOCATION IS LAST CUT THRU BETWEEN #18 AND #19 ENTRY 5 FEET HIGH 20 FEET WIDE 15 FEET LONG.
THE INJURED WAS LIFTING A BUNDLE OF ROOF BOLT PLATES ON BOLTER WHEN HE TWISTED HIS BACK.
INJURED WAS HOLDING INSTALL II BOLT IN LEFT AHND AT COUPLING JOINT WHEN HE ACCIDENTLY USED THRUST LEVER INSTEAD OF THE ROTATIOMN LEVER.
THE INJURED WAS BENDING A 4' REBAR AND FELT PAIN IN BACK.
INJURED WAS CARRYING A FULL BUCKET 5 GALLON OF GREASE FROM THE FACE AREA AND STRUCK HIS HEAD ON A LOW HANGING BOLT AND SKIN.JAMMED NECK.
THE INJURED WAS HELPING TO REENTER A MINER CABLE. WHILE HOLDING WATERLINE, ANOTHER EMPLOYEE WAS USING A HAMMER TO FREE PACKING GLAND NUT. A PIECE OF HAMMER BROKE OFF AND BECAME EMBEDDED IN RI GHT INDEX FINGER. PIECE OF STEEL WAS REMOVED AT LEE HOSPITAL.
INJURED STATED THAT HE WAS MOVING 100 LB BAGS OF CALCIUM WHEN HE FELT PAIN IN BACK. ON MONDAY 8/29/88 HE FELT FURTHER PAIN AFTER LIFTING POST. INJURED DID N OT REPORT INCIDENT TO ANYONE UN TIL 8/31/88.
A PORTION OF A COUNTER BALANCE GUIDE WHEEL BROKE. THE WHEEL WOULD TURN INDICATING THE BEARING WAS OPERABLE THE ELEVATOR WA> TAKEN OIUT OF SERVICE DUE TO THE NOISY GUIDE ROLER.
THE INJ. WAS HANGING CANVAS. HT. IS APPROX. 9FT WHILE HANGING THE CANVAS A STEP LADDER HE WAS USING KICKED OUT CAUSING HIM TO FALL. INJ. RE. A CUT ON THE CHIN WHICH REQUIRED 5 SUTURES. THE I NJ STRUCK HIS CHIN ON A CROSSBAR WHICH WAS IN T HE AREA.
ROOF FALL ABOVE BOLT ANCHORAGE 0-5 FEET HIGH 12X16' WIDE 4' RESIN BOLTS WITH MATS #2 ENTRY 5 LEFT NEAR SPAD 4774
THE INJURED WAS MOVING A CABLE OFF ROADWAY WHEN A PICE OF ROCK 13"X15"X5" THICJ FELL STRIKING HIS HEAD AND BACK.THE ROCK FELL FROM BETWEEN THE RIB AND A ROOF BOLT.
THE IN. WA> RE ENTERING A ROOF BOLTER TRAILING CABLE. WHILE REACHING UNDER THE MACHINE ATTACHING THE CABLE TO A UNCTION BOX HE PULLED MUSCLE IN NECK. THE INJ. WEN TO A DR. ON 8-23-88 AND BEG
THE INJURED THREW A POST ALONG THE RIB. THE POST STRUCK THE RIB AND ONE END KICKED BACK STRIKING HIS RIGHT LEG. (BRUISED LEG).
INJURED WAS WALKING (CRAWLING TO CABLE BRIDGE CONVEYOR) & EXPERIENCED PAIN IN RT.SIDE OF BACK