PIECE OF DRAW ROCK FELL & CAUGHT LEFT SIDE OF HIP AND CRUSHED PELVIS.
No 1 Coal
Watch this mine
Email me when a new MSHA incident is filed at No 1.
- Fatalities
- 1
- Total incidents
- 27
- Years on record
- 1998–2000
- Latest incident
- Jul 2000
ⓘ
This rate is recorded citations divided by MSHA inspection hours, per 100 hours. It reflects inspection effort, not mine size or production.ⓘ
Citations per million reported employee-hours. Rates begin in 2000, when MSHA's quarterly employment data starts; earlier incidents are counted but cannot be rate-adjusted. Quarters under 100,000 reported hours are greyed: too few hours for a stable rate.| Quarter | Hours worked | Citations | S&S | Per 1M hrs |
|---|---|---|---|---|
| 2000 Q3 | 7,251 | 7 | 5 | 965.4 |
| 2000 Q2 | 12,745 | 2 | 0 | 156.9 |
| 2000 Q1 | 15,031 | 8 | 3 | 532.2 |
Fatalities at this mine
1 recordedReportable incidents
26 on file (excluding fatalities above)2000 · 5 incidents
ROOF FALL IN PRIMARY ESCAPEWAY 1000 FT OUT BY FACE AREA, ONE BREAK IN BY SPAD 59. TOP WAS SUPPORTED WITH 4 FT FULLY GROUTED GLUE BOLTS. TOP WAS GATHERING MOISTURE. TOP FELL FROM 1 TO 5 FT HIGH . FALL WAS 18' WIDE 5' HIGH, 70' LONG.
BACKING BOLTER BACK TOWARD SPAD 108 & GOT FOULEDAGAINST RIB.
PUSHING BULB BACK IN JOY 21 S-CAR. LENSE BUSTED & CUT THUMB ON RIGHT HAND.
DUMPED SHUTTLE CAR. WAS GOING BACK TO MINER. TURNED, LEFT HANDED & CAUGHT LEFT HAND AGAINST RIB.
GETTING OUT OF DECK OF SCOOP HAND SLIPPED AND RIBS HIT LIGHT AND FRAME. BRUISED RIBS ON LEFT SIDE.
1999 · 14 incidents
ROOF FALL 2 BREAKS INBY SPAD 161, IN NO. 6 ENTRY, ROOF FELL IN FROM 20' OUTBY RT SIDE OF SOLID COAL IN 7 ENTRY STRAIGHT ACROSS TO WITHIN 30' OF BELTLINE IN NO. 4 ENTRY. LENGTH OF FALL 160', 20 ' WIDE, 8 TO 10' HIGH. DEVELOPED 11-4-98. BOLTEDWITH 4' FULL GROUT GLUE BOLTS. THERE WAS TIMBER AND CRIBS SET WHERE TOP FELL.
GETTING OUT OF SCOOP PUT HANDS ON TOP OF CANOPY TO PULL SELF OUT, FEET SLIPPED UNDER HIM & FELL ON BACK. WENT TO DR 8/26/99
ROOF FALL IN INTAKE BIG HORSESBACK FELL ONE BRK INBY SPAD 306 DRD NOT RESTRICT AIR WAY FALL WAS 18X40X7FT HIGH. TOP WAS BOLTED WITH 4FT FULLY GROUTED RESIN BOLTS. WATER WAS COMING THRU TOP 140 0' OUTBY FACE DEVELOPED 2/10/99
ROOF FALL FROM LEFT SIDE OF NO.3 ROADWAY ALL THE WAY TO LEFT PILLAR IN NO. 1 WATER HAD OSTERIATED ROOF FALL WAS 6 FT HIGH. HAD RETURN RESTRICTED OPENED UP NO. 1 ENTRY. FALL WAS 1 BRK OUTBY SPA D 80 IN THE RETURN. 100 X 18 X 6.
A ROOF FALL RIB HAD CUTTER ON LEFT SIDE WE HAD BEEN TIMBERING IT. TOP FELL ABOUT 90' X 18' X 5'.1 BREAK OUTBY SPAD 322 IN NO. 4 ENTRY(NUETRAL). DID NOT EFFECT TRAVELWAY OR VENTILATION. DEVELOP ED AREA 03/22/99. BOLTED WITH 4FT. FULL GROUTED GLUE BOLTS. SOME WATER WAS COMING THRU THE TOP.
UNINTENTIONAL ROOF FALL IN A NEUTRAL AREA.
ROOF FALL IN INTAKE (PRIMARY) APPROX. 2400' OUTBY FACE AREA. AT SPAD 162 IN NO. 6 ENTRY. FALL WAS 20' X 20' X 5'. AREA HAD BEEN BOLTED WITH 4' FULLY GROUTED ROOF BOLTS. WATER WAS COMING THRU T OP. AREA HAD BEEN TIMBERED ON BOTH SIDES DOWN TO 14' ROADWAY.
ROOF FALL ABOUT 30' LONG, 20' WIDE, & ABOVE ROPOF SUPPORT 4'. ABOUT 1500' OUTBY FACK IN RETURN LEF OF SPAD 181 IN XCUT. WATER WAS COMING THRU TOO. DID NO RESTRICT AIR OR TRAVELWAYS. TIMBERED O FF. BOLTED WITH 4' FULLY GROUTED GLUE BOLTS.
DID NOT GO TO DR. UNTIL 4-19-99. WAS PULLING MINER CABLE OUT OF ROADWAY.
LOADING TRAM MOTOR FOR MINER ON MANTRIP.
HAD A ROOF FALL AT BREAK 39 DISCOVERED BY PRE-SHIFT EXAMINER. FALL FELL FROM SPAD 179 ACROSS FOR 80, 18 X 20' WIDE, 2 TO 6 1/2 HEIGHT. RETURN ENTRIES.
LIFTING BELT ON BELTMOVE PULLED RIGHT SHOULDER DID NOT GO TO DR UNTIL 4-15-99.
OCCUPATIONAL ILLNESS-CARPUL TUNNEL.
WAS SHOVELING COAL WHEN THROWING COAL ON BELT, TWISTED BACK.
1998 · 7 incidents
FELL ON ICE, HURT LOWER BACK & LEGS. REPORTED LATE, EMPLOYEE SEEN DOCTOR.
PUSHING AND PULLING LEVERS ON SCOOP. (REPORTED ON 12/3/98 ABOUT INJURY BUT DID NOT SEE DOCTOR UNTIL 1/27/99.
BOLTING TOP DOWN ON KNEES, HURT LEFT KNEE. DID NOT GO TO DR. UNTIL 2-5-99.
DRAGGING A OXYGEN BOTTLE & HURT BACK
WHILE LIFTING TIMBER AND PUMP, INJURED LOWER BACK & RIGHT SHOULDER.
SMALL PIECE OF ROCK FELL ON INJURED'S HAND, BRUISING THE HAND.
WATER WAS VCOM,ING OUT OF TOP, WEAKENED ROOF & FELL IN INTERSECTION. AREA THAT FELL WAS 18-20' WIDE, 28' LONG & 6 1/2-7' HIGH.