Mining Incidents

Smith Underground No 1 Coal

Lodestar Energy Inc · Underground
Controlled by Iracoal Incorporated
Providence, Webster County, KY  ·  Abandoned and Sealed
MSHA Mine ID: 1516020

Smith Underground No 1 has $55 in proposed MSHA penalties and $0 outstanding across 0 contested dockets, plus health sampling and the full incident record.

Watch this mine

Email me when a new MSHA incident is filed at Smith Underground No 1.

Fatalities
0
Total incidents
200
Years on record
1996–1999
Latest incident
Apr 1999
Compliance record
MSHA citations since 2000
1
citations
0
significant & substantial
$55
proposed penalties
$55
paid to date
100% of proposed penalties paid to date, a $0 gap.
Source: MSHA violations data, updated weekly.
Inspection activity
MSHA inspections since 2000
3
inspections on record
103
inspection hours
n/a
citations per 100 inspection hours
This rate is recorded citations divided by MSHA inspection hours, per 100 hours. It reflects inspection effort, not mine size or production.
Rate withheld: 103 inspection hours is too few for a stable rate. A minimum of 1,000 inspection hours is required.
Source: MSHA inspections data, updated weekly.

Smith Underground No 1 has $55 in proposed MSHA penalties and $0 outstanding across 0 contested dockets.

Penalty disposition
Differences between proposed and paid penalties reflect both settlements and conference reductions and amounts still owed. Outstanding is the balance currently owed.
$55
proposed penalties
$55
current assessed
$55
paid to date
$0
outstanding
1 assessments are final orders; 0 contested dockets.
As of the most recent assessment on 2000-08-23.
Source: MSHA assessed-violations and conference/litigation data, updated weekly.
Quarterly safety rates
Citations per million reported employee-hours. Rates begin in 2000, when MSHA's quarterly employment data starts; earlier incidents are counted but cannot be rate-adjusted. Quarters under 100,000 reported hours are greyed: too few hours for a stable rate.
Citations per million employee-hours, as reported to MSHA
Quarter Hours worked Citations S&S Per 1M hrs
2000 Q4 0 0 0
2000 Q3 0 1 0
No fatalities recorded at this mine.

Reportable incidents

200 on file

1999 · 5 incidents

April 26, 1999 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE FIRST SOUTH PANEL AT SPAD 2 AND 25 IN NO 1 ENTRY. THIS AREA WAS ABANDONED IN JAN 1999. THE DIMENSIONS OF THEROOF FALL ARE 25' LONG 17' WIDE AND 8' HIGH.

March 30, 1999 KY · Coal SLIP OR FALL OF PERSON
Lodestar Energy Inc · Fall onto or against objects

EE WAS GETTING OUT OF SCOOP PLACED FOOT ON SCOOPSEAT, SLIPPED CAUSING HIM TO SIT DOWN HARD ON THE STEEL RIM OF SEAT TOP BRUISE BUTTOCKS & HURTING HIS BACK & LEG

March 22, 1999 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE 1ST SOUTH PANEL AT SPAD 2+80 IN NO. 3 ENTRY, APPROX 2700' FROM THE WORKING SECTION IN AN ABANDONED PANEL. THE DIMENSIONS OF THE FALL AREA 18' LONG, 18' WIDE AND 12' HIGH.

January 22, 1999 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURED IN THE 1ST EAST PANEL AT SPAD 5 + 60 BETWEEN NO 4 AND NO 5 ENTRIES. THE DIMENSIONS OF THE FALL ARE 35' X 17' X 7' HIGH.

January 18, 1999 KY · Coal roof bolter, rock bolter, pinner, mobile roof support operator (mrs) HANDLING OF MATERIALS
Lodestar Energy Inc · Struck by flying object

EMPLOYEE WAS PICKING UP BOARDS FROM A PALLET OF BOARDS IN A SCOOP BUCKET WHEN A BAND HOLDING THE BOARDS, CAME UP AND HIT EMPLOYEE IN LEFT EYE.

1998 · 78 incidents

October 30, 1998 KY · Coal timberman MACHINERY
Lodestar Energy Inc · Struck by falling object

EE WAS DRIVING CAP BOARDS WITH RIGHT HAND WHEN A PIECE OF ROCK FELL AND STRUCK HIM ON THE LEFT HAND, CUTTING TWO MIDDLE FINGERS.

October 26, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE EAST MAIN PARALLELS AT SPAD 3+50 IN NO. 1 ENTRY. THE DIMENSIONS OF THE FALL AREA 18' LONG, 18' WIDE, AND 10' HIGH. THE FALL IS APPROX 4000' FROM THE UNIT AND WI LL NOT BE CLEANED UP.

October 5, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED AT SPAD 27 & 20 IN NO.3 ENTRY IN THE 2ND EAST MAWS. THE DIMENSIONS OF THE FALL AREA 25' LONG, 17' WIDE, 7' HIGH.

October 5, 1998 KY · Coal roof bolter, rock bolter, pinner, mobile roof support operator (mrs) FALL OF ROOF OR BACK
Lodestar Energy Inc · Struck by falling object

EE WAS OBSERVING TOP IN AREA (NO.3 ENTRY) AND ROCK FELL OUT KNOCKING HARD HAT OFF AND CUTTING TOP OF HEAD

October 4, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE 2ND EAST MAWS AT SPAD 21 & 80 IN NO.2 ENTRY. THE DIMENSIONS OF THE FALL ARE 20' LONG, 17' WIDE, 13' HIGH.

September 24, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN TEH EAST MAIN PARALLEL ENTRIES AT SPAD 23+10 IN NO. 9 ENTRY. THE DIMENSIONS OF THE FALL ARE 20' LONG, 17' WIDE DN 9' HIGH. THE FALL WILL NOT BE CLEANED UP. THE FALL IS 4000' OUTBY THE UNIT.

September 22, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED INBY SPAD 4+50 IN THE 2ND NORTH MAINS IN NO. 7 ENTRY. THE DIMENSIONS OF THE THE FALL ARE 16' LONG, 17' WIDE AND 8' HIGH. THE FALL IS 2900 OUTBY THE UNIT AND WILL NOT B E CLEANED UP.

September 21, 1998 KY · Coal roof bolter, rock bolter, pinner, mobile roof support operator (mrs) MACHINERY
Lodestar Energy Inc · Struck by falling object

EMPLOYEE WAS DRILLING HOLE TO INSTALL ROOF BOLT WHEN A PIECE OF ROCK FELL AND STRUCK HIM ON THE LEFT CHEEK.

September 13, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN TEH 2ND NORTH MAINS AT SPAD 1+80 IN NO. 4 ENTRY. THE ROOF FELL ON TOP OF ARCHES ON THE BELTLINE. THE SIZE OF THE FALL IS 8' LONG, 17' WIDE AND 6' HIGH.

September 12, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURED IN THE 2ND EAST MAINS ATSPAD 19+10 IN NO.2 ENTRY. THE DIMENSIONS OF THE FALL ARE 20'L, 17'WIDE AND 13' HIGH. THE FALL IS300' OUTBY THE FACES AND WILL NOT BE CLEANED UP

September 12, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE 2ND EAST MAINS AT SPAD 14+60 IN NO. 2 ENTRY. THE DIMENSIONS OF THE FALL ARE 18' LONG 18' WIDE AND 13' LONG. THE FALL IS 900' OUTBY THE UNIT AND WILL NOT BE CLEA NED.

September 8, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN TH2 2ND EAST MAINS AT SPAD 18+20 IN NO. 5 ENTRY. THE DIMENSIONS OF THE FALL ARE 20' LONG, 20' WIDE 12' HIGH. THE FALL IS 350' FROM THE FACE 180' AWAY OUTBY THE DUMP ING POINT.

September 5, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE EAST MAIN PARALLEL AT SPAD 24+90 IN NO. 3 ENTRY. THE DIMENSIONS OF THE FALL ARE 20' LONG, 24' WIDE, 13' HIGH. THIS FALL IS 4000' OUTBY THE UNIT.

September 1, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE 2ND NORTH MAIN ENTRIES AT SPAD 1+80 IN NO. 4 ENTRY. THE DIMENSIONS OF THE FALL ARE 40' LONG, 17' WIDE, AND 14' HIGH. THE FALL IS 1600' OUTBY THE UNIT IN THE BEL T ENTRY AND WILL BE CLEANED UP.

August 30, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE 2ND EAST MAINS AT SPAD 20+00 IN NO. 5 ENTRY. THE DIMENSIONS OF THE FALL ARE 18' WIDE, 18' LONG, 12' HIGH.

August 24, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE EAST MAINS AT SPAD 3+75 IN NO. 1 ENTRY. THE DIMENSIONS OF THE FALL ARE 17' LONG, 17' WIDE AND 8' HIGH.

August 23, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE 2ND NORTH MAINS AT SPAD 9+19 IN NO. 6 ENTRY. THE DIMENSIONS OF THE FALL ARE 20' LENGTH, 18' WIDE AND 13' HIGH.

August 21, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN 2ND NORTH MAINS IN BNO 3 ENTRY AT SPAD 1 + 80. THE DIMENSIONS OF THE FALL ARE 20'LONG,17'WIDE, 13'HIGH. THE FALL IS 2700' OUTBY THE UNIT.

August 18, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE 2ND NORTH MAINS AT SPAD 8+28 IN NO. 3 ENTRY. THE DIMENSIONS OF THE FALL AREA 65' LONG, 17' WIDE AND 12' HIGH. THIS FALL IS 2000' OUTBY THE UNIT.

August 12, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE 2ND NORTH MAINS AT SPAD 0+90 IN NO.2 ENTRY. THE DIMENSIONS OF THE FALL ARE 20'L, 18'W, 12'H. THE FALL IS 2600 OUTBY THE UNIT

August 8, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURED IN THE 2ND EAST MAINS INBY SPAD 13+80 IN NO.1 ENTRY. THE DIMENSIONS OF THE FALL ARE 30'L, 17'W, 8'H. THE FALL IS 250' OUT OF THE UNIT

August 6, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE 2ND EAST MAINS INBY SPAD 7 + 40 IN NO. 1 ENTRY. THE DIMENSIONS OF THE FALL ARE 25' LONG, 17' WIDE, 9' HIGH. THE FALL IS 1000' OUTBY THE UNIT.

August 4, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE EAST MAIN PARELLELS AT SPAT 1+40 IN NO.2 ENTRY. THE DIMENSION OFTHE FALL ARE 60'L, 18'W,8'HIGH. THE FALL IS 4800'OUTBY THE WORKING SECTION.

July 23, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN 2ND NORTH MAIN ENTRIES AT SPAD 2+70 IN HO. 2 ENTRY. THE DIMENSIONS OF THE FALL ARE 20' LONG,M 17' WIDE AND 12' HIGH. THE FALL IS APPROX. 2200' OUTBY THE UNIT.

July 21, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCVURRED IN THE EAST MAIN PARALLEL ENTRIES AT SPAD 14+70 BETWEEN NO. 3 AND NO. 4 ENTRIES. APPROX. 4000' OUTBY UNIT IN INTAKE AIR COURSE. THE DIMENSIONS OF THE FALL AREA 70' LO NG, 17' WIDE AND 6' HIGH.

July 10, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE 2ND NORTH AT SPAD 6_37.9 IN THE NO. 3 ENTRY. THE DIMENSIONS OF THE FALL ARE 20' LONG BY 20' WIDE AND 13' HIGH. FALL IS 1400' OUTBY WORKING SECTION.

July 5, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURED IN THE 2ND EAST MAINS ENTRIES AT SPAD 2 + 40 IN THE NO 2 ENTRY. THE DIMENSIONS OF THE FALL ARE 20' LONG BY 17' WIDE AND 13' HIGH. FALL IS 1200' OUTBY WORKING SECTION WH ICH WAS IDLE AT TIME OF FALL.

June 26, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE EAST MAINS AT SPAD 23+70 IN NO. 3 ENTRY. THE DIMENSIONS OF THE FALL ARE 10' LONG, 17' WIDE, 8' HIGH. THE FALL IS8200' OUTBY THE SECTION AND WILL NOT BE CLEANED UP.

June 19, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED INT HE 2ND NORTH MAIN ENTRIES AT SPAD 5+40 IN NO. 4 ENTRY. THE DIMENSIONS OF THE FALL ARE 75'L, 17'W AND 10' HIGH.

June 18, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURED IN THE NO.1 ENTRY AT THEPORTAL OF THE MINE. THE DIMENSIONS OF THE FALL ARE 25'L, 17'W,AND 5'HIGH.

June 9, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE SECOND EAST MAINS AT SPAD 13+00 IN NO. 5 ENTRY. THE DIMENSIONS OF THE FALL ARE 48' LONG, 17' WIDE 14' HIGH.

June 8, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE SECOND EAST MAINS INBY SPAD 11+40 IN NO. 2 ENTRY. THE DIMENSIONSOF THE FALL ARE 60' LONG 17' WIDE 8' HIGH.

June 1, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE 2ND EAST MAINS INBY SPAD 6 & 60 IN NO.3 ENTRY. THE DIMENSIONS OF THE FALL ARE 14'LX17'W AND 6' H. THE FALL IS IN A SLIP AREA 630' OUTBY THE FACES.

May 31, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURED IN THE 2ND MAIN EAST AT SPAD 5 & 80 IN THE NO.6 ENTRY. RETURN THE DIMENSIONS OF THE FALL ARE 25'L X 17'W X 12' HIGH. FALL IS 650' OUTBY THE WORKING SECTION. FALL OCCURE D IN A PROJECTED SLIP AREA.

May 27, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF ALL HAS OCCURRED IN THE EAST MAIN PARALLEL AT SPAD 25+80 IN THE NO. 4 ENTRY. THE DIMENSIONS OF THE FALL AR 20' LONG 17' WIDE AND 12' HIGHFALL WAS 2800 FEET FROM WOKING FACE. FALL WILL N OT BE CLEANED UP. SUPPORT HAS BEEN ADDED TO ALL ADJACENT ENTRYS.

May 18, 1998 KY · Coal shuttle car operator, mantrip operator, ramcar operator, rail runner, buggy operator SLIP OR FALL OF PERSON
Lodestar Energy Inc · Over-exertion (Not Elsewhere Classified)

EE WAS BUILDING ARCHES IN #5 ENTRY WHEN HE SLIPPED ON A ROCK AND TWISTED HIS RIGHT HIP.

May 18, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE 2ND EAST MAINS AT SPAD 5+80 IN NO. 5 ENTRY. THE DIMENSIONS ON THE FALL ARE 18' LONG, 18' WIDE' AND 12' HIGH. THE ROOF FALL WAS 100' FROM THE FACE AND WILL BE CL EANED UP AND ARCHED.

May 6, 1998 KY · Coal roof bolter, rock bolter, pinner, mobile roof support operator (mrs) MACHINERY
Lodestar Energy Inc · Struck by falling object

EE WAS INSTALLING ROOF BOLT AND WAS SITTING HIS WRENCH INTO THE POT OF THE ROOF BOLTER WHEN A PIECE ROCK FELL AND STRUCK HIS RIGHT RING FINGER.

April 28, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS IN THE EAST MAIN PARALLELS AT SPAD 20 & 40 IN NO.4 ENTRY. THE DIMENSIONS OF THE FALL AREA 40' LONG, 17' WIDE AND 10' HIGH. THE FALL IS 800' OUTBY THE WORKING SECTION.

April 27, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN NO.3 ENTRY IN THE EAST MAIN PARALLELS AT SPAD 48 & 29. THE DIMENSIONS OF THE FALL ARE 20' LONG, 17' WIDE, 12' HIGH. THE FALL IS 2400 OUTBY THE SECTION.

April 24, 1998 KY · Coal roof bolter, rock bolter, pinner, mobile roof support operator (mrs) MACHINERY
Lodestar Energy Inc · Struck by falling object

EE WAS DRILLING HOLE IN MINE ROOF TO INSTALL 12' SUPER BOLT. WHEN HE DROPPED THE POT TO PUT A WRENCH ON THE BOTTOM SECTION OF PINNER STEEL, STEEL FELL OUT OF HOLE AND HIT LEFT HAND.

April 23, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE EAST MAIN ENTRY AT CROSSCUT NO. 1 IN NO.2 ENTRY. THE DIMENSIONS OF THE FALL ARE 18' X 18/ X 5'. THE FALL IS 10000' OUTBY AND WILL BE CLEANED UP.

April 23, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE 2ND NORTH ENTRIED AT SPAD 4+50 IN NO. 4 AND NO. 3 ENTRY. THE DIMENSIONS OF THE FALL ARE 110' LONG 17' WIDE AND 10-14' HIGH. THE FALL WILL BE CLEANED UP.

April 23, 1998 KY · Coal roof bolter, rock bolter, pinner, mobile roof support operator (mrs) FALL OF ROOF OR BACK
Lodestar Energy Inc · Struck by falling object

EE WAS STANDING NEXT TO THE ROOF BOLTER MAKING UP PIN, WHEN A PIECE OF ROCK FELL BETWEEN PINS STRIKING HEAD & CUTTING FOREHEAD & INJURING LOWER BACK.

April 13, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE EAST MAIN PARALLELS AT SPAD 72+84 IN NO. 6 ENTRY. THE DIMENSIONS OF THE FALL ARE 18'L, 17'W, & 12'H. UNIT IS BEING MOVED TO ANOTHER LOCATION.

April 13, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE EAST MAIN PARALLELS AT SPAD 73+74 IN NO. 2 ENTRY. THE DIMENSIONSOF THE FALL 17' LONG 17' WIDE AND 12' HIGH.

April 12, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE EAST MAIN PARALLELS AT SPAD 74 & 64 IN NO.7 ENTRY. THE DIMENSIONS OF THE FALL ARE 24" LONG, 17" WIDE, 13" HIGH. UNIT IDLE FOR EASIER HOLIDAY.

April 12, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE EAST MAIN PARALLELS AT SPAD 74 & 64 IN NO.7 ENTRY. THE DIMENSIONS OF THE FALL ARE 24" LONG, 17" WIDE, 13" HIGH. UNIT IDLE FOR EASIER HOLIDAY.

April 7, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF [FALL] HAS OCCURRED IN THE EAST MAIN PARALLELS AT SPAD 51+99 IN NO. 9 ENTRY. THE DIMENSIONS OF THIS FALL ARE 50'L, 17'W, & 12'H. THE FALL IS 2100' OUTBY FACES IN THE LEFT RETURN.

April 6, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE EAST MAIN PARALLELS AT SPAD 71+04 IN NO. 7 ENTRY. THE DINENSIONS OF THE FALL ARE 17'L, 17'W, 15'H. 200' OUTBY THE FACE.

April 5, 1998 KY · Coal beltman, conveyor man, conveyor belt worker, mobile bridge carrierman, feeder operator, conveyor rider HANDLING OF MATERIALS
Lodestar Energy Inc · Struck by... (Not Elsewhere Classified)

EMPLOYEE WAS RAISING BELT UP SO HE COULD INSTALL A BOTTOM ROLLER WHEN THE BOTTOM ROLLER AND HANGER SLIPPED FROM CHANNEL LOCKS AND STRUCK HIS RIGHT THUMB.

April 4, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE EAST MAIN PARALLEL AT SPAD 48+39 IN NO. 7 ENTRY. THE DIMENSIONS OF THE FALL ARE 30'L, 17'W, 12'H. 2000' FROM FACES.

April 2, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE EAST MAIN PARRALLETS AT SPAD 59+34 IN NO. 1 ENTRY. THE DINENSIONS OF THE FALL ARE 18'L, 17'W, & 12'H. 1200' OUTBY FACES.

April 2, 1998 KY · Coal beltman, conveyor man, conveyor belt worker, mobile bridge carrierman, feeder operator, conveyor rider HANDLING OF MATERIALS
Lodestar Energy Inc · Struck by... (Not Elsewhere Classified)

EMPLOYEE WAS PUTTING UP BELT HANGERS AND GOT A PIECE OF COAL IN HIS RIGHT EYE.

March 28, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE EAST MAIN PARRELLS AT SPAD 63+24 IN NO. 2 ENTRY APPROX. 400' OUTBY THE FACES. THE DIMENSIONS OF THIS FALL ARE 20' LONG, 17' WIDE AND 15' HIGH. RETURN ENTRY.

March 27, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE EAST MAIN PARRELLS AT SPAD 66+39 IN NO. 6 ENTRY. THE DIMENSIONS OF THE FALL ARE 30' LONG, 17 1/2' WIDE, 8' HIGH. THE FALL WAS IN THE LAST OPEN CROSSCUT.

March 26, 1998 KY · Coal continuous miner operator, coal mole operator FALL OF ROOF OR BACK
Lodestar Energy Inc · Struck by falling object

EE WAS WAITING TO LOAD A CAR WHEN A PIECE OF ROCK FELL BETWEEN PINS AND STRUCK HIM ON THE RIGHT KNEE.

March 11, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE EAST MAIN PARALLELS AT SPAD 55+59 IN XCUT BETWEEN NO. 6 AND NO. 7 ENTRY.

March 11, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE EAST MAIN PARALLELS AT SPADF 51+09 IN NO. 5 ENTRY, 650' OUTBY FACE. THE DIMENSIONS OF THE FALL ARE 25' LONG, 20' WIDE, AND 12' HIGH.

March 9, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE EAST MAIN PARALLELS OUTBY SPAD 52+89 IN NO. 8 ENTRY. NEUTRAL. 420' OUTBY FACE. THE DIMENSIONS OF THE FALL ARE 35' LONG, 17' WIDE AND 9' HIGH.

March 9, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE EAST MAIN PARALLELS AT SPAD 52+89 IN NO. 2 ENTRY, RIGHT RETURN. 320' OUTBY FACE. THE DIMENSIONS OF TH4E FALL ARE 40'N LONG, 17' WIDE, AND 12' HIGH.

March 5, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FAL HAS OCCURRED IN THE EAST MAIN PARALLELS AT SPAD 50 + 19 IN NO. 2 ENTRY. THE DIMENSIONS OF THE FALL AREA 18' LONG, 17' WIDE AND 10' HIGH. THE FALL IS IN THE RIGHT RETURN AND OUTBY TY HE LOADING POINT.

March 2, 1998 KY · Coal maintenance man, mechanic, repair/serviceman, boilermaker, fueler, tire tech, field service tech HANDLING OF MATERIALS
Lodestar Energy Inc · Caught in, under or between (Not Elsewhere Classified)

EMPLOYEE WAS HOLDING DOOR BUT DID NOT HAVE HIS HAND OUT OF THE WAY AND THE DOOR SLAMMED SHUT ON HIS LEFT RING FINGER.

February 21, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL OCCURRED IN THE EAST MAIN PARALLELS AT SPAD 42+54 IN NO. 2 ENTRY. THE FALL IS JUST OUTBY THE INTERSECTION. THE DIMENSIONS OF THE FALL AREA 25' LONG, 17' WIDE, AND 9' HIGH.

February 20, 1998 KY · Coal roof bolter, rock bolter, pinner, mobile roof support operator (mrs) HANDLING OF MATERIALS
Lodestar Energy Inc · Flash burns (welding)

EMPLOYEE WAS PUTTING A ROOF BOLT ON THE POT WHEN THE PIN BOARD SLID DOWN THE PIN AND MASHED HIS LEFT LITTLE FINGER.

February 15, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE EAST MAIN PARELLELS AT SPAD 42+69 IN NO. 8 ENTRY & CROSSCUT TO NO.9 ENTRY THE DIMENSIONS OF THE FALL ARE 40'L 17'WIDE AND 10' HIGH.

February 13, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURED IN THE EAST MAINS PARELLELS AT SPAD 42+54 IN NO 7 ENTRY. THE DIMENSIONS OF THE FALL ARE 17'L , 17' WIDE & 9' HIGH.

February 10, 1998 KY · Coal shuttle car operator, mantrip operator, ramcar operator, rail runner, buggy operator FALL OF ROOF OR BACK
Lodestar Energy Inc · Struck by falling object

EMPLOYEE WAS WALKING UP THE #4 ENTRY WHEN A PIECE OF ROCK FELL FROM BETWEEN PINS AND STRUCK HIM ON THE HEAD,CHEST AND LEGS.

January 31, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE EAST MAIN PARALLELS AT SPAD 24+90 IN #9 ENTRY. THE DIMENSIONS OF THE FALL ARE 40' LONG 17' WIDE 10 HIGH. THE FALL IS 2100 OUTBY THE UNIT IN THE LEFT RETURN.

January 29, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THEFIRST SOUTH PANEL AT SPAD 4 & 90 IN NO.7 ENTRY. THE DIMENSIONS OF THE FALL ARE 17' LONG, 18' WIDE, 10' HIGH.

January 29, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE FIRST SOUTH PANEL AT SPAD 4 & 90 IN NO.3 ENTRY AND THRU THE CROSSCUT TO NO.2 ENTRY. THE DIMENSION OF THE FALL ARE 80' LONG, 17' WIDE AND 8' HIGH.

January 29, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE FIRST SOURTH PANEL AT SPAD 4 & 20 IN NO.8 ENTRY. THE DIMENSIONS OF THE FALL ARE 18'LONG, 18' WIDE, 8' HIGH.

January 27, 1998 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE EAST MAIN PARALLELS AT SPAD 34+29 IN NO. 9 ENTRY. THIS IS A RETURN ENTRY. FALL IS 1500' OUTBY FACES.

January 25, 1998 KY · Coal roof bolter, rock bolter, pinner, mobile roof support operator (mrs) OTHER
Lodestar Energy Inc · Struck by... (Not Elsewhere Classified)

EE WAS PUTTING GLUE IN PIN HOLE, HE SNEEZED CAUSED THE GLUE TO SLIPPED OUT OF HIS HAND AND STRIKE HIM IN THE LEFT EYE.

1997 · 83 incidents

December 30, 1997 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE EAST MAIN PARALLELS AT SPAD 8 & 40 IN NO.1 ENTRY. THE DIMENSIONS OF THE FALL ARE 18'L,18'W AND 9'H. THE FALL IS 2600' OUTBY THE WORKING SECTION IN THE RETURN.

December 27, 1997 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURED INT HE MAIN EAST PARALLEL ENTRIES AT SPAD 28 + 50 BETWEEN #5 AND #6 ENTRIES. THE DIMENSIONS OF THE FALL ARE 40'L 17'W, AND 9' HIGH.

December 17, 1997 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE EAST MAIN PARALLELS AT SPAD 26+70 IN NO. 6 AND NO. 7 ENTRY INTERSECTIONS AND THE CONNECTING CROSSCUT. THE DIMENSION SOF THE FALL ARE 76'LX116'WX12'H.

December 14, 1997 KY · Coal roof bolter, rock bolter, pinner, mobile roof support operator (mrs) HANDLING OF MATERIALS
Lodestar Energy Inc · Over-exertion in lifting objects

EE WAS OPERATING ROOF BOLTER & TURNED TO PICK UP A ROOF BOLT & THREW HIP OUT OF PLACE.

November 28, 1997 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE MAIN EAST PARELLELS AT SPAD 9+80 IN NO4 ENTRY. THE DIMENSIONS OF THE FALL ARE 18'L, 18'W, 8' HIGH. RETURN ENTRY.

November 22, 1997 KY · Coal beltman, conveyor man, conveyor belt worker, mobile bridge carrierman, feeder operator, conveyor rider HANDTOOLS (NONPOWERED)
Lodestar Energy Inc · Struck by... (Not Elsewhere Classified)

EE WAS HELPING COMEALONG BELT TOGETHER AND BELT RIPPED AND COMEALONG CAME LOOSE. EITHER THE COMEALONG OR BELT BLOCKS STRUCK EE'S RIGHT RIB CAGE.

November 21, 1997 KY · Coal beltman, conveyor man, conveyor belt worker, mobile bridge carrierman, feeder operator, conveyor rider SLIP OR FALL OF PERSON
Lodestar Energy Inc · Fall to the walkway or working surface

EE WAS WALKING AND TRIPPED AND FELL, DISLOCATINGHIS MIDDLE FINGER.

November 20, 1997 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE FIRST NORTH PANEL AT SPAD 7+00 IN NO3 ENTRY. THE DIMENSIONS OF THE FALL ARE 22'L, 17'W, AND 14'HIGH. RETURN ENTRY.

November 15, 1997 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURED IN THE 1ST EAST PANEL ATSPAD 4 + 50 IN N07 ENTRY. THE DIMENSIONS OF THE FALL ARE 60'L, 17'W, AND 1O' HIGH.

November 15, 1997 KY · Coal roof bolter, rock bolter, pinner, mobile roof support operator (mrs) EXPLODING VESSELS UNDER PRESSURE
Lodestar Energy Inc · Struck against stationary object

HOSE BLEW ON ROOF BOLTER BLOWING OIL IN EE'S FACE. EE RAN AROUND ROOF BOLTER TO CHECK ON COWORKER WHEN HE RAN INTO A ROOF BOLT CUTTING HIS RIGHTFOREARM.]

November 10, 1997 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURED IN THE 1ST EAST PANEL AT SPAD 18 + 40 IN NO.6 ENTRY. THE DIMENSIONS OF THE FALL ARE 30' LONG, 17' WIDE AND 12' HIGH.

November 4, 1997 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURED IN THE 1ST EAST PANEL AT SPAD 9 + 30 IN NO.1 ENTRY, THE DIMENSIONS OF THE FALL ARE 18' LONG, 18' WIDE, 8' HIGH.

October 30, 1997 KY · Coal maintenance man, mechanic, repair/serviceman, boilermaker, fueler, tire tech, field service tech HANDTOOLS (NONPOWERED)
Lodestar Energy Inc · Over-exertion (Not Elsewhere Classified)

EMPLOYEE WAS PRYING A RUB RAIL ON MINER WHEN THE LARGE SCREW DRIVER SLIPPED CAUSING HIM TO TWIST HIS BACK.

October 29, 1997 KY · Coal roof bolter, rock bolter, pinner, mobile roof support operator (mrs) FALL OF ROOF OR BACK
Lodestar Energy Inc · Struck by falling object

EE WAS WALKING NEXT TO THE ROOF BOLTER WHEN A PIECE OF ROCK FELL STRIKING HIS HARD HAT AND CUTTING A PLACE ON HIS RIGHT CHEEK.

October 27, 1997 KY · Coal maintenance man, mechanic, repair/serviceman, boilermaker, fueler, tire tech, field service tech SLIP OR FALL OF PERSON
Lodestar Energy Inc · Over-exertion (Not Elsewhere Classified)

EE WAS GETTING OUT OF THE OPERATOR'S DECK OF SCOOP WHEN HIS RIGHT LEG SLIPPED CAUSING HIM TO HYPER-EXTEND.

October 25, 1997 KY · Coal laborer, bull gang, faceman, parts runner, roustabout, roof trimmer/scaler FALL OF ROOF OR BACK
Lodestar Energy Inc · Struck by falling object

EE PLACED HIS HAND ON TOP OF PINS BOARDS THAT WERE SITTING ON A ROOF BOLTER WHEN A PIECE OF ROCK FELL BETWEEN PINS & STRUCK HIS LEFT HAND.

October 23, 1997 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN EAST MAIN PARALLEL AT SPAD 7+70 IN NO. 9 ENTRY. THE DIMENSIONS OF THE FALL ARE: 22' LONG, 18' WIDE, 9' HIGH. THE FALL IS IN THE RIGHT RETURN, 1700' OUTBY THE UNIT.

October 22, 1997 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE EAST MAIN PARALLEL ENTRIES AT SPAD 7+70 IN NO. 1 ENTRY. THE DIMENSIONS OF THE FALL ARE 17' LONG, 18' WIDE AND 10' HIGH.

October 18, 1997 KY · Coal brattice man/worker HANDTOOLS (NONPOWERED)
Lodestar Energy Inc · Struck by... (Not Elsewhere Classified)

EMPLOYEE WAS USING A HAMMER TO DRIVE WEDGE BOARD BETWEEN ROOF AND CRIB WHEN HE STRUCK HIS LEFT THUMB WITH HAMMER.

October 11, 1997 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURED IN THE FIRST NORTH PANEL AT SPAD 5+60 IN NO. 5 ENTRY. THE DIMENSIONS OF THE FALL ARE 10'L, 17'W & 8'H.

October 10, 1997 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE FIRST EAST PANEL AT SPAD 2+70 IN NO. 6 ENTRY. THE DIMENSIONS OF THE FALL ARE 17'L, 18'W & 10'H.

October 5, 1997 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURED IN THE FIRST EAST PANEL AT SPAD 9 + 30 IN NO. 3 ENTRY. THE DIMENSIONS OF THE FALL ARE 16' LONG, 16' WIDE AND 9' HIGH.

October 4, 1997 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE FIRST EAST PANEL AT SPAD 9 & 30 IN NO.8 ENTRY. THE DIMENSIONS OF THE FALL ARE 17' LONG, 17' WIDE AND 9' HIGH.

September 26, 1997 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE FIRST EAST PANEL AT SPAD 6+ 90 IN NO. 5 ENTRY. THE DIMENSIONS OF THE FALL AREA 17' LONG, 18' WIDE AND 9' HIGH.

September 26, 1997 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE FIRST NORTH PANEL AT SPAD 4+90 IN NO. 3 ENTRY. THE DIMENSIONS OF THE FALL ARE 18' LONG, 19' WIDE AND 12' HIGH.

September 17, 1997 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURED IN THE EAST MAIN PARRALLELS AT SPAD 8+40 IN NO.3 ENTRY. THE DIMENSION OF THE FALL ARE 17' LONG 18' WIDE AND 9' HIGH. THE FALL IS 2300 OUTBY THE SECTION IN A RETURN ENTR Y.

September 17, 1997 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE FIRST EAST PANEL AT SPAD 3 90 IN NO. 9 ENTRY. THE DIMENSIONS OF THE FALL ARE 60' LONG,17' WIDE AND 9' HIGH.

September 11, 1997 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE FIRST NORTH PANEL AT SPAD 3+50 IN NO. 8 ENTRY. THE DIMENSIONS OF THE FALL ARE 17' LONG, 17' WIDE AND 8' HIGH. THIS IS A RETURN ENTRY.

September 10, 1997 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE FIRST NORTH PANEL IN NO. 2 ENTRY AT SPAD 4+20. THE DIMENSIONS OF THE FALL ARE 23' LONG, 17' WIDE AND 6 1/2' HIGH. THE FALL IS IN AN INTAKE ENTRY.

September 8, 1997 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE EAST MAIN PARREL ENTRIES AT SPAD 9+10 IN NO. 7 ENTRY. THE DIMENSIONS OF THE FALL ARE 20' LONG, 17' WIDE AND 9' HIGH.

September 8, 1997 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE EAST MAIN ENTRIES AT SPAD 6+8S IN NO. 2 ENTRY. THE DIMENSIONS OF THE FALL ARE 20' LONG, 17' WIDE AND 8' HIGH.

September 5, 1997 KY · Coal maintenance man, mechanic, repair/serviceman, boilermaker, fueler, tire tech, field service tech HANDLING OF MATERIALS
Lodestar Energy Inc · Over-exertion in lifting objects

EMPLOYEE WAS LIFTING H BEAM AND STRAINED LOWER BACK.

August 25, 1997 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

ROOF FALL HAS OCCURRED INTHE EAST MAIN PARALLELS AT SPAD 4 + 20 IN #7 ENTRY. THIS IS AN INTAKE ENTRY, APPROX 450' OUTBY THE WORKING SECTION. THE DIMENSIONS OF THE FALL ARE 25'L, 18'W, 9'H.

August 13, 1997 KY · Coal timberman STEPPING OR KNEELING ON OBJECT
Lodestar Energy Inc · Struck against stationary object

EMPLOYEE WAS HELPING CARRY A TIMBER WITH ANOTHER EMPLOYEE AND SLIPPED ON A PIECE OF ROCK ON THE MINE FLOOR PULLING A MUSCLE IN HIS LOWER BACK.

August 11, 1997 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE EAST MAIN PARALLEL ENTRIES AT SPAD 5+60 IN NO. 4 ENTRY, LAST OPEN CROSSCUT. THE DIMENSIONS OF THE FALL ARE 23'LX22'WX8'H.

August 11, 1997 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

ROOF FALL HAS OCCURRED IN THE SOUTH MAIN ENTRIES AT CROSSCUT 44 IN #5 ENTRY AT SPAD 34 + 90. THE DIMENSIONS OF FALL ARE 50'L, 18'W, 9'H. THIS IS A LIMITED INTAKE ENTRY. APPROX 8200' FROM THE W ORKING SECTION.

August 7, 1997 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE EAST MAIN ENTRIES INBY SPAD 37 & 30 IN NO.7 ENTRY. THE DIMENSIONS OF THE FALL ARE 15' LONG, 17' WIDE AND 6' HIGH. THUS IS A RETURN ENTRY. APPROX. 1300' OUTBY TH E WORKING SECTION.

August 4, 1997 KY · Coal FALL OF ROOF OR BACK
Lodestar Energy Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE EAST MAN ENTRIES OUTBY SPAD 37 & 30 IN NO. 7 ENTRY. THE DIMENSIONS OF THE FALL ARE 15'LX17'WX6'H. THE FALL IS IN A RETURN ENTRY. IT IS APPROX. 1200' OUTBY THE W ORKING SECTION.

July 23, 1997 KY · Coal maintenance man, mechanic, repair/serviceman, boilermaker, fueler, tire tech, field service tech FALL OF ROOF OR BACK
Lodestar Energy Inc · Fall down raise, shaft or manway

EE WAS BENDING OVER INSTALLING GOB SWITCH ON #3 HEADER WHEN A PIECE OF ROCK FELL BETWEEN PINS AND STRUCK HIM ON THE LEFT SIDE OF HIS HEAD.

July 20, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE EAST MAIN ENTRIES AT SPAD 37+30 IN N07 ENTRY. THE DIMENSIONS OF THE FALL ARE 25'LONG 14'WIDE AND 8' HIGH. THIS FALL IS IN A LIMITED INTAKE/RETURN OVERCAST INTER SECTION APPROX 700' OUTBY THE WORKING SECTION

July 9, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE SOUTH MAINS AT SPAD 15+70 IN NO. 3 ENTRY. THE DIMENSIONS OF THE FALL AREA 50' LONG, 17' WIDE, AND 9' HIGH. THIS IS A LIMITED INTAKE ENTRY. THE FALL IS 2800' FRO M THE UNIT.

July 1, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE SOUTH MAIN PARALLELS AT SPAD 13+65 IN NO. 2 ENTRY. THE DIMENSIONS OF THE FALL AREA 17' LONG, 18' WIDE, AND 10' HIGH. THIS IS A RETURN ENTRY 4600' OUTBY THE UNIT .

June 24, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN TEH 2ND SOUTH MAIN ENTRIES AT SPAD 7+70 IN NO. 2 ENTRY. THE DIMENSIONS OF THE FALL ARE 18' LONG, 18' WIDE, 10' HIGH. INTAKE ENTRY. 1400' OTUBY UNIT.

June 24, 1997 KY · Coal shuttle car operator, mantrip operator, ramcar operator, rail runner, buggy operator HANDLING OF MATERIALS
Costain Coal Inc · Over-exertion (Not Elsewhere Classified)

EE WAS PULLING UP PINNER CABLE AND STRAINED BACK AND PULLED MUSCLE IN GROIN.

June 10, 1997 KY · Coal roof bolter, rock bolter, pinner, mobile roof support operator (mrs) MACHINERY
Costain Coal Inc · Struck by falling object

EE WAS INSTALLING ROOF BOLT, WHEN THE PIN BOARD AND PLATE FELL AND STRUCK HIS RIGHT RING FINGER.

June 2, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

ROOF FALL HAS OCCURRED IN THE 2ND NORTHEAST SUBMAINS AT SPAD 21+00 IN #3 ENTRY. THE DIMENSIONS OF THE FALL ARE 20'L, 17'W, 9'H.THE FALL IS 1800'OUTBY THE UNIT IN A RETURN ENTRY.

May 28, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE 2ND NORTHEAST SUBMAINS AT SPAD 15+75 IN NO. 7 ENTRYL. THE DIMSNSIONS OF THE FALL AREA 45' LONG, 17' WIDE, AND 12' HIGH. THE FALL IN 200' OUTBY THE UNTI IN A RET URN ENTRY.

May 27, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE SOUTH MAIN PARALLELS AT SPAD 29+40 IN NO. 3 ENTRY. THE DIMENSIONS OF THE FALL AREA 20' LONG, 18' WIDE, 8' HEIGHT. THE FALL IS 6000' OUTBY THE UNIT IN A LIMITED INTAKE ENTRY.

May 27, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE SOUTH MAIN PARALLEL ENTRIES AT SPAD 31+15 IN NO. 4 ENTRY. THE DIMENSIONS OF THE FALL AREA 20' LONG, 18' WIDE AND 10' GHIH. THE FALL IS 6200' OUTBY THE UNIT IN A LIMTED INTAKE ENTRY.

May 13, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE 2ND NE SUBMAINS BETWEEN SPADS 18 + 90 & 19 + 95 IN #7 ENTRY. THEDIMENSIONS OF THE FALL ARE 20'L, 17'W, & 8' H. THE FALL IS 2000 OUTBY THE SECTION IN RETURN.

May 7, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURED IN THE SECOND N.E. SUBMAINS AT SPAD 6+30 IN CROSSCUT BETWEEN NO.6 AND NO.7 ENTRIES. THE DIMENSIONS OF THE FALL ARE 25' LONG,17' WIDE AND 10' HIGH. THE FALL IS 2000 OUTB Y THE UNIT INTAKE.

May 7, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURED IN THE SECOND SUBMAINS AT SPAD 5+25 IN NO.7 ENTRY. THE DIMENSIONS OF THE FALL ARE 25' LONG. 20' WIDE AND 10' HIGH. 2000' OUTBY UNIT. RETURN.

April 27, 1997 KY · Coal roof bolter, rock bolter, pinner, mobile roof support operator (mrs) MACHINERY
Costain Coal Inc · Struck by falling object

EE WAS INSTALLING A ROOF BOLT WHEN A PIECE OF ROCK FELL BETWEEN THE ATRS AND ROOF BOLTER, STRIKING HIM ON THE HEAD AND NECK.

April 24, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE SOUTH MAIN PARALLELS AT SPAD 18+90 IN NO. 3 ENTRY. THE DIMENSIONS OF THE FALL ARE 30' LONG, 17-1/2' WIDE AND 8' HIGH.

April 15, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURED IN THE 2ND N.E. SUBMAIN IN THE NO.4 INTERSECTION OF SPAD 5 & 25. THE DIMENSIONS OF THE FALL ARE 30'LX17'WX12'H. THE FALL IS 1900' OUTBY THE WORKING SECTION FACES.

April 14, 1997 KY · Coal maintenance man, mechanic, repair/serviceman, boilermaker, fueler, tire tech, field service tech STEPPING OR KNEELING ON OBJECT
Costain Coal Inc · Struck against stationary object

EE WAS WALKING DOWN THE BELTLINE, STEPPED ON A ROCK CAUSING HIM TO TWIST HIS RIGHT ANKLE.

April 8, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE SOUTH MAIN PARSULS AT SPAD 25+20 IN NO. 4 ENTRY. THE DIMENSIONS OF THE FALL AREA 140'LX17'WX10'H. 4200' OUTBY SECTION NEUTRAL ENTRY.

April 6, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

ROOF FALL HAS OCCURRED IN SOUTH MAIN PARALLELS AT SPAD 4+58 IN #3 ENTRY. DIMENSIONS OF FALL ARE 24'L, 17'W, 5'H. THIS 5200' OUTBY THE SECTION. FALL WILL BE CLEANED UP. NEUTRAL AIR ENTRY.

April 4, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE 2ND SOUTH MAIN ENTRIES AT SPAD 0+70 IN NO. 7 ENTRY. THE DINENSIONS OF THE FALL AREA 20' LONG, 17' WIDE, AND 10' HIGH. THIS WAS A RETURN ENTRY OUTBY THE SECTION LOADING POINT.

March 28, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE 2ND NORTHWEST SUBMAINS AT SPAD 14 & 70 IN NO.8 ENTRY. THE DIMENSIONS OF THE FALL ARE 25'LX17'WX10'H. THE FALL IS OUTBY THE WORKING SECTION.

March 28, 1997 KY · Coal bull gang foreman, labor foreman, leadman, section foreman, shift boss FALL OF ROOF OR BACK
Costain Coal Inc · Struck by falling object

WHILE STANDING IN NO. 6 ENTRY A PIECE OF ROCK FELL FROM BETWEEN ROOF BOLTS AND STRUCK EMPLOYEE ON HEAD.

March 27, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE 2ND NORTHEAST SUBMAINS AT SPAD 23 10 IN NO.3 ENTRY THE DIMENSON OF THE FALL ARE 70' L X 17' W X 10' H. THE FALL IS OUTBY THE SECTION.

March 23, 1997 KY · Coal apprentice, trainee HANDLING OF MATERIALS
Costain Coal Inc · Over-exertion in lifting objects

WHILE BUILDING A CRIB EMP PULLED MUSCLE IN HIS CHEST LIFTING A CRIB BLOCK.

March 21, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE SOUTH MAIN PARALLELS AT SPAD 15+75 IN NO. 8 ENTRY. THE DIMENSIONS OF THE FALL ARE 20'LONG, 17'WIDE AND 8'HIGH. FALL IS 3400' OUTBY SECTION IN LIMITED INTAKE.

March 17, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN EAST MAIN ENTRIES AT SPAD 46+30 IN NO. 1 ENTRY. THE DIMENSIONS OF THE FALL ARE: 20' LONG, 18' WIDE, AND 6' HIGH. 8800' OUTBY THE SECTION.

March 15, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE 2ND N.E. SUBMAINS AT SPAD 6+30 IN NO. 2 & 3. THE DIMENSIONS OF THE FALL ARE: 80' LONG, 17' WIDE AND 12' HIGH. 1100' OUTBY SECTION.

March 5, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE 2ND NE SUBMAINS AT SPAD 8+40 IN NO. 8 ENTRY. THE DIMENSIONS OF THE FALL AREA 18' LONG, 18' WIDE, 9' HIGH. THIS IS A RETURN ENTRY. THE FALL IS INBY THE DUMPING P OINT, 240' OUTBY THE LAST OPEN CROSSCUT.

February 27, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE 2ND NORTHEAST SUBMAINS IN THE NO. 7 ENTRY AT SPAD 7+35. THE DIMENSIONS OF THE FALL ARE 28' LONG, 20' WIDE AND 12' HIGH. INBY DUMPING POINT. NEUTRAL ENTRY. WILL BE CLEANED UP.

February 23, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN SECOND NORTHEAST SUBMAINS AT SPAD 6 & 30 BETWEEN NO.4 AND NO.5 ENTRIES. THE FALL IS 25' L X 10' TO 17' WIDE AND 9 HIGH. FALL WILL BE CLEANED UP.

February 23, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED INT HE SOUTH MAIN PARALLELS IN NO. 3 ENTRY OUTBY SPAD 14&70. THE DIMENSIONS OF THE FALL AREA 20'L 1`6' WIDE 9' HIGH. FALL WILL BE CLEANED UP.

February 11, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE SOUTH MAIN ENTRIES AT SPAD 23+70 IN NO. 3 ENTRY. THE DIMENSIONS OF THE FALL ARE 18' WIDE, 18' LONG, 10' HIGH. RETURN, INTERSECTIO, WILL NOT BE CLEANED UP. 4000' OUTBY SECTION.

February 10, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE SOUTH MAIN PARALLEL ENTRIES AT SPAD 6+30 IN NO. 7 ENTRY. THE DIMENSIONS OF THE FALL ARE 22 X 17 X 10'. FALL IS OUTBY SECTION.

February 8, 1997 KY · Coal greaser, grease man, oiler, lube man, dragline oiler SLIP OR FALL OF PERSON
Costain Coal Inc · Fall onto or against objects

EMP WAS ROCKDUSTING AND WAS BACKING UP WITH THE ROCKDUST HOSE AND TRIPPED OVER A TIMBER AND TWISTED HIS RIGHT KNEE.

January 28, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE SOUTH MAIN PARALLEL BETWEEN NO. 1 AND NO.8 ENTRIES AT SPAD 3 & 15. THIS DIMENSIONS ARE 30' LONG, 17' WIDE AND 8' HIGH. THIS IS A RETURN. ABOUT 3100' OUTBY UNIT.

January 21, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE S. MAIN ENTRIES AT SPAD 28+50 IN NO. 2 ENTRY. THE DIMENSIONS OF THE FALL ARE 20' LONG, 20' WIDE AND 20' HIGH. 6000' OUTBY UNIT.

January 13, 1997 KY · Coal laborer, bull gang, parts runner, roustabout, roof trimmer/scaler HANDLING OF MATERIALS
Costain Coal Inc · Struck by falling object

EE WAS HELPING PUT UP ARCHES, WHEN THE ARCH STARTED FALLING AND STRUCK HIM IN THE BACK OF THE HEAD AND NECK.

January 8, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

ROOF FALL HAS OCCURRED IN THE SOUTH MAIN PARALLELS AT SPAD 25 + 20 IN #8 ENTRY. THE DIMENSIONS OF THE FALL ARE 18'L, 20'W, 8'H.

January 7, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

ROOF FALL HAS OCCURRED IN THE SOUTH MAIN ENTRIES AT SPAD 35+70 IN #9 ENTRY. THE DIMENSIONS OF THE FALL ARE 18'L, 18'W, 12'H. 3600' OUTBY UNIT.

January 7, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

ROOF FALL OCCURRED IN THE SOUTH MAIN PARALLEL ENTRIES IN #3 ENTRY AT SPAD 4+20. DIMENSIONS OF FALL ARE 20'L, 20'W, 10'H. 1900' OUTBY UNIT. WILL BE CLEANED UP.

January 6, 1997 KY · Coal roof bolter, rock bolter, pinner, mobile roof support operator (mrs) MACHINERY
Costain Coal Inc · Caught in, under or between a moving and a stationary object

RIB ROLLED OFF PINNER CANOPY AND CAUGHT EMPLOYEE'S LEFT LEG BETWEEN RIB AND PINNER.

January 5, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE NORTH EAST SUBMAIN AT SPAD 5+90 IN NO. 8 ENTRY. THE DIMENSIONS OF THE FALL ARE 20' X 20' X 10'. THE FALL IS APPROXIMATELY 2500' OUTBY THE WORKING FACE.

January 5, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL OCCURRED IN THE SOUTH MAIN PARALLEL ENTRIES AT SPAD 24+20 IN NO. 6 ENTRY INTERSECTION. THE DIMENSIONS OF THE FALL ARE 60' LONG 18' WIDE AND 8' HIGH. THE FALL IS INBY THE LOADING PO INT.

January 2, 1997 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE SOUTH MAIN ENTERIES AT SPAD 28 & 50 IN NO.8 ENTRY INTERSECTION, RETURN, WILL NOT CLEAN UP, 4700' OUTBY UNIT.

1996 · 34 incidents

December 19, 1996 KY · Coal roof bolter, rock bolter, pinner, mobile roof support operator (mrs) MACHINERY
Costain Coal Inc · Struck by flying object

EMP WAS ATTEMPTING TO DISLODGE A 48" PINNER STEEL THAT HAD BECOME LODGED IN CHUCK. EMP PLACED THE END OF PINNER STEEL AGAINST RIB IN AN 8" WEDGE. WHEN EMP HIT THE ROTATION LEVER IT CAUSED THE PINNER STEEL TO SPIN AROUND AND STRIKE LFT HAND.

December 17, 1996 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE EAST NORTHEAST SUBMAINS OUTBY SPAD 0+00 IN NO. 4 ENTRY. THE DIMENSIONS OF THE FALL ARE 40' LONG, 18' WIDE AND 8' HIGH. THE FALL IS 2800' OUTBY THE WORKING SECTI ON FACES.

December 17, 1996 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAD OCCURRED AT THE 1ST N.E. SUBMAINS AT SPAD 3+10 IN NO. 9 ENTRY, RETURN, WILL NOT BE CLEANED UP, 1260' OUTBY FACES.

December 9, 1996 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

ROOF FALL HAS OCCURRED IN THE SOUTH MAIN NO. 8 ENTRY AT CROSSCUT 19, SPAD 14 + 90 INTERSECTION, RETURN WILL BE CLEANED UP, 4200 OUTBY UNIT.

December 5, 1996 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE SOUTH MAIN PARALLELS IN NO. 3 ENTRY AT SPAD 3+15' THE DIMENSIONS OF THE FALL ARE 18'L, 20'W, & 8'J\H. THE FALL IS 700' OUTBY THE UNIT.

December 4, 1996 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE EAST MAIN ENTRIES AT SPAD 22+10 IN NO. 3 ENTRY. THE DIMENSIONS OF THE FALL ARE 22'L, 18'W, & 8'H. THE FALL IS 9200' OUTBY THE UNIT.

December 3, 1996 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE SOUTH MAIN ENTRIES AT SPAD 7+70 IN NO. 7 ENTRY. THE DIMENSIONS OF THE FALL ARE 40'L, 18'W, & 8'H. THE FALL IS 4800' OUTBY THE UNIT.

December 3, 1996 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE SOUATH MAIN ENTRIES AT SPAD 22+10 IN NO. 8 ENTRY. THE DIMENSIONS OF THE FALL ARE 18'L, 18'W, & 10'H. THE FALL IS 3400' OUTBY THE UNIT.

December 1, 1996 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A CONTINUATION OF A PREVIOUS FALL HAS OCCURRED IN NO.7 ENTRY OF THE 1ST NORTHEAST SUBMAINS AT SPAD 1&70 THE DIMENSIONS OF THE FALL AREA 60' LONG, 18' WIDE, 10' HIGH.

November 29, 1996 KY · Coal brakeman, roperider, car runner, spotterman, snapper, trip rider, car rider, flagman SLIP OR FALL OF PERSON
Costain Coal Inc · Fall from ladders

EE WAS PULLING A CURTAIN DOWN WHEN THE LADDER FELL OVER CAUSING EE TO FALL ON HIS LEFT FOREARM.

November 29, 1996 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN NO.L8 ENTRY OF THE 1ST NORTHEAST SUBMAINS AT SPAD 1 & 70. THE DIMENSIONS OF THE FALL AREA 100' LX18'WX10'H. THE FALL WAS 800' OUTBY THE UNIT.

November 25, 1996 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURED IN THE SOUTH MAIN PARALLEL ENTRIES AT SPAD 1+05 IN #7 ENTRY. THE DEMENSIONS OF THE FALL ARE 20'L, 20'W, 10'H. THE FALL IS OUTBY THE LOADING POINT.

November 21, 1996 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE SOUTH MAIN PARALLEL ENTRIES AT SPAD 4 + 20 IN #2 ENTRY. THE DIMENSIONS OF THE FALL ARE 20'L, 20'W, & 10'H. THE FALL IS INBY THE LOADING POINT.

November 18, 1996 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

EAST MAIN ENTRIES IN NO 4 ENTRY AT CROSSCUT NO1 100 FT INBY RETURN PORTAL, EXTENSION OF PREVIOUS FALL, OUTBY BROW.

November 2, 1996 KY · Coal rock duster SLIP OR FALL OF PERSON
Costain Coal Inc · Fall onto or against objects

EMP WAS LOADING ROCKDUST BAGS. LOST HER FOOTING,FELL ON ROOF BOLT AND CONCRETE BLOCKS AND SPRAINED LOWER BACK.

October 24, 1996 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS 0CCURED IN THE 1ST NORTHWEST PANEL AT SPAD 6 + 40 IN N04 ENTRY INTERSECTION RETURN WILL NOT BE CLEANED UP. 2400' FROM UNIT DIMENSIONS OF THE FALL 60'L, 18' W, 8'WIDE

October 23, 1996 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURED IN THE SO MAIN ENTRIES AT SPAD 25 + 30 IN NO 2 ENTRY. THE DIMENSIONS OFTHE FALL ARE 30' LONG, 18' WIDE, AND 10' HIGH FALL IS 2000' OUTBY UNIT

October 23, 1996 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE FIRST NORTHWEST PANEL AT SPAD 12+00 IN NO. 5 AND NO. 6 ENTRY INTERSECTIONS. THE DIMENSION OF THE FALL ARE 100'LONG, 18' WIDE AND 8' HIGH.

October 19, 1996 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURREDIN THIS NORTHWEST PANEL IN NO. 3 ENTRY OF ROOMS. THE DIMENSION OF THE FALL AREA 18'LX18'WX10'H. THIS FALL WAS INBY THE LOADING POINT.

October 18, 1996 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURED IN THE NORTHWEST PANEL AT SPAD 7+20 IN NO. 1 AND NO. 2 ENTRIES. THE DIMENSIONS OF THE FALL ARE 300'LX18'WX12'H. THIS FALL IS APPROX 900' OUTBY THE FACES.

October 15, 1996 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

ROOF FALL 1ST SOUTHWEST MAIN 6 ENTRY LOCATED 18 & 10. DIMENSIONS OF THE FALL ARE 30 FT LONG, 20 ' WIDE, AND 15' FT HIGH APPROX. 6600 FT OUTBY UNTI.

October 8, 1996 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE WAST MAIN ENTRIES AT SPAD 53+30 IN NO. 3 ENTRY. THE DINENSIONS OF THE FALL ARE 25' LONG, 20' WIDE, 8' HIGH. APPROX. 6000' OUTBY UNIT.

October 7, 1996 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FAL HAS OCCURRED IN THE EAST MAIN ENTRIES AT SPAD 1+00 IN NO. 4 ENTRY. THE DIMENSIONS OF THE FALL AREA: 14' LONG, 18' WIDE, 8' HIGH. APPROX. 13,000' OUTBY UNIT.

October 1, 1996 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE SOUTH MAIN ENTRIES AT SPAD 30+10 IN NO. 9 ENTRY 4500' OUTBY THE UNIT FACES. THE DIMENSIONS OF THE FALL ARE 20'LX20'WX10'H.

September 30, 1996 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRE DIN THE SOUTH MAIN ENTRIES AT SPAD 33+30 IN NO. 4 ENTRY 4300' OUTBY THE UNIT FACES. THE DIMENSION OF THE FALL ARE 24'LX118'WX6'H.

September 29, 1996 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE NORTHWEST PANEL AT SPAD 11+30 BETWEEN NO. 6 AND NO. 7 ENTRIES. THE FALL IS 300'OUTBY THE FACES. THE DIMENSIONS OF THE FALL AREA 40'LX17'WX9'H.

September 29, 1996 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE NORTHWEST PANEL AT SPAD 6+00 IN NO. 7 ENTRY, 800' OUTBY THE UNIT FACES. THE DIMENSIONS OF THE FALL ARE 20'LX18'WX10'H.

September 29, 1996 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE NORTHWEST PANEL AT SPAD 8+50 IN NO. 7 ENTYR, 600' OUTBY THE UNIT FACES. THE DIMENSIONS OF THE FALL AREA 28'LX18'WX10'H.

September 23, 1996 KY · Coal roof bolter, rock bolter, pinner, mobile roof support operator (mrs) HANDLING OF MATERIALS
Costain Coal Inc · Over-exertion (Not Elsewhere Classified)

EMP WAS PUTTING AN EIGHT FOOT PIN IN THE PIN HOLE AND AS HE WAS STRAIGHTENING THE ROOF BOLT OUT HE PULLED A TENDON IN LEFT ELBOW.

September 22, 1996 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE NORTH WEST PANEL ENTRIES AT SPAD 13 & 40 IN NO.4 ENTRY INTERSECTION. THE OIMENSIONS OF THE FALL ARE 20' LONG, 20' WIDE, 10' HIGH.

September 22, 1996 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL OCCURRD IN THE NORTH WEST PANEL ENTRIES. AT SPAD 14-10 IN NO. 3 ENTRY AND X-CUT BETWEEN NO. 3 AND NO. 2 ENTRY.

September 18, 1996 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE SOUTH MAIN ENTRIES AT SPAD 21 & 30 IN NO.9 ENTRY. THE DIMENSION OF THE FALL IS 20'WIDE, 20' LONG AND 8' HIGH.

September 18, 1996 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE SOUTH MAIN ENTRIES AT SPAD 29 & 30, IN NO.4 ENTRY. THE DIMENSIONS OF THE FALL ARE 80' LONG, 18' WIDE AND 8' HIGH.

September 18, 1996 KY · Coal FALL OF ROOF OR BACK
Costain Coal Inc · Accident type, without injuries

A ROOF FALL HAS OCCURRED IN THE NORTHWEST PANEL AT SPAD 5 & 40 IN NO.7 ENTRY. THE DIMENSIONS OF THE FALL ARE 20'L X 20'W X 10' H.