Hauler backed over the outslope. The hauler traveled approximately 150 feet down the spoil pile. The operator was ejected from the cab of the hauler. Operator was a contract worker.
Cumberland River Coal LLC: 2 recorded fatalities operator
Watch this operator
Email me when a new MSHA incident is filed at any Cumberland River Coal LLC mine.
ⓘ
This rate is recorded citations divided by MSHA inspection hours, per 100 hours. It reflects inspection effort, not mine size or production.ⓘ
Differences between proposed and paid penalties reflect both settlements and conference reductions and amounts still owed. Outstanding is the balance currently owed.ⓘ
Shares are computed over citations that carry the MSHA gravity and negligence coding; a small share of records are uncoded.ⓘ
This rate is reportable injury cases per 100 full-time-equivalent workers per year, computed as 200,000 times cases divided by MSHA operator-reported employee-hours. Cases are injuries MSHA graded degree 01 through 07; accident-only events that hurt no one are excluded, and so are contractor injuries, whose hours do not attach to a single mine. Rates begin in 2000, when quarterly employment reporting starts, and are withheld below 20,000 hours in a year.| Year | total case rate | days-away | fatal |
|---|---|---|---|
| 2015 * | 0.00 | 0.00 | 0.000 |
| 2014 | 2.86 | 1.72 | 0.000 |
| 2013 | 3.37 | 2.36 | 0.000 |
| 2012 | 2.23 | 1.67 | 0.000 |
| 2011 | 1.05 | 0.63 | 0.000 |
| 2010 | 2.44 | 1.36 | 0.000 |
| 2009 | 3.32 | 1.81 | 0.000 |
| 2008 | 2.02 | 1.35 | 0.000 |
ⓘ
A sample is a point in time compliance measurement, not an individual exposure history. These figures describe MSHA sampling records and do not establish causation or personal dose.Respirable coal dust
ⓘ
Respirable coal dust and silica figures cover coal facilities. Dust compliance is measured against the current 1.5 mg/m3 standard; samples predating the 2014 standard are included, so compliance rates are a coarse historical signal.
Last sampled: 2014-07-23, 12 years ago
ⓘ
Respirable coal dust and silica figures cover coal facilities. Dust compliance is measured against the current 1.5 mg/m3 standard; samples predating the 2014 standard are included, so compliance rates are a coarse historical signal.- CONTINUOUS MINER OPERATOR1,692
- SCOOP CAR OPERATOR268
- ROOF BOLTER (TWIN HEAD) (RETURN SIDE)193
Silica (quartz)
Last sampled: 2014-04-15, 12 years ago- CONTINUOUS MINER OPERATOR163
- BULLDOZER OPERATOR7
- HIGHLIFT OPERATOR/FRONT END LOADER7
Noise
ⓘ
The share counts noise samples whose measured dose exceeded the 90 dBA permissible exposure limit. It describes the sampled workplace, not what reached the miner's ear: hearing conservation programs and the hearing protection worn during the shift are recorded separately and are not reflected here.
Last sampled: 2014-03-13, 12 years ago
ⓘ
The share counts noise samples whose measured dose exceeded the 90 dBA permissible exposure limit. It describes the sampled workplace, not what reached the miner's ear: hearing conservation programs and the hearing protection worn during the shift are recorded separately and are not reflected here.- CONTINUOUS MINER OPERATOR85
- SCOOP CAR OPERATOR84
- ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)63
ⓘ
Contesting a citation before the Federal Mine Safety and Health Review Commission is a lawful right. These figures state the public outcomes of that process, from MSHA's Contested Violations file.- Settled 302 · 100%
ⓘ
Counts a Significant & Substantial citation as surviving when a settlement or judge's decision kept the designation, or the contest was dismissed or defaulted so the citation stands as issued. Vacated and withdrawn citations, and settlements that removed the designation, count against.ⓘ
A reduction or dismissal at the Commission is a lawful outcome of contesting a proposed penalty. Figures are the proposed amount and the amount upheld in the docket's decision.| Docket | Decision | Judge | Year | Proposed / upheld |
|---|---|---|---|---|
| KENT 2010-1072 | Settlement | Barbour | 2012 | $133K → $86K |
| VA 2013-303 | Settlement | Bulluck | 2014 | $64K → $45K |
| VA 2015-0067 | Settlement | Lesnick | 2015 | $62K → $31K |
| KENT 2009-237 | Settlement | McCarthy | 2012 | $60K → $60K |
| KENT 2010-1192 | Settlement | Barbour | 2011 | $54K → $11K |
| VA 2013-229 | Settlement | Bulluck | 2014 | $43K → $31K |
Top causes
- POWERED HAULAGE 1 fatality · 51 non-fatal
- ELECTRICAL 1 fatality
- FALL OF ROOF OR BACK 101 non-fatal
- HANDLING OF MATERIALS 90 non-fatal
- SLIP OR FALL OF PERSON 72 non-fatal
- HANDTOOLS (NONPOWERED) 45 non-fatal
Incident timeline
Mines on record
- Trace Fork 1 Mine KY
- PINE BRANCH 1 VA
- BAND MILL MINE VA
- Band Mill 2 KY
- PARDEE PLANT/LOADOUT VA
- S-17 Cumberland KY
- Blue Ridge No 1 KY
- Mine No 9 KY
- Blackwood KY
- Dogwood #3 VA
- Pardee Surface VA
- Ridgeline Mine KY
- Oven Fork Surface Facilities KY
- Wolverine Loadout (T-4) KY
- Tunnel Mine KY
- Ovenfork Mine KY
- P-1 Flint Ridge KY
Fatalities under this operator
2 recordedHE WAS ASSISTING A CERTIFIED ELECTRICIAN IN INSTALLING A 7200 VOLT PLUG (CATHEAD) WHEN HE APPARENTLY CAME IN CONTACT WITH AN ENERGIZED RECEPTACLE ON THE POWER DISTRIBUTION BOX (VCB). THIS RESULTED IN A FATAL.
Where Cumberland River Coal LLC stands on silica, penalties, and injury rate
MSHA's standard limits respirable silica to 50 micrograms per cubic metre, but MSHA publishes dust and quartz as separate files and never the silica figure itself. We derive it per sample, score it against the limit, and set the operator's injury rate against a benchmark built from the full MSHA operator record. With the 26-year penalty trail, contest posture, and fatality history. Delivered as a PDF with the underlying data as CSV.