TWO GROUND FAULTS OCCURRED ON TWO DIFFERENT PHASES OF THE UNDERGOUND POWER SYSTEM.THE FAN HAD A GROUND FAULT AND THE FLYGHT PUMP HAD A GROUND FAULT.THE PUMP GROUND FAULT WASTIEDTO THE UNDERGRO UND SYSTEM AND THE FAN WAS TIED TO THE SURFACE GROUND SYSTEM WITH THE HOIST.THE VICTIM BECAME THE BRIDGE BETWEEN THE TWO SYSTEMS.
Primrose Coal Company operator
Controlled by
David S Himmelberger et al
MSHA operator ID: P21776
Top causes
- ELECTRICAL 1 fatality
- FALL OF ROOF OR BACK 1 non-fatal
Incident timeline
1995
1 (1f)
1994
1
Mines on record
Fatalities under this operator
1 recorded
March 30, 1995
PA · Coal
laborer, bull gang, parts runner, roustabout, roof trimmer/scaler
Fatality · ELECTRICAL
Primrose Coal Company · Contact with electrical current
Watch this operator