ROOF FALL #3 ENTRY 5 BLOCKS OUTB FACE " NO PERSONS INVOLVED" NO EQUIPMENT INVOVED SECTION WAS IDEL FOR 8 DAYS. HOT WEATHER SWEAING. FALL 16'X20'X6'. CROSS CUT 4 WAY.
#1 Coal
MSHA record for #1 (mine ID 4606548). Fatalities, non-fatal incidents grouped by year, current operator and controller, and mine context.
Watch this mine
Email me when a new MSHA incident is filed at #1.
- Fatalities
- 0
- Total incidents
- 42
- Years on record
- 1983–1995
- Latest incident
- Jul 1995
ⓘ
This rate is recorded citations divided by MSHA inspection hours, per 100 hours. It reflects inspection effort, not mine size or production.ⓘ
Citations per million reported employee-hours. Rates begin in 2000, when MSHA's quarterly employment data starts; earlier incidents are counted but cannot be rate-adjusted. Quarters under 100,000 reported hours are greyed: too few hours for a stable rate.| Quarter | Hours worked | Citations | S&S | Per 1M hrs |
|---|---|---|---|---|
| 2000 Q2 | 0 | 0 | 0 | |
| 2000 Q1 | 0 | 0 | 0 |
Reportable incidents
42 on file1995 · 6 incidents
GREASING MINE FAN WHEN RIGHT FOOT WAS CAUGHT ON BOARD WALK TWISTING RIGHT FOOT
ROOF FALL #1 BELT HEADING 4 WAY INTERSECTION. AREA MINED 1983. FALL SIZE 6' X 14' 20'. HOT WEATHER CAUSING SWEATING, 1 NO. PERSON INVOLVED "NO EQUIPMENT INVOLVED".
BROKE 4TH FINGER RIGHT HAND, FEEDER ON #5 BELTLINE, WHEN CLOSING GUARD DOOR OVER FEEDER CHAIN CAUGHT FINGER UNDER GUARD. NOTE - FEEDER WAS NOT RUNNING.
FALL IN #1 ENTRY 3 BLOCKS FROM PITT MOUTH. SIZE 15' LONG, 15' WIDE, 6' HIGH. NO PERSON INVOLVED. NO EQUIPMENT INVOLVED. AREA MINED 1982. ROOF DRYING OUT.
ROOF FALL 5 BLOCKS FROM PITT MOUNTH, AREA MINED 12 YEARS AGO. (NO PERSON IN INVOLVED) (NO EQUIPMENT INVOLVED) FALL SIZE 20'X15'X6' RISEN BOLTS 6' (AIR SLACKED) CAUSING FALL TO OCCURE.
1994 · 6 incidents
ROOF FALL THREE BLOCKS FROM PITT MOUTH. ROOF DRYIED OUT FALL IN 4-WAY INTERSECTION FALL SIZE 20 X 15' X 6' NO PERSONS INVOLVED. NO EQUIPMENT INVLOVED.
ROOF FALL 3 BLOCKS FROM PITT MOUTH, SIZE 20' X 14' X 6'. NO PERSON INVOLVED, NO EQUIPMENT INVOLVED. HOT WEATHER MOISTURE MAKE ROOF SWELL. COLD WEATHER DRYS OUT THE ROOF CAUSING ROOF TO FALL.
ROCK FELL ON ROOF BOLTERS LEFT ARM WHEN BOLTING PLACE. NOT INJURED SERIOUS "BRUISED". PUTTING IN LAST BOLT IN WORKING FACE. LOOSE ROCK FELL AROUND 2 ROOF BOLTS STRIKING HIM ON LEFT ARM.
FALL #1 BELT LINE.NO PERSONS,NO EQUIPMENT INVOLVED.HOT WEATHER CAUSING MOISTURE TO BUILD UP.
FALL ON #1 BELT LINE 5 BLOCKS FROM PIT MOUTH. FALL 20' X 15' X 4'. NO PERSONS, NO EQUIPMENT INVOLVED. HOT WEATHER, SWEATING.
LOW BACK AS A RESULT OF PROLONGED HEAVY LIFTING. PER WORKERS COMP - 8%. PERMANENT PARTIAL DISABILITY (RECEIVED PAYMENT IN JUNE 1994/ WE RECIEVED PAYMENT NOTICE 7-18-94)
1993 · 6 incidents
FALL 6 BLOCKS FROM PIT MOUTH COOL AIR DRYING OUT ROOF. FALL WAS ON INTAKE AIR WAY. NO EQUIPMETN OR PERSONS INVOLVED. FALL SIZE 20'X10'X4'.
REABILITATING TRAVELWAY ROOF SUPPORT. ROCK SLIDE APPROX. 12" DOWN ROOF BOLT CATCHING LEFT FINGER BETWEEN ROCK & ROOF BOLT PLATE.
HOT WEATHER CAUSING MOISTURE TO BUILD UP LOOSEN ROCK
HELPER WENT TO GET ROOF BOLTS AT SUPPLY HOLE. 2 PIECES OF ROCK FELL FROM ROOF: #1 15"X6"X2" (APPROX. 7 LBS). #2 12"X6"X2" (APPROX. 5 LBS). ARM BROZ
HOT WEATHER SWEATING IN 9 OF MINE ROOF 25' LONG, 15' WIDE, 7' HIGH. NO PERSON INVOLVED. NO EQUIPMENT INVOLVED.
NO ACCIDENT- DEGENERATION OF SPINE-WORKERS COMP RULED COMPENSABLE-BY WORKING IN MINES MANY YEARSWORKERS COMP LETTER 4-27-93.
1992 · 2 incidents
MAKING BELT SPLICE 1 BELT LINE WHEN SMALL PIECE OF HAMMER STRUCK VICTIM ON LEFT EYE WHEN WATCHING MEN DRIVING STAPLES IN BELT VICTIM WAS NOT WEARING HIS GLASS. NOTE REINSTRUCTE MEN ON WEARING THEIR GLASS.
FALL ON FIRST LEF TOFF MAIN IDEAL SECTION. FALL IN NO.1 ENTRY LAST OPEN BREAK. FALL 20 FOOT LONG 5 FOOT WID E6 FOOT HIGH. NO PERSONS INVOLVE, NO EQUIPMENT INVOLFE, HAD WILD COAL AT THE ANGK ER POINT. SOME WATER IN ROOF.
1991 · 4 incidents
RF FALL HAD WET MATERIALS,IN WILD SEAM 5'H A2 TO 3' CROSS CUT 20'L 14FT W 14 FT H
RF FALL IN HOLLOW SEAM 5 FT H 14 FT L 14 FT W
ROOF FALL 3 ENTRY 20 F L 2F W 10 FH
PNEUMOCONIOSIS AWARD MAR 91
1990 · 2 incidents
ROOF FALL #2 ENTRY BELT LINE 2 BLOCKS FROM PIT MOUTH CHANGE IN WEATHER.
REMOVING STUCK DRILL STEEL FROM HOLE WHEN GLOVE CAUGHT ON DRILL STEEL CAUSING SMALL RT FINGER TO BE BROKEN
1989 · 1 incident
ROOF FALL ON NO 1 BELT TWO BLOCKS FROM OUTSIDE. LENGTH 30' LONG 14' WIDE 6' HIGH. MINE WAS IDLE OFF FOR CHRISTMAS. COLD WEATHER DRY OUT.
1987 · 4 incidents
ROOF FAL ON BEL7 2 NO PERSONS INVOLVED DURING NON WORK SHIFT
NO PERSONS OR E0UIP INVOLVED.ROOF SWEATING CAUSING FALL.SIZE OF FALL-20'LONG X 14'WIDE X 4'THICK.#1 OUTBY SUPPLY ROAD.
HOT WEATHER CAU8ING SWEATING. KNOW PERSON WAS INVOLVED IN FALL. KNOW EQUIPMENT INVOLVED IN FALL. FALL 14' WIDE 25 LONG 6' HIGH.
ROOF FALL IN #13ENTRY APPROXIMATELY 140 FEET.FALL AREA 25 FEET LONG, 12 FEET WIDE, 7 FEET HIGH.HAD 6 FOOT BOLTS RESIN BOLTING CROSS BARS 5" ? 7" ON MINE POST.
1986 · 3 incidents
ROOF FALL AT FA7E #3 ENTRY FELL AT T HE POINT OF ANCHOR SIZE OF FALL APPROX 30 FT LONG 25 FT WIFE AT THE BREAKING OF A CROSSCUT TO THE LEFT USING 6 FT RESIN ROOF BOLTS FALL FELL IN FRONT OF MINER NO DAMAGE3TO MACHINE ROOF F WAS ROTTEN HOT WEATHER CAUSING MOISTURE ON ROOF
ROOF FALL 2 ENT9Y FALL TOOK PLACE WHEN MINE WAS IDEAL. HOT WEATHER AND SWEATING. NO PERSON INVOLVED NO EQUIPMENT IVOVLED.
ROOF FALL HOT W3EATHER SWEATING NO PERSONS INVOLED NO EQUIPMENT 2 ENTRY.
1985 · 3 incidents
ROOF BOLTER WAS3INSTALLING BOLTS HAD THREE BOLTS LEFT TO INSTALL IN REMAINDING CUTWHEN ROOF FELL ROCK BROKE OFF UP TO THE ATRS & BOLTS THAT HAD BEEN INSTALLED ROCK STSRUCK THE BOLT MANON TH E RT HIP & RT F2OT BOLTMAN WAS BRUISED FROM FALLROCK
FALL IN #2 ENTRY AT INTERSECTION CROSSCUT FELL ABOVE ANGER OF 6\ FOOT RESIN BOLTS 14\ WIDE X 25\ LONG X.
FALL IN #1 ENTRY AT INTERSECTION CROSS CUT TO LEFT TOOK (A) RUN APPROX. 15\ FT. ROOF BOLTER STORTED BOLTING NOTICE SPITTING OF ROOF. WAS IN PROCESS OF REMOVING MACHINE FROM AREA, FALL FELL ON FRONT OF MACHINE. NOTE: (NO INURIES) NO DAMAGE TO MACHINE.
1983 · 5 incidents
ROOF FALL #4 ENTRY 2ND X-CUT FROM FACE- HOT WEATHER SWEATING- WAS USING 5\ BOLT NOW USING 6\ & 7\ BOLTS.
HOT WEATHER CAUSING SWEAT AND ROOF FALL WENT FROM 5FT RESIN BOLTS TO 6FT RESIN BOLTS NO PERSONS OR EQUIP INVOLVED
FOOF FALL NO 5 ENTRY OUTBY L.O.C. HOT WEA T HER CAUSING SWEATING USING 5\ RESIN BOLTS & 10\ STRAPS & ONE HOLE BOARDS WENT TO 6\ BOLTS NO DAMAGE TO EQUIPMENT OR PERSONS
ROOF FLL NO 1 ENTRY HOT WEATHER CAUSING SWEAT USING RESIN BOLTS & 10\ STRAPS & WITH ONE HOLE BOARDS WENT TO 6\ RESIN BOLTS STRAPS WITH ONE HOLE BOARDS NO DAMAGE TO EQUIPMENT OR PERSONS
ROOF FALL IN X-CUT #3 ENTRY.5\GHHIGH X 22\WIDE X 25\LONG.
The full compliance file on #1
A dated report covering the 26-year penalty trail, line-item violation pattern, contest and docket posture, rate-normalized peer benchmark, and full fatality history. Delivered as a PDF with the underlying data as CSV.