OUTCROP MINING. WATER IN TOP OF ROOF FALL.
#3 Punch Mine: 12 reportable incidents Coal
MSHA record for #3 Punch Mine (mine ID 1517653). Fatalities, non-fatal incidents grouped by year, current operator and controller, and mine context.
Watch this mine
Email me when a new MSHA incident is filed at #3 Punch Mine.
- Fatalities
- 0
- Total incidents
- 12
- Years on record
- 1996–1999
- Latest incident
- Apr 1999
- Midnight Coal Corp 1995 to 1995
- Gemco Energies Inc 1995 to present
#3 Punch Mine sits in Knott County, Kentucky, where the Census mining category is 2.8% of county employment.
ⓘ
County figures come from the US Census Bureau's American Community Survey, 5-year pooled estimates, so the 2023 vintage covers 2019 through 2023. The Census category is 'mining, quarrying, and oil and gas extraction', which is broader than MSHA jurisdiction and includes oil and gas workers no mine employs. These figures describe the surrounding county, not this mine, and are not a factor in any specific incident.Reportable incidents
12 on file1999 · 3 incidents
THE ENTRY HAD DEVELOPED WATER IN THE ROOF CAUSING THE SHALE TOP TO WEAKEN. IT WAS IN THE INTAKE #8 ENTRY, 1900 UNDERGROUND. VENTILATION IS NOT INTERUPTED.
THE AREA IN THE RETURN HAD BEEN CRIBBED OFF FOR 1 MONTH. THE ROOF WAS WET AND TEST HOLES SHOWED A 4' CRACK. IT FELL BETWEEN THE CRIBS BETWEEN #1 & #2 RETURN. #3 VENTILATION IS NOT RESTRICTED.
1998 · 4 incidents
HE SAID HE WAS HANGING CABLE ON MINER. WHEN HE GOT HIS FOOT UNDER MINER DECK. RIGHT FOOT.
WATER DEVELOPED IN TOP ON FIRST RT OFF #5 BELT. FELL IN #1 ENTRY AT FACE. 80 FT LONG, 5 FT HIGH, AND #4 + #3 ENTRIES ROOM NECKS #4 + #3 ABOUT 35 FT LONG 5 FT HIGH. HAD PULLED OFF SECTION FOR WEEK AND 1/2.
WATER DEVELOPED IN TOP.THE FALL OCCURRED OUTBY SPAD 562,ON H LEFT PANEL FROM 0 TO 80' LONG FROM O TO 20' WIDE.6' HIGH.WHILE MAKING RETURN FOUND A NADISHANLA FALL ON 4 LEFT PANEL 40' BY20' SECO ND OPEN X CUT.IN #2 ENTRY 4'4"HIGH. WATER IN TOPOF COAL SEAM.
WATER DEVELOPED IN THE TOP OF THE FALL OCCURRED IN SECTION 4L OFF #4 MAIN IN THE RETURN. VENTILATION WAS NOT DISTURBED.
1997 · 1 incident
EE WENT TO HIS SHUTTLE CAR AS HE STARTED TO MOUNT THE MACHINE, HIS FOOT ACCIDENTLY STRUCK THE POWER FEED, THE MACHINE ROLLED F0RWARD PINNING HIM BETWEEN THE MACHINE & RIB
1996 · 4 incidents
SMALL COAL SEAM ABOVE FALL.
CROSSCUT #23 IN #4 ENTRY. HAD 1 HILLSEAMS ON AN ANGLE ACROSS INTERSECTION. TIMBER WAS USED.
DOEN SOMETHING TO HIS KNEE WHLE HANGING CURTAINS.
HORSE'S BACKS IN & NEAR WHERE ROCK FALL IS. FALLOCCURRED IN INTERSECTION #15 IN #5 ENTRY. DIDNOTRESTRICT IN AIR.