A ROOF FALL WAS FOUND BY THE PRE-SHIFT MINE EXAMINER ON 6-20-05. THE LOCATION WAS 1 BLOCK INBY SPAD 31, IN #2 ENTRY. THE FALL OCCURRED OVER A WEEKEND. THE WIDTH 16', LENGTH 65', HEIGHT 6' TO 7'. DATE OF DEVELOPMENT 8-02. ROOF SUPPORT 6' FULLY GROUTED RESIN BOLTS WITH STRAPS. IN A 4 WAY INTERSECTION. THE FALL WILL NOT BE CLEANED UP.
Fairmont Energy Mine #2Coal
- Fatalities
- 0
- Total incidents
- 22
- Years on record
- 2002–2005
- Latest incident
- Jun 2005
Reportable incidents
22 on file2005 · 3 incidents
EE was taking a belt pin out using two hammers. When he hit one hammer against the other a piece of hammer (steel) came off and went into his left hand above the thumb.
EE WAS MOVING CABLES. HIS RIGHT LEG GOT CAUGHT IN THE MUD. WHEN HE PULLED HIS LEG OUT OF THE MUD HE SPRAINED HIS RIGHT KNEE. ON 5/2/05 HE HAD TO HAVE SURGERY ON HIS RIGHT KNEE.
2004 · 6 incidents
A PILLAR FALL OCCURRED WHILE BACKING THE CONTINUOUS MINER OUT OF THE SECOND PILLAR SPLIT OF THE NO.10 PILLAR BLOCK, COVERING UP THE HEAD OF THE MINER. THE LENGTH, WIDTH & THICKNESS COULD NOT BE DETERMINED. THE FALL WAS IN THE NO. 10 ENTRY, 3 BLOCKS INBY STATION NO.219.
EMPLOYEE WAS OPERATING THE FLETCHER ROOF BOLTER. WHILE BACKING UP TO GO INTO ANOTHER FACE, HE PINCHED HIS RIGHT LEG AND FOOT BETWEEN THE ROOF BOLTER AND THE JOY SHUTTLE CAR. HE WAS IN THE DECK OF THE BOLTER WITH HIS RIGHT LEG ON THE BUMPER.
A roof fall was found at 11:00 am on 6-9-04 in an idle entry 001 north mains. The fall will not be cleaned up. It was 18' wide 45' long 8' high. fully grouted resin bolts with 11' straps.
EMPLOYEE WAS WALKING BY THE POWER CENTER OF THE SECTION. HE SLIPPED ON THE BELT MAT AT THE POWER CENTER, SPRAINING HIS RIGHT KNEE. HE DID NOT GO TO THE DOCTOR UNTIL 6/11/04.
EE WAS STEPPING INTO THE SCOOP BUCKET TO HOOK UP A CHAIN WHEN HE PULLED HIS LEFT KNEE.
A ROOF FALL WAS FOUND ON #1 BELTLINE AT SPAD NO. 14 IN A 4-WAY INTERSECTION. IT WAS 18 FT WIDE, 26 FT LONG, 10 FT HIGH. THE ROOF SUPPORT IN THIS AREA WAS 6' FULLY GROUTED RESIN BOLTS WITH CROS SBARS. DATE DEVELOPED WAS MAY 2002.
2003 · 6 incidents
EE WAS REPAIRING THE CONVEYOR CHAINS ON THE MINER, WHEN HE HIT HIS LIFT FOOT WITH A SLEDGE HAMMER.
EE BENT OVER TO MOVE THE MINER CABLE OUT OF THE SHUTTLE CAR ROADWAY, WHEN HE PICKED THE CABLE UP HE PULLED A MUSCLE IN HIS LOWER BACK.
EE WAS CHECKING A HYD. HOSE THAT HE HAD TIGHTENED ON THE 488 S&S SCOOP. HE HAD TO BEND OVER AND LOOK INSIDE TO SEE IF IT WAS LEAKING. WHEN HE TURNED THE SCOOP ON AND PUSHED THE LEVER A HYD. HO SE BESIDE IT BLEW UP IN HIS FACE, AND GOT DIRT AND METAL IN HIS LEFT AND RIGHT EYES.
EE WAS TYING A PLUM-BOB TO A ROOF SPAD. A PIECE OF ROCK 3' X 3' X 1' FELL FROM BETWEEN ROOF BOLTS. IT STRUCK THE EE ON THE BACK HIS HEAD & HIS BACK.
THERE WAS A ROOF FALL IN THE PITMOUTH OF THE #3 HEADING, WHICH IS THE FAN ENTRY, THE FALL WAS 15FOOT LONG, 1'WIDE & 6'HIGH. THIS AREA WAS MINED 3/2002, IT WAS SUPPORTED WITH 6'FULLY GROUTED RESIN BOLTS, AND CROSSBAR. THE FALL WAS CLEANED UP.
AT 1:30 P.M. ON 2/12/03 A ROCK SLID DOWN OFF THE HIGHWALL AND KNOCKED OUT THE CANOPY IN #4 ENTRY. THIS ROCK WILL BE CLEANED UP AND AN ARCH SET INSTALLED.
2002 · 7 incidents
ROOF FALL IN THE #1 ENTRY AT SPAD NO. 57 IN THE EAST MAINS SECTION. FALL WAS 7' HIGH, 16' WIDE & 5' LONG. SUPPORTED WITH 6' FULLY GROUTED RESIN BOLTS WITH 11' STRAPS.
EMPLOYEE WAS OPERATING A SHUTTLE CAR ON THE MAIN SECTION WHEN HE GOT DUST IN HIS RIGHT EYE. HIS EYE WAS WASHED OUT THE SAME DAY AT THE HOSPITAL. ON 11/11/02 HE WENT BACK TO THE HOSPITAL. THEY SENT HIM TO A DOCTOR WHO TREATED HIS EYE INFECTION. HE DID NOT MISS WORK UNTIL 11/11/02.
AT 1:00 PM ON 10/13/02 A ROCK SLID DOWN OFF THE HIGHWALL AND KNOCKED OUT THE RIGHT WASS OF THE #4 ENTRY CANOPY. THE ROCK WAS CLEANED UP AND CANOPY REBUILT.
A ROOF FALL WAS FOUND ON THE FIREBOSS RUN IN A 4WAY INTERSECTION, 16' WIDE, 10' HIGH, 60' LONG. IT WAS BOLTED WITH 6' FULLY GROUTED RESIN BOLTS. NO DAMAGE TO REPORT.
EE ALLEGES STEPPED IN HOLE AND TWISTED RT. KNEE.
A ROOF FALL WAS FOUND ON 5-28-02 AT 5:33 AM BY THE FIREBOSS. IT IS NOT KNOWN WHEN THE FALL OCCURRED. THE FALL WAS 16' WIDE, 25' LONG, 18' HIGH. IN A 3WAY INTERSECTION. 6' & 7'3/4"" RESIN BOLTS WERE INSTALLED IN THIS AREA. ALSO 3"" X 8"" X 16' CROSSBARS. THE FALL WILL BE CLEANED UP.
FAIRMOST ENERGY MINE #2 WAS STARTING. PITMOUTH UNDERGROUND. THE PITMOUTH FOR THE #3 ENTRY WAS IN THE HIGHWALL 15' AND 5-5' ROOF BOLTS HAD BEEN INSTALLED WITH 3-6"" H BEAM, INSTALLEN. THE HIGHWA LL FELL IN TAKING OUT THE 5 ROOF BOLTS AND THE 3-6"" H-BEAM.